Use Instructions Part 15

N7674-3 4/05 PRELIMINARY
Honeywell International Inc.
5804AP
WIRELESS KEY
TRANSMITTER
INSTALLATION INSTRUCTIONS
For use with QED control panels ONLY!
GENERAL INFORMATION
The 5804AP is a compact, 4-button portable
wireless transmitter intended for use only
with wireless alarm systems that support
QED 5800AP series receivers. Each button
on the transmitter may be programmed for
any zone response, but is typically used for
arming, disarming, panic, and relay
activation. Each button's response is
assigned when programming the transmitter
at the control (see the QED control's
installation instructions).
The 5804AP is powered by two replaceable
lithium batteries designed to provide up to 4
years of life. For battery installation, see
Battery Access.
PROGRAMMING THE 5804AP
Each 5804AP is assigned a unique serial
number during manufacture. Each button on
the unit also has a distinct "loop" number
(refer to Figure 1 that you must programme
into the QED control panel during
installation. Assign each button to an
individual zone and designate the Input Type
as "BR" (Button Type RF). You must
program the lower left-hand button (Loop 4;
see Figure 1). If it is not programmed, a
"check" condition will occur when the button
is accidentally pressed.
You can also program the unit by entering
the serial number manually through a
keypad or by downloading it to the control
panel using Ademco's V-LINK Downloading
Software (Rev. 4 or higher). If you use one of
these methods, be sure to include the loop
number of each button (see Figure 1).
For complete details on how to program the
5804AP transmitter's serial number at the
control panel, see the QED control unit's
installation instructions.
Note: Buttons on this transmitter must be
pressed for at least 1/2 second to activate the
transmitter. This feature minimizes the
possibility of accidental transmissions.
YOU MUST
PROGRAMME
THIS BUTTON
LOOP 3
LOOP 1
LOOP 2
LOOP 4
Figure 1: 5804AP showing button designations
If you choose not to use the lower left-hand
button (Button 4), do the following:
1. Program it into the system anyway (see
previous explanation).
2. After the serial number has been
programmed, re-enter Zone Programming
for that zone.
3. At the "Zone Type" prompt, enter 00 and
press [*]. On VISTA 20/4111XM panels,
the system will ask whether you want to
permanently delete that zone. Enter 0
(No). This will cause the system to retain
the serial number, but render the button
inactive. On 4140XMPT2/VISTA-120
panels and above, continue to press [*]
until you see the "Enter Zone No?"
prompt. At this point, press 00 and [*].
Then enter *99 to exit program mode.
INSTALLING ADHESIVE LABELS AND
BUTTONS
The 5804AP is supplied with colored buttons
(red and blue) and colored adhesive
identification labels (blue, red, gray, and
green). Each label has a specified command

Summary of content (2 pages)