Removable Duct Collars
Spendlesstimeontheladderbyeasilyconnectingtheductwork
to the collars away from the unit before it’s hung, and then sliding
thecollarsbackintoplaceonceducted.
Intuitive Balancing
Twovariable-speedmotors—oneforeachairstream—work
with the integrated speed control so installers can adjust the
speed of each motor up and down to easily balance the system.
This eliminates the need for adjusting dampers.
Wall Mount Bracket
Justliketighteningorlooseningstrapsonabackpack,these
strapsmakeiteasytoraise,lowerandleveltheunitintoplace
Ventilation Performance VNT5150E
External Static Pressure Net Supply Air Flow
Pa in w.c. L/s CFM
25 0.1 49 105
50 0.2 46 97
75 0.3 44 92
100 0.4 37 80
125 0.5 34 73
150 0.6 29 62
175 0.7 23 48
200 0.8 22 46
Push Through—Operation System
Outside air is pushed through the heat exchanger, which acts as
a noise reducer. This process is very silent and provides you with
better home comfort.
Proportional Defrost—Operation System
The defrost energy is controlled by the outdoor air temperature.
The motor speed essentially increases as outdoor temperature
drops to provide increased defrost capability.
2 in 1 Ventilation Hood Accessory
WARNING: Installation must be performed by a quali-
fied service technician and must comply with local
codes. Remove power to the device before installing
or servicing the device. Failure to connect the device
according to these instructions may result in damage
to the device or the controls.
Energy Performance VNT5150E
Supply Temperature Net Supply Air Flow Average Power Sensible Recovery Apparent Sensible
°C °F L/s CFM Watts Efficiency (%) Effectiveness (%)
Heating
0 32 20 41 30 65 74
0 32 30 64 36 64 71
-15 5 16 35 27 54 80
Cooling
35 95 19 41 75
Total Recovery Efficiency = 43%
VNT5070E1000
AIR FLOW (L/S)
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
050 100 150
0
25
50
75
100
125
150
175
225
01020
AIR FLOW (CFM)
EXTERNAL
STATIC
PRESSURE
(IN. W. C)
EXTERNAL
STATIC
PRESSURE
(PA)
M33684
0.9
200
30
40
50
60
Exhaust Air
To Outside
Fresh Air
From Outside
Fresh Air
To Home
Exhaust Air
From Home