Brochure

ZONING PRODUCTS CATALOG
70-0851—17 4
TRUEZONE ZONING KITS
TrueZONE Zoning kits make ordering and stocking easy. All kits include a zone panel, transformer, and discharge air
temperature sensor.
HZ432K 2-4 Zone Panel Kit
(Includes one HZ432 panel, one transformer, and one C7735A discharge air temperature sensor.)
HZ322K 2-3 Zone Panel Kit
(Includes one HZ322 panel, one transformer and one C7735A discharge air temperature sensor.)
HZ311K 2-3 Zone Panel Kit
(Includes one HZ311 panel, one transformer and one C7735A discharge air temperature sensor.)
NOTE: It is recommended to set the zone panel high limit approx. 15°F below the furnace high limit. Some modern fur-
naces have low high limit settings, so make sure the correct zone panel is selected for the equipment. The HZ311
zone panel has a fixed high limit (160°F). The HZ322 & HZ432 zone panels have adjustable high limit (110°F-
180°F).
HZ221K 2 Zone Panel Kit
(Includes one HZ221 panel, one transformer and one C7735A discharge air temperature sensor.)
Compatibility and features:
1 stage heat + 1 stage cooling conventional (gas or oil furnace).
2 stage gas furnace and/or 2 stage air-conditioning.
Heatpump with 1 or 2 compressor stages + auxiliary electric back up.
Dual fuel Heatpump with 1 or 2 compressor stages + 1 or 2 stages gas or oil furnace back up
using wired sensor C7098U or wireless outdoor sensor C7098R + THM4000R wireless adapter.
Hydro-air applications.
RedLINK enabled with THM4000R Wireless Adapter, and RedLINK wireless thermostats on
2-4 zone systems.
Intuitive Installer setup. Easy-to-follow, digital display uses real language to guide installer
through four easy steps.
Standard Checkout Procedure.
Robust Push Terminals.
Variable-Speed Fan Control.
Compatibility and features:
1 stage heat + 1 stage cooling conventional (gas or oil furnace).
2 stage gas furnace and/or 2 stage air-conditioning.
Heatpump with 1 compressor stage + auxiliary electric back up.
Heatpump with 2 compressor stages + no auxiliary electric back up.
Hydro-air applications.
Intuitive Installer setup. Easy-to-follow, digital display uses real language to guide installer
through four easy steps.
RedLINK enabled with THM4000R Wireless Adapter and RedLINK wireless thermostats.
Universal Application.
Standard Checkout Procedure.
Robust Push Terminals.
Variable-Speed Fan Control.
Compatibility and features:
1 stage heat + 1 stage cooling conventional (gas or oil furnace).
Hydro-air applications (only if thermostats use G wire and can be set to energize fan in heat
mode).
Robust Push Terminals.
Common-Sense LEDs.
Clean, Professional Installation.
Variable-Speed Fan Control.
Compatibility and features:
Heatpump with 1 compressor stage + auxiliary electric back up.
Compatible only with heatpump thermostats with an O wire for cool changeover.
Robust Push Terminals.
Common-Sense LEDs.
Variable-Speed Fan control.
Only compatible with heatpump thermostats that use “O”.