Use and Care Manual

HE240, HE280 HUMIDIFIER
69-2685ES—07 14
F
ig. 20. Cleaning your humidifier.
End of Humidification Season
Clean the humidifier and shut it off at the end of the heating season.
Turn the water off at the shut off valve.
Turn the H6062 to off.
Turn the damper blade to the "summer" position.
IMPORTANT
Be sure the humidifier power is off.
Replacement Humidifier Pads
It is recommended to replace the humidifier pad on an annual basis. However, if your home has hard water, the
pad may need to be replaced more frequently because of the buildup of minerals diminishing its ability to
operate normally. If there is access to a water softener, it is recommended to use softened water.
Vacation
When leaving on vacation, turn off the humidifier water supply and your humidistat.
When you return, turn on the humidifier water supply and reset your humidistat.
Start of the Humidification Season
Use the following steps to bring the humidifier back to normal (winter) operation:
1. Turn damper blade to "winter" position.
2. Plug the humidifier transformer back into wall outlet and turn water supply to the humidifier back on at
shut off valve.
3. Turn the humidistat to its highest setting and set the thermostat to 10 °F (6 °C) above the room
temperature.
4. Observe that water is flowing out of the drain hose.
Table 3. Replacement pad part numbers.
Humidifier Model Replacement Pad
HE240 HC22P
HE280 HC26P
M33328A
PerfectFLO™ WATER
DISTRIBUTION TRAY
HUMIDIFIER PAD ASSEMBLY
WATER FEED NOZZLE
HUMIDIFIER HOUSING
SIDEWALL
BYPASS
SIDEWALL
COVER
WATER FEED TUBE