9 | WMPR MOUNTING
The WMPR is intended to be mounted to a Din-Rail or mounted
via the mounting plate.
9.1 | Din-Rail Mounting
The WMPR DIN-Rail bracket is supplied with the WMPR and can
be “snapped” on to a 35mm DIN-RAIL.
Figure 58. Limitless™ WMPR DIN-RAIL bracket
9.2 | Tab Mounting
The WMPR has four tabs mounting holes intended to allow
mounting with a #8 style screw. As there are many types of screw
fasteners, care should be taken to not overtighten the fastener.
Also, ensure that the housing is being mounted on a flat surface.
Figure 59. Limitless™ WMPR Mounting Plate
10 | INSPECTION AND MAINTENANCE
10.1 | WMPR Inspection and Replacement
Periodic inspection
• Check the WMPR housing and connectors for signs of dam-
age. Replace if necessary
• Check the condition of the LCD display for signs of cracking
or damage. Replace WMPR if necessary
• Check the proper operation of the Function Buttons and if
found non-functional, replace WMPR
10.2 | Antenna Inspection and Replacement
• Check antenna or cable connection to WMPR connector to
ensure it is tight and bear no signs of damage or corrosion.
Replace if necessary per Section 8.