Selection Guide
Connected Thermostats
Description Model Schedule Options
User
Interface
Application
Power
Method
Features and Functions
Service
Reminders
Limited
Warranty
Wiring
Terminals
Accessories
Included
Network
Connection
Program Options
Temporary Override
Permanent Hold
Vacation
Hold
Stages
Gas, Oil or Electric
Heat Pump
Millivolt
Linevolt
Selectable Residential
and Light Commercial
Duel fuel
Balance Point
Lockout
Upstage Timer &
Droop Settings
Humidification
Control
Dehumidification
Control
Ventilation Control
Demand Response
Permanent Memory
Retention
Selectable Auto or
Manual Changeover
Auxillary Heat
Lockout
Adaptive Intelligent
Recovery
Temperature
Setpoint Limits
Keypad Lockout
Programmable &
Circulation Fan
Tri-Lingual
Language Options
Wireless Outdoor
Sensor
Wired Outdoor Sensor
Wired Indoor Sensor
Wireless Indoor Temp/
Hum Sensor
Wireless Indoor
Motion Sensor
Dealer Info On Screen
Display Size
( Viewable)
Continuous
Backlighting
Filter, Humidifier Pad,
UV Lamp Replacement
Reminders
WIFI
T10 Pro Smart with
RedLINK® Sensor
THX321WFS2001W
Geofence, 7day, 1
week, no schedule
. • •
Through app Touchscreen
Up to 3 Heat/2 Cool – Heat Pump
Up to 2 Heat/2 Cool – Conventional
• • • • • • • •
CWire
• • • • • • • • •
Via
internet
• • • • •
7.27 sq. in.
• •
5 Year R, RC, C, W, W2AUX, E, 0/B, Y, Y2, G, L, K, U, U, S and S
C7189R2002 wireless temp/humidity/motion sensor, UWP
mounting system, decorative cover plate, & mounting hardware
T10 Pro Smart
without Sensor
THX321WF2003W
UWP mounting system, decorative cover plate, & mounting
hardware
T6 Pro Smart
TH6320WF2003
Geofence, 7-day,
511, 52, 1 week,
no schedule
• •
Through app Touchscreen
Up to 3 Heat/2 Cool – Heat Pump
Up to 2 Heat/2 Cool – Conventional
• • • • • •
CWire
• • • • • • • •
Via
internet
Lockouts
only, no
display
•
6.89 sq. in.
• •
5 Year R, RC, C, W, W2AUX, E, 0/B, Y, Y2, G, L, K, U, U, S and S
UWP mounting system, decorative cover plate, & mounting
hardware
TH6220WF2006
Geofence, 7-day,
511, 52, 1 week,
no schedule
• •
Through app Touchscreen
Up to 2 Heat/1 Cool – Heat Pump
Up to 2 Heat/2 Cool – Conventional
• • • •
CWire
• • • • • • • •
Via
internet
Lockouts
only, no
display
•
6.89 sq. in.
• •
5 Year R, RC, C, W, W2AUX, E, 0/B, Y, Y2, G, L, K, S and S
UWP mounting system, decorative cover plate, & mounting
hardware
9000 Smart
TH9320WF5003 7Day or NP
• • •
Touchscreen
Up to 2 Heat/2 Cool – Heat Pump
Up to 2 Heat/2 Cool – Conventional
• • •
CWire
• • • • • • • •
Via
internet
8 sq. in.
•
Filter, humidifier
pad only
5 Year R, RC, C, W0/B, Y, G, W2AUX/E, Y2, L, K Mounting hardware
Vision PRO®
8000 Smart
TH8321WF1001 7Day or NP
• • •
Touchscreen
Up to 3 Heat/2 Cool – Heat Pump
Up to 2 Heat/2 Cool – Conventional
• • • • • • • • •
CWire
• • • • • • • •
Via
internet
• • •
10 sq. in.
• •
5 Year
R, RC, W2AUX/E, Y, Y2, G, C, K, S1, S1, W0/B, U1, U1, AL/A
Mounting hardware
Via RedLINK Internet Gatway
Prestige® IAQ Kits
YTHX9421R5085WW 7Day or NP
• • •
Touchscreen
Up to 4 Heat/2 Cool – Heat Pump
Up to 3 Heat/2 Cool – Conventional
• • • • • • • • • •
24 volt to R and C at
thermostat and EIM
w/
Gateway
• • • • • • • • • • • • •
8 sq. in.
• •
5 Year
Prestige IAQ - R, C. Equipment Interface Module - R, C, RH,
RC, WO/B, W2/AUX1, W3/AUX2, Y, Y2, G, AL/A, U1, U1,
U2, U2, U3, U3, S1, S1, S2, S2, S3, S3, S4, S4 A, B, C, D
THM5421R1021 Equipment Interface Module
and 2 duct sensors
YTHX9421R5101WW 7Day or NP
• • •
Touchscreen
Up to 4 Heat/2 Cool – Heat Pump
Up to 3 Heat/2 Cool – Conventional
• • • • • • • • •
24 volt to R and C at
thermostat and EIM
w/
Gateway
• • • • • • • • • • • • •
8 sq. in.
• •
5 Year
Prestige IAQ - R, C. Equipment Interface Module - R, C, RH,
RC, WO/B, W2/AUX1, W3/AUX2, Y, Y2, G, AL/A, U1, U1,
U2, U2, U3, U3, S1, S1, S2, S2, S3, S3, S4, S4 A, B, C, D.
THM5421R1021 Equipment Interface Module, C7089R1013
wireless outdoor sensor, and 2 duct sensor
YTHX9421R5127WW 7Day or NP
• • •
Touchscreen
Up to 4 Heat/2 Cool Heat Pump
Up to 3 Heat/2 Cool Conventional
• • • • • • • • • •
24 volt to R and C at
thermostat and EIM
• • • • • • • • • • • • • •
8 sq. in.
• •
5 Year
Prestige IAQ - R, C. Equipment Interface Module - R, C, RH,
RC, WO/B, W2/AUX1, W3/AUX2, Y, Y2, G, AL/A, U1, U1,
U2, U2, U3, U3, S1, S1, S2, S2, S3, S3, S4, S4 A, B, C, D.
THM5421R1021 Equipment Interface Module,
THM6000R7001 RedLINK Internet Gateway and
2 duct sensors
YTHX9421R7001WW 7Day or NP
• • •
Touchscreen
Up to 4 Heat/2 Cool Heat Pump
Up to 3 Heat/2 Cool Conventional
• • • • • • • • • •
24 volt to R and C at
thermostat and EIM
• • • • • • • • • • • • • •
8 sq. in.
• •
5 Year
Prestige IAQ - R, C. Equipment Interface Module - R, C, RH,
RC, WO/B, W2/AUX1, W3/AUX2, Y, Y2, G, AL/A, U1, U1,
U2, U2, U3, U3, S1, S1, S2, S2, S3, S3, S4, S4 A, B, C, D.
THM5421R1021 Equipment Interface Module,
THM6000R7001 RedLINK Internet Gateway, C7089R1013
wireless outdoor sensor, C7189R1004 wireless indoor sensor
and 2 duct sensors
Prestige®IAQ
THX9421R5021WW 7Day or NP
• • •
Touchscreen
Up to 4 Heat/2 Cool Heat Pump
Up to 3 Heat/2 Cool Conventional
• • • • • • • • • •
24 volt to R and C at
thermostat and EIM
w/
Gateway
• • • • • • • • • • • • •
8 sq. in.
• •
5 Year Prestige IAQ - R & C. (EIM ordered separately). Mounting hardware
EConnect™ Wireless
Comfort System
YTL9160AR1000 7Day or NP
• •
Soft Keys 1 Heat
•
Battery powered thermo-
stat, 120/240V at EIM
• • • •
4.53 sq. in. 3 Year L1/L, L2/N & Load, Load Antenna (with 2 covers white and beige) and EIM
RedLINK®
VisionPRO® 8000
TH8110R1008
7Day or NP
• • •
Touchscreen 1 Heat/1 Cool**
• • • •
Dual powered
(battery and hardwire)
w/
Gateway
• • • • • • • • • • •
10 sq. in.
• •
5 Year
R, RC, C, WO/B, Y, G, K, S1, S1
Batteries & mounting hardware
TH8320R1003
7Day or NP
• • •
Touchscreen
Up to 3 Heat/2 Cool – Heat Pump
Up to 2 Heat/2 Cool – Conventional*
• • • • • • •
Dual powered
(battery and hardwire)
w/
Gateway
• • • • • • • • • • • •
10 sq. in.
• •
5 Year R, RC, C, WO/B, W2AUX/E, Y, Y2, G, AL/A, K, S1, S1 Batteries & mounting hardware
TH8321R1001 7Day or NP
• • •
Touchscreen
Up to 3 Heat/2 Cool – Heat Pump
Up to 2 Heat/2 Cool – Conventional*
• • • • • • • • • •
Dual powered
(battery and hardwire)
w/
Gateway
• • • • • • • • • • • •
10 sq. in.
• •
5 Year
R, RC, C, WO/B, W2AUX/E, Y, Y2, G, AL/A, K, U1, U1, S1, S1
Batteries & mounting hardware
YTH8321R1002 7Day or NP
• • •
Touchscreen
Up to 3 Heat/2 Cool – Heat Pump
Up to 2 Heat/2 Cool – Conventional*
• • • • • • • • • •
Dual powered
(battery and hardwire)
• • • • • • • • • • • • •
10 sq. in.
• •
5 Year
R, RC, C, WO/B, W2AUX/E, Y, Y2, G, AL/A, K, U1, U1, S1, S1
RedLINK Internet Gateway, Batteries & mounting hardware
FocusPRO® 6000
RedLINK®
Programmable Kit
YTH6320R1001
511/52
• •
Soft Keys
Up to 3 Heat/2 Cool – Heat Pump
Up to 2 Heat/2 Cool – Conventional*
• • • • •
Batteries at thermostat.
R and C at EIM
• • • • • •
5.09 sq. in. 5 Year
Equipment Interface Module – C, R, RC, RH, WO/B, W2AUX
/E, Y, Y2, G, L, RAS, RAS
EIM, Return Air Sensor, Batteries & mounting hardware
FocusPRO® 5000
RedLINK®
NonProgrammable
YTH5320R1000
Non
programmable
Soft Keys
Up to 3 Heat/2 Cool – Heat Pump
Up to 2 Heat/2 Cool – Conventional*
• • • • • •
Batteries at thermostat.
R and C at EIM
• • • • •
5.09 sq. in. 5 Year
Equipment Interface Module – C, R, RC, RH, WO/B,
W2AUX/E, Y, Y2, G, L, RAS, RAS
EIM, Return Air Sensor, Batteries & mounting hardware
Z-Wave
T6 Pro ZWave TH6320ZW2003
7Day, 511,
52, 1 week no
schedule, ZWave
occupancy
• •
Through
ZWave app
Touchscreen
Up to 3 Heat/2 Cool – Heat Pump
Up to 2 Heat/2 Cool – Conventional*
• • • • •
Dual powered
(battery and hardwire)
• • • • • • • • •
6.89 sq. in.
• •
5 Year C, R, RC, Y, Y2, G, 0/B, W, W2, AUX, E, L, K, S and S
UWP mounting system, decorative cover plate, & mounting
hardware