Brochure

ZONING PRODUCTS CATALOG
3 70-0851—17
WHAT YOU NEED...
Zone panel kit page 4 + a thermostat for each zone pages 5-8 + zone damper page 8-10 + by-pass damper pages 11-12 +
accessories (optional) page 6.
ZONING CONTROL PANEL SELECTION GUIDE
* It is recommended to set the zone panel high limit approx. 15°F below the furnace high limit. Some modern furnaces
have low high limit settings, so make sure the correct zone panel is selected for the equipment. The HZ311 zone panel
has a fixed high limit (160°F). The HZ322 & HZ432 zone panels have adjustable high limit (110°F-180°F).
APPLICATION
CONVENTIONAL
1-HEAT/1-COOL
HEAT PUMP WITH SINGLE
STAGE COMPRESSOR AND
ELECTRIC AUXILIARY HEAT
STAGE
•GAS FURNACE WITH 2
HEAT
•STAGES AND 2 COOL
STAGES
•HEATPUMP WITH 2
COMPRESSOR STAGES AND
NO AUXILIARY HEAT
•HEATPUMP WITH 1
COMPRESSOR STAGE +
AUXILIARY HEAT
HYDROAIR HEAT
HEATPUMP WITH 2
COMPRESSOR STAGES +
AUXILIARY HEAT
DUAL FUEL HEATPUMP
WITH 1-2 COMPRESSOR
STAGES + 1-2 FURNACE
STAGES
•3 CONVENTIONAL HEAT
STAGES + 1-2 COOL
STAGES
2 Zones. Wired Thermostats HZ311K* HZ221K (Heatpump thermostats
with O wire only. For conventional
thermostats or heatpump
thermostats with B changeover,
use HZ322K.)
HZ322K HZ432K (C7089U1006 wired
outdoor sensor needed for dual
fuel)
3 Zones. Wired Thermostats HZ311K* HZ322K HZ322K HZ432K (C7089U1006 wired
outdoor sensor needed for dual
fuel)
4 Zones HZ432K HZ432K (C7089U1006 wired
outdoor sensor needed for dual
fuel)
2-3 Zones Wireless Zoning
with TH6320R or TH5320R
RedLINK Wireless Thermostats
HZ322K + THM4000R adapter HZ432K + THM4000R adapter
(C7089R1013 wireless outdoor
sensor needed for dual fuel)
4 Zones Wireless Zoning with
TH6320R or TH5320R RedLINK
Wireless Thermostats
HZ432K + THM4000R adapter
2-3 Zones Wireless Zoning with
TH8110R, TH8320R, or
TH8321R RedLINK Wireless
Thermostats
HZ322K + THM4000R adapter.
(Cannot do remote scheduling when THM4000R and THM6000R gateway are used. TH8321R loses IAQ
control when used with THM4000R)
HZ432K + THM4000R
adapter.
(TH8110R, TH8320R, and
TH8321R models can do remote
scheduling when wired to the
panel. These models cannot do
remote scheduling when
THM4000R and THM6000R
gateway are used. TH8321R loses
IAQ control when used with
THM4000R). (C7089R1013
wireless outdoor sensor needed
for dual fuel)
4 Zones Wireless Zoning with
TH8110R, TH8320R, or
TH8321R RedLINK Wireless
Thermostats
HZ432K + THM4000R adapter.
(Cannot do remote scheduling when THM4000R and THM6000R gateway are used. TH8321R loses IAQ
control when used with THM4000R)