Troubleshooting
If you have difficulty with your thermostat, please try the following suggestions. Most 
problems can be corrected quickly and easily.
Display is blank  •  Check circuit breaker and reset if necessary.
•  Make sure power switch for heating & cooling system is on.
•  Make sure furnace door is closed securely.
•  Make sure the C wire is connected.
Heating or 
cooling system 
does not 
respond
•  Press Menu > System Mode > Heat > Done to set the system 
to Heat mode. Make sure the desired temperature is higher 
than the indoor temperature.
•  Press Menu > System Mode > Cool > Done to set the system 
to Cool mode. Make sure the desired temperature is lower 
than the indoor temperature.
•  Check circuit breaker and reset if necessary.
•  Make sure power switch for heating & cooling system is on.
•  Make sure furnace door is closed securely.
•  Wait 5 minutes for the system to respond.
Temperature 
settings do not 
change
Make sure desired temperature is within acceptable ranges:
•  Heat: 40 °F to 90 °F (4.5 °C to 32.0 °C)
•  Cool: 50 °F to 99 °F (10.0 °C to 37.0 °C)
Aux heat runs in 
cooling
•  For heat pump systems, verify there is not a wire attached to 
W on the UWP. 
Cool runs with a 
call for heat
•  For heat pump systems, verify there is not a wire attached to 
W the UWP.
Sensor will not 
connect
•  Press and hold Connect on the wireless sensor for 15 
seconds. The LED will turn Amber. Return to the thermostat 
menu and press Menu > Devices and Sensors. Follow the on-
screen instructions to add the sensor.