Preliminary Draft Xenon™ 1900/1902 Area-Imaging Scanner User’s Guide ™
Preliminary Draft Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
Preliminary Draft Product Agency Compliance - Xenon 1900 USA FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules.
Preliminary Draft Canada Industry Canada ICES-003 This Class B digital apparatus complies with Canadian ICES-003. Operation is subject to the following conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Conformité à la règlementation canadienne Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada.
Preliminary Draft In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems for product disposal. Those systems will reuse or recycle most of the materials of the product you are disposing in a sound way.
Preliminary Draft South Korea International Eye Safety Statement: LED This device has been tested in accordance with IEC60825-1 LED safety, and has been certified to be a Class 1 LED product. CB Scheme Certified to IEC60950-1 (2001) First Edition. Patents Please refer to the product packaging for patent information. Solids and Water Protection The Xenon 1900 has a rating of IP41, immunity of foreign particles and dripping water.
Preliminary Draft Product Agency Compliance - Xenon 1902 and CCB01-010BT Base USA FCC Part 15 Subpart C This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation.
Preliminary Draft C-UL Statement C-UL listed: CSA C22.2 No.60950-1-03 for I.T.E product safety. Europe The CE marking on the product indicates that this device is in conformity with all essential requirements of the 1999/5/EC R&TTE Directive. In addition, complies to 2006/95/EC Low Voltage Directive, when shipped with recommended power supply. For further information, contact: Honeywell Imaging & Mobility Europe BV International Inc.
Preliminary Draft If you need more information on the collection, reuse, and recycling systems, contact your local or regional waste administration. You may also contact your supplier for more information on the environmental performances of this product. Germany If your product is marked with the GS symbol, then the product has been issued a GS certificate showing compliance to IEC 60950-1. Australia/NZ C-Tick Statement Conforms to AS/NZS 3548 EMC requirements.
Preliminary Draft Eye Safety Statement LED This device has been tested in accordance with IEC60825-1: 1993+A1+A2 LED safety, and has been certified to be a Class 1 LED device. Radio Technology Class II CB Scheme Certified to CB Scheme IEC 60950-1. Solids and Water Protection The Xenon 1902 has a rating of IP41, immunity of foreign particles and dripping water. Patents Refer to product packaging for patent information.
Preliminary Draft Required Safety Labels Scanner Illumination output Item Number, Serial Number and Revision Information location Compliance Label location
Preliminary Draft CCB01-010BT Base Item Number, Serial Number and Revision Information location Compliance Label location
Preliminary Draft Table of Contents Chapter 1 - Getting Started About This Manual ...................................................... 1-1 Unpacking Your Device............................................... 1-1 Connecting the Device ................................................ 1-2 Connecting with USB ............................................ 1-2 Connecting with Keyboard Wedge ........................ 1-3 Connecting with RS232 Serial Port ....................... 1-5 Connecting with RS485..........
Preliminary Draft Wincor Nixdorf Beetle™ Terminal Default Settings ................................................ 2-9 Keyboard Country Layout ..........................................2-10 Keyboard Style ..........................................................2-17 Keyboard Conversion ................................................2-18 Control Character Output...........................................2-19 Keyboard Modifiers....................................................2-19 RS232 Baud Rate........
Preliminary Draft Proper Disposal of the Battery .............................. 3-5 Beeper and LED Sequences and Meaning ................. 3-5 Scanner LED Sequences and Meaning ................ 3-6 Base LED Sequences and Meaning ..................... 3-6 Base Power Communication Indicator .................. 3-7 Reset Scanner ............................................................ 3-7 Scanning while in Base Cradle ................................... 3-7 Paging ...........................................
Preliminary Draft Resetting the Factory Defaults: All Application Work Groups....................................3-23 Resetting the Custom Defaults: All Application Work Groups....................................3-24 Using the Scanner with Bluetooth Devices................3-24 PCs/Laptops ........................................................ 3-24 PDAs/Mobility Systems Devices .......................... 3-25 Changing the Scanner’s Bluetooth PIN Code......
Preliminary Draft Presentation Sensitivity ....................................... 4-10 Streaming Presentation™ Mode ............................... 4-10 Mobile Phone Read Mode......................................... 4-11 Image Snap and Ship................................................ 4-11 Hands Free Time-Out ............................................... 4-11 Reread Delay ............................................................ 4-12 User-Specified Reread Delay....................................
Preliminary Draft Prefix Selections ..........................................................5-3 Suffix Selections ..........................................................5-4 Function Code Transmit ..............................................5-4 Intercharacter, Interfunction, and Intermessage Delays..........................................5-4 Intercharacter Delay .............................................. 5-5 User Specified Intercharacter Delay ...................... 5-5 Interfunction Delay.......
Preliminary Draft Code 93 Code Page............................................ 7-14 Straight 2 of 5 Industrial (three-bar start/stop) .......... 7-15 Straight 2 of 5 IATA (two-bar start/stop).................... 7-16 Matrix 2 of 5 .............................................................. 7-17 Code 11..................................................................... 7-18 Code 128................................................................... 7-19 ISBT 128 Concatenation ..........................
Preliminary Draft Single 2D Postal Codes: ...................................... 7-51 Combination 2D Postal Codes:............................ 7-52 Postal Codes - Linear ................................................7-54 China Post (Hong Kong 2 of 5) ............................ 7-54 Korea Post ........................................................... 7-56 Chapter 8 - Imaging Commands Single-Use Basis .........................................................8-1 Command Syntax ..........................
Preliminary Draft Chapter 11 - Serial Programming Commands Conventions .............................................................. 11-1 Menu Command Syntax............................................ 11-1 Query Commands ..................................................... 11-2 Responses .......................................................... 11-3 Trigger Commands ................................................... 11-4 Resetting the Standard Product Defaults .................. 11-4 Menu Commands ....
Preliminary Draft Chapter 14 - Customer Support Appendix A - Reference Charts Symbology Chart ........................................................ A-1 ASCII Conversion Chart (Code Page 1252) ............... A-4 Code Page Mapping of Printed Barcodes ..................
1 Preliminary Draft Getting Started About This Manual This User’s Guide provides installation and programming instructions for the Xenon™ 1900 and 1902 area-imaging scanners. Product specifications, dimensions, warranty, and customer support information are also included. Honeywell bar code scanners are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide.
Preliminary Draft Connecting the Device Connecting with USB A scanner or a cordless base can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the device first, then to the computer.
Preliminary Draft 2. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. 3. The scanner beeps. 4. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this manual. The unit defaults to a USB PC Keyboard. Refer to page 2-4 for other USB terminal settings. For additional USB programming and technical information, refer to “USB Application Note,” available at www.
Preliminary Draft Cordless Base Keyboard Wedge Connection: 3. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. 4. Turn the terminal/computer power back on. The scanner beeps. 5. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this manual. The scanner beeps once.
Preliminary Draft Connecting with RS232 Serial Port 1. Turn off power to the terminal/computer. 2. Connect the appropriate interface cable to the scanner. Note: For the scanner or cordless base to work properly, you must have the correct cable for your type of terminal/computer.
Preliminary Draft 3. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. 4. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. 5. Once the scanner or cordless base has been fully connected, power up the computer. This interface programs 115,200 baud, 8 data bits, no parity, and 1 stop bit.
Preliminary Draft Cordless Base RS485 Connection: 2. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. 3. Turn the terminal/computer power back on. The scanner beeps. 4. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this manual. The scanner beeps once. For further RS485 settings, refer to RS485, page 2-2..
Preliminary Draft Reading Techniques The scanner has a view finder that projects a bright red aiming beam that corresponds to the scanner’s horizontal field of view. The aiming beam should be centered over the bar code, but it can be positioned in any direction for a good read. Linear bar code 2D Matrix symbol The aiming beam is smaller when the scanner is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit.
Preliminary Draft Resetting the Factory Defaults If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want the factory default settings restored, first scan the Restore Factory Defaults bar code, then scan Save Defaults. This resets the scanner to the factory defaults. Restore Factory Defaults Save Defaults Note: If using a cordless system, scanning the Save Defaults bar code also causes both the scanner and the base to perform a reset and become unlinked.
Preliminary Draft When you have entered all the commands you want to save for your custom defaults, scan the Save Custom Defaults bar code. Set Custom Defaults Save Custom Defaults Note: If using a cordless system, scanning the Save Defaults bar code also causes both the scanner and the base to perform a reset and become unlinked. The scanner must be placed in its base to re-establish the link before any setup codes are entered.
2 Preliminary Draft Programming the Interface Introduction This chapter describes how to program your system for the desired interface. Programming the Interface - Plug and Play Plug and Play bar codes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.
Preliminary Draft RS232 Serial Port The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal. The following RS232 Interface bar code also programs a carriage return (CR) and a line feed (LF) suffix, baud rate, and data format as indicated below. It also changes the trigger mode to manual.
Preliminary Draft Each bar code above also programs the following suffixes for each symbology: Symbology Suffix Symbology Suffix EAN 8 EAN 13 UPC A UPC E 0C 16 0D 0A Code 39 Interleaved 2 of 5 Code 128 * Code 128 ** 00 00 00 00 0A 0D 0A 18 0B 0B 0B 0B * Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B HHBCR-1, and IBM 4683 Port 17 Interfaces **Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Interface RS485 Packet Mode The following selection allows you to bre
Preliminary Draft USB IBM SurePos Scan one of the following “Plug and Play” codes to program the scanner for an IBM SurePos (USB handheld scanner) or IBM SurePos (USB tabletop scanner) interface. Note: After scanning one of these codes, you must power cycle the cash register.
Preliminary Draft USB HID Scan the following code to program the scanner for USB HID bar code scanners. USB HID Bar Code Scanner USB Serial Scan the following code to program the scanner to emulate a regular RS232-based COM Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Honeywell website (www.honeywellaidc.com). The driver will use the next available COM Port number.
Preliminary Draft ACK/NAK Mode ACK/NAK Mode On * ACK/NAK Mode Off Verifone® Ruby Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Verifone Ruby terminal. This bar code sets the baud rate to 1200 bps and the data format to 8 data bits, no parity bit, 1 stop bit.
Preliminary Draft Gilbarco® Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Gilbarco terminal. This bar code sets the baud rate to 2400 bps and the data format to 7 data bits, even parity, 2 stop bits.
Preliminary Draft NCR Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for an NCR bioptic scanner auxiliary port configuration.
Preliminary Draft Wincor Nixdorf Beetle™ Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf Beetle terminal.
Preliminary Draft Keyboard Country Layout Scan the appropriate country code below to program the keyboard layout for your country or language. As a general rule, the following characters are supported, but need special care for countries other than the United States: @ | $ # { } [ ] = / ‘ \ < > ~ * United States United States (Dvorak) United States (Dvorak left) United States (Dvorak right) United States (International) Albania Azeri (Cyrillic) Azeri (Latin) Belarus Belgium Bosnia Brazil 2 - 10
Preliminary Draft Keyboard Country (continued) Brazil (MS) Bulgaria (Cyrillic) Bulgaria (Latin) Canada (French legacy) Canada (French) Canada (Multilingual) Croatia Czech Czech (Programmers) Czech (QWERTY) Czech (QWERTZ) Denmark Dutch (Netherlands) 2 - 11
Preliminary Draft Keyboard Country (continued) Estonia Faeroese Finland France Gaelic Germany Greek Greek (220 Latin) Greek (220) Greek (319 Latin) Greek (319) Greek (Latin) Greek (MS) 2 - 12
Preliminary Draft Keyboard Country (continued) Greek (Polytonic) Hebrew Hungarian (101 key) Hungary Iceland Irish Italian (142) Italy Japan ASCII Kazakh Kyrgyz (Cyrillic) Latin America Latvia 2 - 13
Preliminary Draft Keyboard Country (continued) Latvia (QWERTY) Lithuania Lithuania (IBM) Macedonia Malta Mongolian (Cyrillic) Norway Poland Polish (214) Polish (Programmers) Portugal Romania Russia 2 - 14
Preliminary Draft Keyboard Country (continued) Russian (MS) Russian (Typewriter) SCS Serbia (Cyrillic) Serbia (Latin) Slovakia Slovakia (QWERTY) Slovakia (QWERTZ) Slovenia Spain Spanish variation Sweden Switzerland (French) 2 - 15
Preliminary Draft Keyboard Country (continued) Switzerland (German) Tatar Turkey F Turkey Q Ukrainian United Kingdom United Stated (Dvorak right) United States (Dvorak left) United States (Dvorak) United States (International) Uzbek (Cyrillic) Refer to the Honeywell website (www.honeywell.com/aidc) for complete keyboard country support information and applicable interfaces.
Preliminary Draft appropriate country from the inside back cover, then the Save bar code. Program Keyboard Country Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. If you have used Keyboard Conversion settings, they will override any of the following Keyboard Style settings. Default = Regular. Regular is used when you normally have the Caps Lock key off. * Regular Caps Lock is used when you normally have the Caps Lock key on.
Preliminary Draft Autocaps via NumLock bar code should be scanned in countries (e.g., Germany, France) where the Caps Lock key cannot be used to toggle Caps Lock. The NumLock option works similarly to the regular Autocaps, but uses the NumLock key to retrieve the current state of the Caps Lock. Autocaps via NumLock Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent).
Preliminary Draft Control Character Output This selection sends a text string instead of a control character. For example, when the control character for a carriage return is expected, the output would display [CR] instead of the ASCII code of 0D. Refer to ASCII Conversion Chart (Code Page 1252) on page A-4. Only codes 00 through 1F are converted (the first column of the chart). Note: Control + ASCII Mode overrides this mode. Default = Off.
Preliminary Draft Default = Control + ASCII Mode Off. Windows Mode Control + ASCII Mode On * Control + ASCII Mode Off DOS Mode Control + ASCII Mode On Windows Mode Prefix/Suffix Off Turbo Mode: The scanner sends characters to a terminal faster. If the terminal drops characters, do not use Turbo Mode. Default = Off Turbo Mode On * Turbo Mode Off Numeric Keypad Mode: Sends numeric characters as if entered from a numeric keypad.
Preliminary Draft Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters.
Preliminary Draft RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate. The host terminal must be set for the same baud rate as the scanner. Default = 9600.
Preliminary Draft RS232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications that require use of the full ASCII set, select 8 data bits per character. Default = 8. Stop Bits sets the stop bits at 1 or 2. Default = 1. Parity provides a means of checking character bit patterns for validity. Default = None.
Preliminary Draft RS232 Receiver Time-Out The unit stays awake to receive data until the RS232 Receiver Time-Out expires. A manual or serial trigger resets the time-out. When an RS232 receiver is sleeping, a character may be sent to wake up the receiver and reset the time-out. A transaction on the CTS line will also wake up the receiver. The receiver takes 300 milliseconds to completely come up.
Preliminary Draft RS232 Timeout When using Flow Control with Timeout, you must program the length of the delay you want to wait for CTS from the host. Set the length (in milliseconds) for a timeout by scanning the bar code below, then setting the timeout (from 1-5100 milliseconds) by scanning digits from the inside back cover, then scanning Save.
Preliminary Draft the scanner waits for ACK/NAK again. Turn on the ACK/NAK protocol by scanning the ACK/NAK On bar code below. To turn off the protocol, scan ACK/NAK Off. Default = ACK/NAK Off. ACK/NAK On * ACK/NAK Off Scanner to Bioptic Communication The following settings are used to set up communication between Honeywell scanners and bioptic scanners. Note: The scanner’s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate with a bioptic scanner.
Preliminary Draft Scanner-Bioptic ACK/NAK Mode Bioptic ACK/Nak On must be scanned so the scanner will wait for an ACK or NAK from a bioptic scanner after each packet is sent. The ScannerBioptic ACK/NAK Timeout (below) controls how long the scanner will wait for a response. Default = Bioptic ACK/NAK Off. * Bioptic ACK/NAK Off Bioptic ACK/NAK On Scanner-Bioptic ACK/NAK Timeout This allows you to set the length (in milliseconds) for a timeout for a bioptic scanner’s ACK/NAK response.
Preliminary Draft 2 - 28
3 Preliminary Draft Cordless System Operation Note: This chapter applies only to cordless scanning systems. It does not apply to corded scanners. How the Cordless Base Works The cordless base provides the link between the cordless scanner and the host system. The base contains an interface assembly and an RF communication module. The RF communication module performs the data exchange between the cordless scanner and the interface assembly.
Preliminary Draft Communication Between the Cordless System and the Host The cordless scanner provides immediate feedback in the form of a “good read” indication (a green LED on the scanner and an audible beep) after a bar code is scanned correctly and the base has acknowledged receiving the data. This is possible since the cordless system provides two-way communication between the scanner and the base. When data is scanned, the data is sent to the host system via the base unit.
Preliminary Draft Linking Process Once a scanner is placed into the base, the scanner’s battery charge status is checked, and software automatically detects the scanner and links it to the base depending on the selected link mode. Scanner Is Out of Range The cordless scanner is in communication with its base, even when it is not transmitting bar code data. Whenever the scanner can’t communicate with the base for a few seconds, it is out of range.
Preliminary Draft Power is supplied to the cordless scanner by a rechargeable battery that is integrated in the scanner handle. Batteries are shipped approximately 30% to 60% charged and should be fully charged for maximum charge capacity. Charging Information The battery is designed to charge while the scanner is positioned in the cordless base unit. Refer to Base LED Sequences and Meaning, page 36, for an interpretation of the Charge Status indicators.
Preliminary Draft Proper Disposal of the Battery When the battery has reached the end of its useful life, the battery should be disposed of by a qualified recycler or hazardous materials handler. Do not incinerate the battery or dispose of the battery with general waste materials. You may send the scanner’s battery to us. (postage paid).
Preliminary Draft Scanner LED Sequences and Meaning LED Indication Beeper Indication Cause Normal Operation Red Flash Green Flash None 1 beep Battery low Successful communication or linking Failed communication Red, blinking Menu Operation Green Flash Red, blinking Razz or error tone 2 beeps Razz or error tone Successful menu change Unsuccessful menu change Base LED Sequences and Meaning The base contains a red LED that indicates the status of the unit and verifies its communication with the host s
Preliminary Draft Base Power Communication Indicator To display the power indicator on the base, scan the Base Power Communication Indicator On bar code. To turn off the power indicator, scan the Off bar code. Default = On. * Base Power Communication Indicator On Base Power Communication Indicator Off Reset Scanner Scanning this bar code causes the scanner to re-link with the base.
Preliminary Draft Paging Paging Mode By default, the paging button on the base pages the scanners associated with that base. If you want the paging button on your base to be disabled, scan the Paging Mode Off bar code, below. When Paging Mode is off, the base will no longer page scanners when the button is pressed. The red LED on the base will remain lit to indicate that Paging Mode is off. (This light will go out when the button is pressed, then back on when it’s released.) Default = Paging Mode On.
Preliminary Draft Error Indicators Beeper Pitch - Base Error The base can be configured to beep at a particular pitch when an error occurs, such as transmission problems to a host system. The beeper pitch codes modify the pitch (frequency) of the error tone the base emits when there is an error. Default = Low. * Razz (250 Hz) Medium (3250 Hz) High (4200 Hz) Number of Beeps - Base Error The number of beeps and LED flashes emitted by the base for an error condition can be programmed from 1 - 9.
Preliminary Draft Scanner Address Scan the bar code below to determine the address of the scanner you are using. Scanner Address Base Address Scan the bar code below to determine the address of the base you are using. Base Address Single Scanner Modes The Xenon is capable of working in single scanner mode, multiple scanner mode, or with Bluetooth devices other than the CCB01-010BT charge base. Charge Only Mode There may be times when you want to charge your scanner, but not link to the base.
Preliminary Draft Linked Modes Locked Link Mode and Open Link Mode are the link modes that accommodate different applications. Scan the appropriate bar codes included in the Open Link and Locked Link Mode explanations that follow to switch from one mode to another. Default = Open Link Mode. Locked Link Mode - Single Scanner If you link a scanner to a base using the Locked Link Mode, other scanners are blocked from being linked if they are inadvertently placed into the base.
Preliminary Draft Override Locked Scanner If you need to replace a broken or lost scanner that is linked to a base, scan the Override Locked Scanner bar code below with a new scanner and place that scanner in the base. The locked link will be overridden; the broken or lost scanner’s link with the base will be removed, and the new scanner will be linked. Override Locked Scanner (Single Scanner) Out-of-Range Alarm If your scanner is out range of the base, an alarm sounds from both your base and scanner.
Preliminary Draft Setting Sound 2 4 short beeps, medium pitch 3 4 short beeps, high pitch 4 single chirps, medium pitch 5 2 chirps, then 1 chirp, medium pitch 6 single chirps, high pitch 7 2 chirps, then 1 chirp, high pitch Base Alarm Type Scanner Alarm Type Flexible Power Management If you are experiencing network performance issues, and suspect the scanner is interfering with other devices, you can turn down the power output of the scanner.
Preliminary Draft For the new power setting to take effect, the scanner and base must be reset. See Reset Scanner and Base (page 3-14). * Full Power Medium Power Medium Low Power Low Power Reset Scanner and Base Once the power level is set, you must scan the Reset Base bar code and wait for the scanner to unlink and relink to the base. Once that is done, scan the Reset Scanner bar code and wait for the base to unlink and relink to the scanner. Reset Scanner Reset : * : R E SBase E T _ .
Preliminary Draft Inventory Batch Mode stores bar code data, whether or not you are in range of the base. To transmit the stored data to the base, either place the scanner in the base, or scan Transmit Inventory Records (page 3-19). When the scanner’s buffer space is full, any bar codes scanned generate an error tone. In order to scan bar codes again, the data must be transmitted to the base. Default = Batch Mode Off.
Preliminary Draft RAM Storage: The scanner will not power down while it contains data that has not been transmitted to the base, even if it reaches a power down timeout. However, if the scanner runs out of battery power, it will power down and the data will be lost. Default = Flash Storage. * Flash Storage RAM Storage Batch Mode Quantity When in Batch Mode, you may wish to transmit the number of multiple bar codes scanned, rather than a single bar code multiple times.
Preliminary Draft 2. 3. 4. 5. Scan the quantity 1 bar code. Scan the quantity 5 bar code. Scan the quantity 0 bar code. Scan the quantity 0 bar code. Example: Change a quantity of 103 to 10. To correct an incorrect quantity, scan the quantity 0 bar code to replace the incorrect digits, then scan the correct quantity bar codes. 1. 2. 3. 4. Scan the quantity 0 bar code to change the quantity to 1030. Scan the quantity 0 bar code to change the quantity to 0300.
Preliminary Draft Quantity Codes (continued) 8 9 Batch Mode Output Order When data is transmitted to the base, select whether you want that data sent as FIFO (first-in first-out), or LIFO (last-in last-out). Batch Mode FIFO Batch Mode LIFO Delete Last Code If you are accumulating data in Batch Mode and want to delete the last bar code scanned, scan Delete Last Code. Delete Last Code Clear All Codes If you want to clear the scanner’s buffer of all data accumulated in Batch Mode, scan Clear All Codes.
Preliminary Draft Transmit Records to Host If you are operating in Inventory Batch Mode (see Inventory Batch Mode on page 3-15), you must scan the following bar code to transmit all the stored data to the host system. Transmit Inventory Records Batch Mode Transmit Delay Sometimes when accumulated scans are sent to the host system, the transmission of those scans is too fast for the application to process. To program a transmit delay between accumulated scans, scan one of the following delays.
Preliminary Draft To put the scanner in multiple scanner mode, scan the bar code below. Once you scan this bar code, the scanner is unlinked from the base and must be placed into the base to re-link. Multiple Scanner Operation Scanner Name You may assign a name to each scanner you are using. When you have multiple scanners linked to one base, you may want to name each scanner so you will be able to control the scanner receiving imaging commands sent from the base. The default name for a Xenon is “Xenon.
Preliminary Draft To rename scanners with sequential, numeric names, scan the bar codes below. Scan the Reset code after each name change and wait for the scanner to re-link to the base before scanning another bar code to rename the next scanner. 0001 0002 0003 0004 0005 0006 0007 Reset Alternatively, you may change the name with a bar code command if you cannot send serial commands to the base. One way to do this is to scan the bar code below and scan a number for the scanner name.
Preliminary Draft If you want to assign an alphabetic name to the scanner, create a Code 128 bar code containing “~BT_NAMname.” followed by a FNC3 character (hexidecimal 83), where name is the new scanner name. Scan the Reset bar code (page 321 or on the Programming Chart inside the back cover of this manual). Application Work Groups Your cordless system can have up to 7 scanners linked to one base. You can also have up to 7 work groups.
Preliminary Draft Application Work Group Selection This programming selection allows you to assign a scanner to a work group by scanning the bar code below. You may then program the settings (e.g., beeper volume, prefix/suffix, data formatter) that your application requires. Default = Group 0. * Group 0 Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Resetting the Factory Defaults: All Application Work Groups The following bar code defaults all of the work groups to the factory default settings.
Preliminary Draft To see what the factory default settings are, refer to the table of Menu Commands, beginning on page 11-5. The standard product default settings for each of the commands are indicated by an asterisk (*). Note: Scanning this bar code also causes both the scanner and the base to perform a reset and become unlinked. The scanner must be placed in its base to re-establish the link. Refer to Single Scanner Modes, page 3-10 for additional information.
Preliminary Draft with your scanner, the scanner will not reconnect to the Bluetooth device when it is back in range. If you want to re-link to the charge base, refer to Override Locked Scanner, page 3-12. Note: The multiple work groups option is not available when you are using the scanner with Bluetooth devices other than the charge base. Non-Base BT Connection PDAs/Mobility Systems Devices You may also use the scanner with a PDA or a Honeywell Mobility Systems device.
Preliminary Draft Auto Reconnect Mode Auto Reconnect controls whether or not the scanner automatically begins the re-link process when a loss of connection is detected. When the Auto Reconnect On bar code is scanned, the scanner begins the re-link process immediately, without user intervention. Default = Auto Reconnect On. * Auto Reconnect On Auto Reconnect Off Note: If you are connecting to a Bluetooth Interface Module, set Auto Reconnect to Off.
Preliminary Draft Event Auto Reconnect On Auto Reconnect Off Scanner reset due to firmware upgrade Re-link occurs automatically. Scanner reset due to battery change Re-link occurs automatically. Scanner placed in different base unit Re-link to new base occurs automatically. Maximum Link Attempts The Maximum Link Attempts setting controls the number of times the scanner tries to form a connection with a base unit or PC.
Preliminary Draft Scan the Relink Time-Out bar code, then scan the number of seconds for the setting (from 1-100) from the inside back cover. Scan Save to save the setting. Default = 3 seconds. Relink Time-Out Bluetooth/ISM Network Activity Examples Default values When the scanner goes out of range, the scanner repeatedly attempts to connect to base unit. Each attempt consists of approximately 5 seconds of active time followed by 3 seconds of idle time.
Preliminary Draft Host Command Acknowledgment Some applications require that the host terminal (or server) approve or reject incoming bar code data and notify the operator of these actions. These applications require that the host maintain control over the response indicators emitted from the scanner. Turning on Host ACK configures the scanner to respond to commands from the host system. Note: System performance degrades when using Host ACK at rates lower than 9600 baud.
Preliminary Draft Host Acknowledgment On/Off Host ACK On * Host ACK Off Cordless Base Host Escape Commands Command Action a Double beeps to indicate a successful menu change was made. b Razz or error tone to indicate a menu change was unsuccessful. 1 The green LED illuminates for 135 milliseconds followed by a pause. 2 The green LED illuminates for 2 seconds followed by a pause. 3 The green LED illuminates for 5 seconds followed by a pause.
4 Preliminary Draft Input/Output Settings Power Up Beeper The scanner can be programmed to beep when it’s powered up. If you are using a cordless system, the base can also be programmed to beep when it is powered up. Scan the Off bar code(s) if you don’t want a power up beep. Default = Power Up Beeper On - Scanner.
Preliminary Draft Trigger Click To hear an audible click every time the scanner trigger is pressed, scan the Trigger Click On bar code below. Scan the Trigger Click Off code if you don’t wish to hear the click. (This feature has no effect on serial or automatic triggering.) Default = Trigger Click Off. *Trigger Click Off Trigger Click On Good Read and Error Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read.
Preliminary Draft Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read. Default = High. Low Medium * High Off Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the scanner emits on a good read. Default = Medium.
Preliminary Draft Beeper Pitch – Error The beeper pitch codes modify the pitch (frequency) of the sound the scanner emits when there is a bad read or error. Default = Low. * Razz (250 Hz) Medium (3250 Hz) High (4200 Hz) Beeper Duration – Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read. Default = Normal. * Normal Beep Short Beep LED – Good Read The LED indicator can be programmed On or Off in response to a good read. Default = On.
Preliminary Draft Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have five beeps, there will be five beeps and five LED flashes in response to a good read. The beeps and LED flashes are in sync with one another.
Preliminary Draft Good Read Delay This sets the minimum amount of time before the scanner can read another bar code. Default = 0 ms (No Delay). * No Delay Short Delay (500 ms) Medium Delay (1,000 ms) Long Delay (1,500 ms) User-Specified Good Read Delay If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save.
Preliminary Draft ble scan speed but slightly less range than Normal mode. Enhanced mode is best used when you require a very fast scan speed and don’t require a long working range. * Manual Trigger - Normal Manual Trigger - Enhanced Serial Trigger You can activate the scanner either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 11-4). When in serial mode, the scanner scans until a bar code has been read or until the deactivate command is sent.
Preliminary Draft If there are no trigger pulls during the timer interval, the scanner goes into power down mode. Whenever the trigger is enabled, the timer is reset. If the scanner is placed in the charge base cradle and the battery is in the process of being charged, the scanner will not go into power down mode. Default = 3600 seconds. 0 seconds 200 seconds 400 seconds 900 seconds * 3600 seconds 7200 seconds Note: When the scanner is in power down mode, pull the trigger to power the unit back up.
Preliminary Draft scanner is programmed for Presentation Mode (page 4-9), it would be in presentation mode whenever it is in the stand, and in manual trigger mode whenever it is removed from the stand. Default = Sensor On. * Sensor On Sensor Off Presentation Mode Presentation Mode uses ambient light to detect bar codes. The LEDs remain off until a bar code is presented to the scanner, then the LEDs turn on automatically to read the code.
Preliminary Draft Presentation Sensitivity Presentation Sensitivity is a numeric range that increases or decreases the scanner's reaction time to bar code presentation. To set the sensitivity, scan the Sensitivity bar code, then scan the degree of sensitivity (from 020) from the inside back cover, and Save. 0 is the most sensitive setting, and 20 is the least sensitive. Default = 1.
Preliminary Draft Mobile Phone Read Mode When this mode is selected, your scanner is optimized to read bar codes from mobile phone or other LED displays. However, the speed of scanning printed bar codes may be slightly lower when this mode is enabled. You can enable Mobile Phone Reading for either a hand held device, or for a hands-free (presentation) application.
Preliminary Draft Scan the Hands Free Time-Out bar code, then scan the time-out duration (from 0-300,000 milliseconds) from the inside back cover, and Save. Default = 5,000 ms. Hands Free Time-Out Reread Delay This sets the time period before the scanner can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads.
Preliminary Draft Illumination Lights If you want the illumination lights on while reading a bar code, scan the Lights On bar code, below. However, if you want to turn just the lights off, scan the Lights Off bar code. Default = Lights On. Note: This setting does not affect the aimer light. The aiming light can be set using Aimer Mode (page 4-14). * Lights On Lights Off Aimer Delay The aimer delay allows a delay time for the operator to aim the scanner before the picture is taken.
Preliminary Draft Scanner Time-Out Note: Scanner Time-Out applies only to corded scanners. It does not apply to cordless systems. Scanner Time-Out powers down the scanner after the unit has been idle for the specified time. To prevent the scanner from powering down, set this time-out to 0. Sca Scanner Time-Out, then set the time-out by scanning digits (from 0 999,999 ms) from the inside back cover, then scanning Save. Default = 60,000 ms.
Preliminary Draft In the example below, the gray area is the full scanner field of view and the white area is the centering window. Bar Code 1 will not be read, while Bar Code 2 will be. Bar Code 1 Bar Code 2 The default centering window is a 169x128 pixel area in the center of the scanner’s field of view. The following diagram illustrates the default top, bottom, left, and right pixel positions, measured from the top and the left side of the scanner’s field of view, which is 844 by 640 pixels.
Preliminary Draft Scan Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual. Scan Save. Default Centering = 40% for Top and Left, 60% for Bottom and Right.
Preliminary Draft Scan a bar code below to enable or disable Preferred Symbology. Preferred Symbology Off. Default = Preferred Symbology On * Preferred Symbology Off High Priority Symbology To specify the high priority symbology, scan the High Priority Symbology bar code below. On the Symbology Chart on page A-1, find the symbology you want to set as high priority. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover).
Preliminary Draft bar code has been encountered. Scan the bar code below, then set the delay (from 1-3,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. Default = 500 ms. Preferred Symbology Time-out Preferred Symbology Default Scan the bar code below to set all Preferred Symbology entries to their default values.
Preliminary Draft To Add an Output Sequence 1. Scan the Enter Sequence symbol (see Require Output Sequence, page 4-22). 2. Code I.D. On the Symbology Chart on page A-1, find the symbology to which you want to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover). 3. Length Specify what length (up to 9999 characters) of data output will be acceptable for this symbology.
Preliminary Draft Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below. Note: Code 93 must be enabled to use this example.
Preliminary Draft SEQBLKsequence editor start command 62 code identifier for Code 39 0012 A - Code 39 sample length (11) plus CR suffix (1) = 12 41 start character match for Code 39, 41h = “A” FF termination string for first code 6A code identifier for Code 128 0013 B - Code 128 sample length (12) plus CR suffix (1) = 13 42 start character match for Code 128, 42h = “B” FF termination string for second code 69 code identifier for Code 93 0012 C - Code 93 sample length (11) plus CR suffix (
Preliminary Draft Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device. When it’s On/Not Required, the scanner will attempt to get the output data to conform to an edited sequence but, if it cannot, the scanner transmits all output data to the host device as is. When the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Default = Off.
Preliminary Draft No Read With No Read turned On, the scanner notifies you if a code cannot be read. If using an EZConfig Tool Scan Data Window (see page 10-3), an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear. Default = Off. On * Off If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message (see Data Formatting beginning on page 6-1). The hex code for the No Read symbol is 9C.
Preliminary Draft 4 - 24
5 Preliminary Draft Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data.
Preliminary Draft symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”. Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page 1252) on page A-4, for the prefix or suffix you wish to enter. Step 5. Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual. Step 6.
Preliminary Draft Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Symbology Chart, beginning on page A-1) for the symbology from which you want to clear the prefix or suffix. Step 3. Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Your change is automatically saved.
Preliminary Draft Suffix Selections Add Suffix Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page 9-3. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable.
Preliminary Draft Intercharacter Delay An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.
Preliminary Draft Interfunction Delay An interfunction delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each segment of the message string. Scan the Interfunction Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.
Preliminary Draft 6 Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output. Default Data Format setting = None.
Preliminary Draft you are programming. (See Primary/Alternate Data Formats on page 6-10 for further information.) Step 3. Terminal Type Refer to Terminal ID Table (page 6-4) and locate the Terminal ID number for your PC. Scan three numeric bar codes on the inside back cover to program the scanner for your terminal ID (you must enter 3 digits). For example, scan 0 0 3 for an AT wedge. Note: The wildcard for all terminal types is 099. Step 4. Code I.D.
Preliminary Draft Other Programming Selections Clear One Data Format This deletes one data format for one symbology. If you are clearing the primary format, scan 0 from the Programming Chart inside the back cover of this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending on the format you are clearing. Scan the Terminal Type and Code I.D. (see Symbology Chart on page A-1), and the bar code data length for the specific data format that you want to delete.
Preliminary Draft Terminal ID Table Terminal Model(s) IBM PC/AT and compatibles USB SurePOS Handheld Scanner USB SurePOS Tabletop Scanner True TTL RS232 RS485 USB Serial PC Keyboard Mac Keyboard Japanese Keyboard (PC) HID POS Terminal ID 003 128 129 000 000 051 130 124 125 134 131 Data Format Editor Commands Send Commands Send all characters F1 Include in the output message all of the characters from the input message, starting from current cursor position, followed by an insert character.
Preliminary Draft ASCII code, and xx stands for the insert character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4 for decimal, hex and character codes. Send all but the last characters E9 Include in the output message all but the last “nn” characters, starting from the current cursor position. The cursor is moved forward to one position past the last input message character included.
Preliminary Draft Move the cursor to the end EA Move the cursor to the last character in the input message. Syntax = EA. Search Commands Search forward for a character F8 Search the input message forward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx” character. Syntax = F8xx where xx stands for the search character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4 for decimal, hex and character codes.
Preliminary Draft Search backward for a non-matching character E7 Search the input message backward for the first non-“xx” character from the current cursor position, leaving the cursor pointing to the non“xx” character. Syntax = E7xx where xx stands for the search character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4 for decimal, hex and character codes.
Preliminary Draft example, B2000454657374 will compare the string at the current cursor position with the 4 character string “Test.” Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4 for decimal, hex and character codes. Check for a number EC Check to make sure there is an ASCII number at the current cursor position. The format is aborted if the character is not numeric.
Preliminary Draft Data Format Required, Drop Prefix/Suffix Scanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and suffixes are not transmitted. Any data that does not match your data format requirements generates an error tone. If you wish to process this type of bar code without generating an error tone, see Data Format Non-Match Error Tone. Choose one of the following options.
Preliminary Draft Primary/Alternate Data Formats You can save up to four data formats, and switch between these formats. Your primary data format is saved under 0. Your other three formats are saved under 1, 2, and 3. To set your device to use one of these formats, scan one of the bar codes below. Primary Data Format Data Format 1 Data Format 2 Data Format 3 Single Scan Data Format Change You can also switch between data formats for a single scan.
Preliminary Draft For example, you may have set your device to the data format you saved as Data Format 3. You can switch to Data Format 1 for a single trigger pull by scanning the Single Scan-Data Format 1 bar code below. The next bar code that is scanned uses Data Format 1, then reverts back to Data Format 3.
Preliminary Draft 6 - 12
7 Preliminary Draft Symbologies This programming section contains the following menu selections. Refer to Chapter 11 for settings and defaults.
Preliminary Draft All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular symbology. All Symbologies On All Symbologies Off Note: When All Symbologies On is scanned, 2D Postal Codes are not enabled. 2D Postal Codes must be enabled separately.
Preliminary Draft Codabar Codabar On/Off * On Off Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Codabar Check Character Codabar check characters are created using different “modulos.” You can program the scanner to read only Codabar bar codes with Modulo 16 check characters.
Preliminary Draft When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. * No Check Character Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit Codabar Concatenation Codabar supports symbol concatenation.
Preliminary Draft Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60.
Preliminary Draft Code 39 < Default All Code 39 Settings > Code 39 On/Off * On Off Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character.
Preliminary Draft When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Character. * No Check Character Validate, but Don’t Transmit Validate and Transmit Code 39 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-48.
Preliminary Draft which the bar codes are read, deleting the first space from each. The scanner transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space. Default = Off. On * Off Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known as PARAF. Note: Trioptic Code (page 7-38) must be turned off while scanning Code 32 Pharmaceutical codes.
Preliminary Draft Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off.
Preliminary Draft and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Code 39 Code Page Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 On/Off * On Off Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit.
Preliminary Draft When Check Digit is set to Validate and Transmit, the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. * No Check Digit Validate, but Don’t Transmit Validate and Transmit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80.
Preliminary Draft NEC 2 of 5 < Default All NEC 2 of 5 Settings > NEC 2 of 5 On/Off * On Off Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
Preliminary Draft NEC 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80.
Preliminary Draft Code 93 < Default All Code 93 Settings > Code 93 On/Off * On Off Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 93 Code Page Code pages define the mapping of character codes to characters.
Preliminary Draft and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Code 93 Code Page Straight 2 of 5 Industrial (three-bar start/stop) Straight 2 of 5 Industrial On/Off On * Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length.
Preliminary Draft Straight 2 of 5 IATA (two-bar start/stop) Straight 2 of 5 IATA On/Off On * Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Preliminary Draft Matrix 2 of 5 Matrix 2 of 5 On/Off On * Off Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
Preliminary Draft Code 11 Code 11 On/Off On * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits.
Preliminary Draft Code 11 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
Preliminary Draft that supports concatenation of neighboring symbols, and 4) the standard layout for bar codes on a blood product label. Use the bar codes below to turn concatenation on or off. Default =Off. On * Off Code 128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80.
Preliminary Draft GS1-128 GS1-128 On/Off * On Off GS1-128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80.
Preliminary Draft Telepen Telepen On/Off On * Off Telepen Output Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output.
Preliminary Draft Telepen Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. Minimum Message Length Maximum Message Length UPC-A UPC-A On/Off * On Off UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.
Preliminary Draft UPC-A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. * On Off UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data. Default = Off for both 2 Digit and 5 Digit Addenda.
Preliminary Draft UPC-A Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On. * On Off UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code. When left on the default setting (Off), the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes.
Preliminary Draft UPC-E0 UPC-E0 On/Off Most U.P.C. bar codes lead with the 0 number system. To read these codes, use the UPC-E0 On selection. If you need to read codes that lead with the 1 number system, use UPC-E1 (page 7-29). Default = On. * UPC-E0 On UPC-E0 Off UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off.
Preliminary Draft UPC-E0 Addenda Required When Required is scanned, the scanner will only read UPC-E bar codes that have addenda. Default = Not Required. Required * Not Required UPC-E0 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = On. * On Off UPC-E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not.
Preliminary Draft UPC-E0 Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. To prevent transmission, scan Off. Default = On. * On Off UPC-E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda.
Preliminary Draft UPC-E1 Most U.P.C. bar codes lead with the 0 number system. For these codes, use UPC-E0 (page 7-26). If you need to read codes that lead with the 1 number system, use the UPC-E1 On selection. Default = Off. UPC-E1 On * UPC-E1 Off EAN/JAN-13 EAN/JAN-13 On/Off * On Off EAN/JAN-13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
Preliminary Draft EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-13 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-13 bar codes that have addenda. Default = Not Required.
Preliminary Draft EAN/JAN-13 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = On. * On Off Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code (page 7-25). ISBN Translate When On is scanned, EAN-13 Bookland symbols are translated into their equivalent ISBN number format. Default = Off.
Preliminary Draft EAN/JAN-8 EAN/JAN-8 On/Off * On Off EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
Preliminary Draft EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 bar codes that have addenda. Default = Not Required.
Preliminary Draft MSI MSI On/Off On * Off MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned data.
Preliminary Draft When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes printed with the specified type check character(s), but will not transmit the check character(s) with the scanned data.
Preliminary Draft GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > GS1 DataBar Omnidirectional On/Off * On Off GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited On/Off * On Off 7 - 36
Preliminary Draft GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > GS1 DataBar Expanded On/Off * On Off GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74.
Preliminary Draft Trioptic Code Note: If you are going to scan Code 32 Pharmaceutical codes (page 7-8), Trioptic Code must be off. Trioptic Code is used for labeling magnetic storage media.
Preliminary Draft Codablock A Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600.
Preliminary Draft Codablock F Codablock F On/Off On * Off Codablock F Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048.
Preliminary Draft PDF417 < Default All PDF417 Settings > PDF417 On/Off * On Off PDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750.
Preliminary Draft MicroPDF417 < Default All MicroPDF417 Settings > MicroPDF417 On/Off On * Off MicroPDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366.
Preliminary Draft GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology. GS1 Composite symbologies allow for the co-existence of symbologies already in use. On * Off UPC/EAN Version Scan the UPC/EAN Version On bar code to decode GS1 Composite symbols that have a U.P.C. or EAN linear component. (This does not affect GS1 Composite symbols with a GS1-128 or GS1 linear component.
Preliminary Draft GS1 Emulation The scanner can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1-128, and GS1-128 DataBar and GS1 Composites. (Any application that accepts GS1 data can be simplified since it only needs to recognize one data carrier type.) If GS1-128 Emulation is scanned, all retail codes (U.P.C.
Preliminary Draft TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component. All bar code readers are capable of reading the Code 39 linear component. The MicroPDF417 component can only be decoded if TLC39 On is selected. The linear component may be decoded as Code 39 even if TLC39 is off. Default = Off.
Preliminary Draft QR Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-7089. Minimum Default = 1, Maximum Default = 7089.
Preliminary Draft Data Matrix < Default All Data Matrix Settings > Data Matrix On/Off * On Off Data Matrix Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116.
Preliminary Draft MaxiCode < Default All MaxiCode Settings > MaxiCode On/Off * On Off MaxiCode Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150.
Preliminary Draft Aztec Code < Default All Aztec Code Settings > Aztec Code On/Off * On Off Aztec Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832.
Preliminary Draft Chinese Sensible (Han Xin) Code < Default All Han Xin Settings > Han Xin Code On/Off On * Off Han Xin Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-7833. Minimum Default = 1, Maximum Default = 7833.
Preliminary Draft Postal Codes - 2D The following lists the possible 2D postal codes, and 2D postal code combinations that are allowed. Only one 2D postal code selection can be active at a time. If you scan a second 2D postal code selection, the first selection is overwritten. Default = 2D Postal Codes Off.
Preliminary Draft Postnet On Also see Postnet Check Digit, page 7-54.
Preliminary Draft Planet Code and Postal-4i On Planet Code and Intelligent Mail Bar Code On Planet Code, Postnet, and Postal-4i On Planet Code, Postnet, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and Intelligent Mail Bar Code On Postnet, Postal-4i, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and Postnet with B and B’ Fields On Planet Code, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On Postal-4i, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On Pla
Preliminary Draft Planet Code Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Planet Code data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Postnet data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit Postal Codes - Linear The following lists linear postal codes.
Preliminary Draft China Post (Hong Kong 2 of 5) On/Off On * Off China Post (Hong Kong 2 of 5) Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80.
Preliminary Draft Korea Post Korea Post On * Off Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data.
8 Preliminary Draft Imaging Commands The scanner is like a digital camera in the way it captures, manipulates, and transfers images. The following commands allow you to alter the way the scanner performs these functions. Single-Use Basis Imaging Commands with their modifiers send instructions to the scanner on a single-use basis, and take effect for a single image capture. Once that capture is complete, the scanner reverts to its imaging default settings.
Preliminary Draft Step 1 - Take a Picture Using IMGSNP Image Snap - IMGSNP An image is taken whenever the hardware button is pressed, or when the Image Snap (IMGSNP) command is processed. The image snap command has many different modifiers that can be used to change the look of the image in memory. Modifiers always begin with numbers and end with a letter (case insensitive). Any number of modifiers may be appended to the IMGSNP command.
Preliminary Draft E - Exposure Exposure is used in Manual Style only (2P), and allows you to set the exposure time. This is similar to setting a shutter speed on a camera. The exposure time determines how long the scanner takes to record an image. On a bright day, exposure times can be very short because plenty of light is available to help record an image. At nighttime, exposure time can increase dramatically due to the near absence of light. Units are 127 microseconds.
Preliminary Draft W - Target White Value Sets the target for the median grayscale value in the captured image. For capturing close-up images of high contrast documents, a lower setting, such as 75, is recommended. Higher settings result in longer exposure times and brighter images, but if the setting is too high, the image may be overexposed. Target White Value is only available when using Photo Style (1P).
Preliminary Draft Step 2 - Ship a Picture Using IMGSHP Image Ship - IMGSHP An image is taken whenever the button is pressed, or when the Image Snap (IMGSNP) command is processed. The last image is always stored in memory. You can “ship” the image by using the IMGSHP command. The image ship commands have many different modifiers that can be used to change the look of the image output. Modifiers affect the image that is transmitted, but do not affect the image in memory.
Preliminary Draft C - Compensation Flattens the image to account for variations in illumination across the image. 0C Compensation disabled (default) 1C Compensation enabled Example of Compensation at 0C: Example of Compensation at 1C: D - Pixel Depth Indicates the number of bits per pixel in the transmitted image (KIM or BMP format only).
Preliminary Draft E - Edge Sharpen An edge sharpen filter cleans up the edges of an image, making it look cleaner and sharper. While edge sharpening does make the image look cleaner, it also removes some fine detail from the original image. The strength of the edge sharpen filter can be entered from 1 to 24. Entering a 23E gives the sharpest edges, but also increases noise in the image.
Preliminary Draft H - Histogram Stretch Increases the contrast of the transmitted image. Not available with some image formats. 0H No stretch (default) 1H Histogram stretch Example of Histogram Stretch at 0H: Example of Histogram Stretch at 1H: I - Invert Image Invert image is used to rotate the image around the X or Y axis.
Preliminary Draft IF- Noise Reduction Used to reduce the salt and pepper noise in an image.
Preliminary Draft J - JPEG Image Quality Sets the desired quality when the JPEG image format is selected. Higher numbers result in higher quality, but larger files. Smaller numbers result in greater amounts of lossy compression, faster transmission times, lower quality, but smaller files.
Preliminary Draft nB The bottom edge of the shipped image corresponds to row n - 1 of the image in memory. Range: 000 - 480. (Default = all rows) Uncropped Image: Example of Image Crop set to 300R: Example of Image Crop set to 200B: Example of Image Crop set to 300L: Example of Image Crop set to 200T: Alternately, specify the number of pixels to cut from the outside margin of the image; thus only the center pixels are transmitted.
Preliminary Draft 1S ship every pixel (default) 2S ship every 2nd pixel, both horizontally and vertically 3S ship every 3rd pixel, both horizontally and vertically Example of Pixel Ship set to 1S: Example of Pixel Ship set to 2S: Example of Pixel Ship set to 3S: U - Document Image Filter Allows you to input parameters to sharpen the edges and smooth the area between the edges of text in an image.
Preliminary Draft V - Blur Image Smooths transitions by averaging the pixels next to the hard edges of defined lines and shaded areas in an image. 0V Don’t blur (default) 1V Blur Example of Blur Image Off (0V): Example of Blur Image On (1V): W - Histogram Ship A histogram gives a quick picture of the tonal range of an image, or key type.
Preliminary Draft Image Size Compatibility If you have applications that expect an image ship to return exactly 640x480 pixels, scan the Force VGA Resolution bar code. Default = Native Resolution Force VGA Resolution * Native Resolution Intelligent Signature Capture - IMGBOX IMGBOX allows you to configure the size and location of a signature capture area relative to its proximity to a bar code. This allows you to tailor a signature capture area to a specific form.
Preliminary Draft The following IMGBOX example was executed and viewed using QuickView software. This software is available at www.honeywellaidc.com. Click on Software Downloads. Select 4600r from the Products list, then select QuickView Software Utility. Below is an example of a signature capture application. In this example, the aimer is centered over the signature capture area and the trigger is pressed.
Preliminary Draft This option is used to size the image horizontally. If using this option, set the resolution (R) to zero. Example of Image Width set to 200A: Example of Image Width set to 600A: B - Output Image Height This option is used to size the image vertically. If using this option, set the resolution (R) to zero.
Preliminary Draft 8F BMP format H - Height of Signature Capture Area The height of the signature capture area must be measured in inches divided by .01. In the example, the height of the area to be captured is 3/8 inch, resulting in a value of H = .375/0.01 = 37.5. Example: IMGBOX245w37h55y. K - Gamma Correction Gamma measures the brightness of midtone values produced by the image. You can brighten or darken an image using gamma correction. A higher gamma correction yields an overall brighter image.
Preliminary Draft For example, use 2500 to specify a resolution of 2.5. Set to zero when using the A and B modifiers (see A - Output Image Width and B - Output Image Height on page 8-16). Example of Resolution set to 0R: Example of Resolution set to 1000R: Example of Resolution set to 2000R: S - Bar Code Aspect Ratio All dimensions used in IMGBOX are measured as multiples of the minimum element size of the bar code.
Preliminary Draft Y - Vertical Bar Code Offset The vertical bar code offset allows you to offset the vertical center of the signature capture area. Negative numbers indicate that the signature capture is above the bar code, and positive numbers indicate that the area is below the bar code. Measurements are in multiples of the minimum bar width.
Preliminary Draft 8 - 20
9 Preliminary Draft Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-19 enable Control + ASCII mode.
Preliminary Draft The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of these five characters for different countries. Country United States Codes [ \ ] 6 - Belgium [ < ] 6 - Scandinavia 8 < 9 6 - France ^ 8 $ 6 = Ã + 6 - Germany Italy \ + 6 - Switzerland < .. 6 - United Kingdom [ ¢ ] 6 - Denmark 8 \ 9 6 - Norway 8 \ 9 6 - Spain [ \ ] 6 - 9-2
Preliminary Draft Supported Interface Keys ASCII HEX IBM AT/XT and PS/2 Compatibles, WYSE PC/AT Supported Keys NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Reserved Enter (KP) Cap Lock ALT make ALT break CTRL make CTRL break CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4
Preliminary Draft ASCII HEX IBM AT/XT and PS/2 Compatibles, WYSE PC/AT Supported Keys IBM XTs and Compatibles Supported Keys * IBM 3191/92, 3471/72, 3196/97, 3476/77, Telex (all models) 9-4 IBM, DDC, Memorex Telex, Harris* Supported Keys
Preliminary Draft Supported Interface Keys ASCII NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US HEX IBM, Memorex Telex (102)* Supported Keys Memorex Telex (88)** Supported Keys 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Reserved Enter F11 F12 F13 F14 F15 New Line F16 F17 F18 Tab/Field Forward Delete Field Exit Insert Clear Error Reset Home Print Back Space Back Tab F19 F1 F2 F3 F4 F5
Preliminary Draft Supported Interface Keys ASCII HEX Esprit 200, 400 ANSI Supported Keys NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 9-6 Esprit 200, 400 ASCII Supported Keys Esprit
Preliminary Draft Supported Interface Keys ASCII HEX Apple Mac/iMac Supported Keys NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US DEL 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 7F Reserved Enter/Numpad Enter CAPS ALT make ALT break CNTRL make CNTRL break RETURN APPLE make TAB APPLE break TAB Del RETURN Ins Help ESC F11 Home Prnt Scrn BACKSPACE LSHIFT TAB F12 F1 F2 F3 F4 F5 F6 F7 F8 F
Preliminary Draft 9-8
10 Preliminary Draft Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, beginning on page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D. prefix for all symbologies. This is a temporary setting that will be removed when the unit is power cycled. Add Code I.D.
Preliminary Draft Show Data Format Scan the bar code below to show current data format settings. DFMBK3?. Data Format Settings Test Menu When you scan the Test Menu On code, then scan a programming code in this manual, the scanner displays the content of a programming code. The programming function will still occur, but in addition, the content of that programming code is output to the terminal. Note: This feature should not be used during normal scanner operation.
Preliminary Draft Application Plug-Ins (Apps) Any apps that you are using can be turned off or on by scanning the following bar codes. Apps are stored in groups: Imaging, Decoding, and Formatting. You can enable and disable these groups of apps by scanning that group’s On or Off bar code below. You can also scan the List Apps bar code to output a list of all your apps.
Preliminary Draft To communicate with a scanner, EZConfig requires that the PC have at least one available serial communication port, or a serial port emulation using a physical USB port. If you are using the serial port and RS232 cable, an external power supply is required. When using a USB serial port emulation, only a USB cable is required.
Preliminary Draft 6. Once you have finished downloading the file, exit the web site. 7. Using Explorer, go to the c:\windows\temp file. 8. Double click on the Setup.exe file. Follow the screen prompts to install the EZConfig program. 9. If you’ve selected the defaults during installation, you can click on Start Menu-All Programs-Honeywell-EZConfig.
Preliminary Draft 10 - 6
11 Preliminary Draft Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the scanner. For complete descriptions and examples of each serial programming command, refer to the corresponding programming bar code in this manual. The device must be set to an RS232 interface (see page 2-2). The following commands can be sent via a PC COM port using terminal emulation software.
Preliminary Draft Storage A single character that specifies the storage table to which the command is applied. An exclamation point (!) performs the command’s operation on the device’s volatile menu configuration table. A period (.) performs the command’s operation on the device’s non-volatile menu configuration table. Use the non-volatile table only for semi-permanent changes you want saved through a power cycle. Query Commands Several special characters can be used to query the device about its settings.
Preliminary Draft Responses The device responds to serial commands with one of three responses: ACK Indicates a good command which has been processed. ENQ Indicates an invalid Tag or SubTag command. NAK Indicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a minimum message length of 100 when the field will only accept 2 characters.
Preliminary Draft MAX60[ACK], DFT[ACK]. This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required; concatenation (CCT) is set to 1, or Enabled; the Minimum Message Length (MIN) is set to 2 characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value.
Preliminary Draft Menu Commands Selection Setting Serial Command # Indicates a numeric entry Page Restore Factory Defaults DEFOVR 1-9 Save Defaults DEFALT 1-9 Set Custom Defaults MNUCDF 1-10 Save Custom Defaults DEFALT 1-10 Resetting the Custom Defaults Custom Product Default Settings: Current Application Group DEFALT 1-10 Resetting the Factory Defaults - cordless scanners Factory Default Settings: All Application Groups PAPDFT& 3-23 Resetting the Custom Defaults cordless scanners C
Preliminary Draft Selection Plug and Play Codes: RS485 Plug and Play Codes: IBM SurePos Plug and Play Codes: USB 11 - 6 Setting Serial Command # Indicates a numeric entry Page IBM Port 5B Interface PAPP5B 2-2 IBM Port 9B HHBCR-1 Interface PAP9B1 2-2 IBM Port 17 Interface PAPP17 2-2 IBM Port 9B HHBCR-2 Interface PAP9B2 2-2 RS485 Packet Mode On RTLPDF1 2-3 RS485 Packet Mode Off RTLPDF0 2-3 RS485 Packet Length (20-256) RTLMPS 2-3 USB IBM SurePos Handheld PAPSPH 2-4 USB IBM SureP
Preliminary Draft Selection Plug and Play Codes Program Keyboard Country Setting Serial Command # Indicates a numeric entry Page Verifone Ruby Terminal PAPRBY 2-6 Gilbarco Terminal PAPGLB 2-7 Honeywell Bioptic Aux Port PAPBIO 2-7 Datalogic Magellan Bioptic Aux Port PAPMAG 2-7 NCR Bioptic Aux Port PAPNCR 2-8 Wincor Nixdorf Terminal PAPWNX 2-8 Wincor Nixdorf Beetle PAPBTL 2-9 *U.S.A.
Preliminary Draft Selection Program Keyboard Country 11 - 8 Setting Serial Command # Indicates a numeric entry Page Czech (Programmers) KBDCTY40 2-11 Czech (QWERTY) KBDCTY39 2-11 Czech (QWERTZ) KBDCTY38 2-11 Denmark KBDCTY8 2-11 Dutch (Netherlands) KBDCTY11 2-11 Estonia KBDCTY41 2-12 Faeroese KBDCTY83 2-12 Finland KBDCTY2 2-12 France KBDCTY3 2-12 Gaelic KBDCTY84 2-12 Germany KBDCTY4 2-12 Greek KBDCTY17 2-12 Greek (220 Latin) KBDCTY64 2-12 Greek (220) KBDCTY61 2
Preliminary Draft Selection Program Keyboard Country Setting Serial Command * Indicates default # Indicates a numeric entry Page Latvia (QWERTY) KBDCTY43 2-14 Lithuania KBDCTY44 2-14 Lithuania (IBM) KBDCTY45 2-14 Macedonia KBDCTY34 2-14 Malta KBDCTY74 2-14 Mongolian (Cyrillic) KBDCTY86 2-14 Norway KBDCTY9 2-14 Poland KBDCTY20 2-14 Polish (214) KBDCTY57 2-14 Polish (Programmers) KBDCTY58 2-14 Portugal KBDCTY13 2-14 Romania KBDCTY25 2-14 Russia KBDCTY26 2-14 Russi
Preliminary Draft Selection Program Keyboard Country Keyboard Conversion Keyboard Style Control Character Output 11 - 10 Setting Serial Command * Indicates default # Indicates a numeric entry Page Ukrainian KBDCTY76 2-16 United Kingdom KBDCTY7 2-16 United Stated (Dvorak right) KBDCTY89 2-16 United States (Dvorak left) KBDCTY88 2-16 United States (Dvorak) KBDCTY87 2-16 United States (International) KBDCTY30 2-16 Uzbek (Cyrillic) KBDCTY77 2-16 *Keyboard Conversion Off KBDCNV0
Preliminary Draft Selection Keyboard Modifiers Baud Rate Setting Serial Command * Indicates default # Indicates a numeric entry Page *Control + ASCII Off KBDCAS0 2-20 DOS Mode Control + ASCII KBDCAS1 2-20 Windows Mode Control + ASCII KBDCAS2 2-20 Windows Mode Prefix/Suffix Off KBDCAS3 2-20 *Turbo Mode Off KBDTMD0 2-20 Turbo Mode On KBDTMD1 2-20 *Numeric Keypad Off KBDNPS0 2-20 Numeric Keypad On KBDNPS1 2-20 *Auto Direct Connect Off KBDADC0 2-21 Auto Direct Connect On KBDA
Preliminary Draft Selection Setting Serial Command * Indicates default # Indicates a numeric entry Page 7 Data, 1 Stop, Parity Even 232WRD3 2-23 7 Data, 1 Stop, Parity None 232WRD0 2-23 7 Data, 1 Stop, Parity Odd 232WRD6 2-23 7 Data, 2 Stop, Parity Even 232WRD4 2-23 7 Data, 2 Stop, Parity None 232WRD1 2-23 7 Data, 2 Stop, Parity Odd 232WRD7 2-23 8 Data, 1 Stop, Parity Even 232WRD5 2-23 *8 Data, 1 Stop, Parity None 232WRD2 2-23 8 Data, 1 Stop, Parity Odd 232WRD8 2-23 RS232 R
Preliminary Draft Selection Scanner-Bioptic ACK/NAK Mode Scanner-Bioptic ACK/NAK Timeout Setting Serial Command # Indicates a numeric entry Page *Bioptic ACK/NAK Off 232NAK0 2-27 Bioptic ACK/NAK On 232NAK1 2-27 ACK/NAK Timeout *5100 232DLK##### 2-27 * Indicates default Cordless System Operation Note: This section applies only to cordless systems. It does not apply to corded scanners.
Preliminary Draft Selection Scanner Modes Single Out-of-Range Alarm Alarm Sound Type Flexible Power Management Batch Mode Batch Mode Beep Batch Mode Storage Batch Mode Quantity 11 - 14 Setting Serial Command * Indicates default # Indicates a numeric entry Page Charge Only Mode BASLNK0 3-10 *Charge and Link Mode BASLNK1 3-10 Locked Link Mode BASCON0,DNG1 3-11 *Open Link Mode BASCON1,DNG1 3-11 Unlink Scanner BT_RMV 3-11 Override Locked Scanner BT_RPL1 3-12 Base Alarm Duration (Ra
Preliminary Draft Selection Quantity Codes Setting Serial Command * Indicates default # Indicates a numeric entry Page 0 BATNUM0 3-17 *1 BATNUM1 3-17 2 BATNUM2 3-17 3 BATNUM3 3-17 4 BATNUM4 3-17 5 BATNUM5 3-17 6 BATNUM6 3-17 7 BATNUM7 3-17 8 BATNUM8 3-18 9 BATNUM9 3-18 Batch Mode Output Order FIFO BATLIF0 3-18 LIFO BATLIF1 3-18 Delete Last Code Delete Last Code BATUND 3-18 Clear All Codes Clear All Codes BATCLR 3-18 Transmit Records to Host Transmit Inven
Preliminary Draft Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Resetting the Custom Defaults: All Application Work Groups Custom Default Settings: All Work Groups PAPDFT 3-24 Bluetooth Connection PCs/Laptops: Non-Base BT Connection BT_DNG5 3-25 BT Connection PDA/Mobility Systems Device BT_DNG1 3-25 Bluetooth PIN Code Bluetooth PIN BT_PIN 3-25 Auto Reconnect Mode *Auto Reconnect On BT_ACM1 3-26 Auto Reconnect Off BT_ACM0 3-26 Maximum Link At
Preliminary Draft Selection Setting Serial Command * Indicates default # Indicates a numeric entry Page Off BEPLVL0 4-2 Low BEPLVL1 4-3 Medium BEPLVL2 4-3 *High BEPLVL3 4-3 Low (1600) (min 400Hz) BEPFQ11600 4-3 *Medium 2700) BEPFQ12700 4-3 High (4200) (max 9000Hz) BEPFQ14200 4-3 *Razz (250) (min 200Hz) BEPFQ2800 4-4 Medium (3250) BEPFQ23250 4-4 High (4200) (max 9000Hz) BEPFQ24200 4-4 Beeper Duration Good Read *Normal Beep BEPBIP0 4-4 Short Beep BEPBIP1 4-4 LED - G
Preliminary Draft Selection Manual/Serial Trigger Modes Setting Serial Command # Indicates a numeric entry Page *Manual Trigger Normal PAPHHF 4-7 Manual Trigger Enhanced PAPHHS 4-7 Read Time-Out (0 - 300,000 ms) *30,000 TRGSTO#### 4-7 Scanner Power Time-Out Timer (07200 seconds) *3600 BT_LPT0 4-8 BT_LPT200 4-8 BT_LPT400 4-8 BT_LPT900 4-8 BT_LPT3600 4-8 BT_LPT7200 4-8 * Indicates default In-Stand Sensor Mode Sensor On TRGSSW1 4-9 Sensor Off TRGSSW0 4-9 Presentation Present
Preliminary Draft Selection Hands Free TimeOut Reread Delay Setting * Indicates default Range 0 - 300,000 ms Serial Command # Indicates a numeric entry Page TRGPTO###### 4-12 Short (500 ms) DLYRRD500 4-12 *Medium (750 ms) DLYRRD750 4-12 Long (1000 ms) DLYRRD1000 4-12 Extra Long (2000 ms) DLYRRD2000 4-12 User-Specified Reread Delay Range 0 - 30,000 ms DLYRRD##### 4-12 Illumination Lights *Lights On SCNLED1 4-13 Lights Off SCNLED0 4-13 200 milliseconds SCNDLY200 4-13 400 mill
Preliminary Draft Setting Serial Command * Indicates default # Indicates a numeric entry Page On PRFENA1 4-17 *Off PRFENA0 4-17 High Priority Symbology PRFCOD## 4-17 Low Priority Symbology PRFBLK## 4-17 Preferred Symbology Timeout (*500) Range 1003000 PRFPTO#### 4-18 Preferred Symbology Default PRFDFT 4-18 Output Sequence Editor Enter Sequence SEQBLK 4-21 Default Sequence SEQDFT 4-21 Partial Sequence Transmit Partial Sequence SEQTTS1 4-21 *Discard Partial Sequence SEQTTS0
Preliminary Draft Selection Prefix Suffix Setting Serial Command * Indicates default # Indicates a numeric entry Page Add Prefix PREBK2## 5-3 Clear One Prefix PRECL2 5-3 Clear All Prefixes PRECA2 5-3 Add Suffix SUFBK2## 5-4 Clear One Suffix SUFCL2 5-4 Clear All Suffixes SUFCA2 5-4 Function Code Transmit *Enable RMVFNC0 5-4 Disable RMVFNC1 5-4 Intercharacter Delay Range 0 - 1000 (5ms increments) DLYCHR## 5-5 User Specified Intercharacter Delay Delay Length 0 - 1000 (5ms
Preliminary Draft Selection Data Formatter Data Format NonMatch Error Tone Primary/Alternate Data Formats Single Scan Data Format Change Setting Serial Command * Indicates default # Indicates a numeric entry Page Data Formatter Off DFM_EN0 6-8 *Data Formatter On, Not Required, Keep Prefix/Suffix DFM_EN1 6-9 Data Format Required, Keep Prefix/Suffix DFM_EN2 6-9 Data Formatter On, Not Required, Drop Prefix/Suffix DFM_EN3 6-9 Data Format Required, Drop Prefix/Suffix DFM_EN4 6-9 *Data Fo
Preliminary Draft Selection Codabar Codabar Start/Stop Char. Codabar Check Char. Codabar Concatenation Setting Serial Command # Indicates a numeric entry Page Default All Codabar Settings CBRDFT 7-3 Off CBRENA0 7-3 *On CBRENA1 7-3 * Indicates default *Don’t Transmit CBRSSX0 7-3 Transmit CBRSSX1 7-3 *No Check Char.
Preliminary Draft Selection Setting Serial Command * Indicates default # Indicates a numeric entry Page Code 32 Pharmaceutical (PARAF) *Off C39B320 7-8 On C39B321 7-8 Code 39 Full ASCII *Off C39ASC0 7-9 On C39ASC1 7-9 Code 39 Code Page C39DCP 7-10 Default All Interleaved 2 of 5 Settings I25DFT 7-10 Off I25ENA0 7-10 *On I25ENA1 7-10 Interleaved 2 of 5 Interleaved 2 of 5 Check Digit *No Check Char.
Preliminary Draft Selection Setting Serial Command # Indicates a numeric entry Page Default All Code 93 Settings C93DFT 7-14 Off C93ENA0 7-14 *On C93ENA1 7-15 Minimum (0 - 80) *0 C93MIN## 7-14 Maximum (0 - 80) *80 C93MAX## 7-14 Code 93 Code Page C93DCP 7-15 Default All Straight 2 of 5 Industrial Settings R25DFT 7-15 *Off R25ENA0 7-15 On R25ENA1 7-15 Straight 2 of 5 Industrial Message Length Minimum (1 - 48) *4 R25MIN## 7-15 Maximum (1 - 48) *48 R25MAX## 7-15 Straight 2
Preliminary Draft Selection Code 11 Code 11 Check Digits Required Code 11 Message Length Code 128 ISBT Concatenation Code 128 Message Length Setting Serial Command # Indicates a numeric entry Page C11DFT 7-18 *Off C11ENA0 7-18 On C11ENA1 7-18 * Indicates default Default All Code 11 Settings 1 Check Digit C11CK20 7-18 *2 Check Digits C11CK21 7-18 Minimum (1 - 80) *4 C11MIN## 7-19 Maximum (1 - 80) *80 C11MAX## 7-19 Default All Code 128 Settings 128DFT 7-19 Off 128ENA0 7-19 *
Preliminary Draft Selection Telepen Output Telepen Message Length UPC-A UPC-A Check Digit UPC-A Number System UPC-A 2 Digit Addenda UPC-A 5 Digit Addenda UPC-A Addenda Required UPC-A Addenda Separator UPC-A/EAN-13 with Extended Coupon Code UPC-E0 UPC-E0 Expand Setting Serial Command * Indicates default # Indicates a numeric entry Page *AIM Telepen Output TELOLD0 7-22 Original Telepen Output TELOLD1 7-22 Minimum (1 - 60) *1 TELMIN## 7-23 Maximum (1 - 60) *60 TELMAX## 7-23 Default All U
Preliminary Draft Selection Setting Serial Command * Indicates default # Indicates a numeric entry Page UPC-E0 Addenda Required Required UPEARQ1 7-27 *Not Required UPEARQ0 7-27 UPC-E0 Addenda Separator *On UPEADS1 7-27 Off UPEADS0 7-27 UPC-E0 Check Digit Off UPECKX0 7-27 *On UPECKX1 7-27 UPC-E0 Number System Off UPENSX0 7-28 *On UPENSX1 7-28 UPC-E0 Addenda 2 Digit Addenda On UPEAD21 7-28 *2 Digit Addenda Off UPEAD20 7-28 5 Digit Addenda On UPEAD51 7-28 *5 Digit A
Preliminary Draft Selection Setting Serial Command # Indicates a numeric entry Page Default All EAN/ JAN 8 Settings EA8DFT 7-32 Off EA8ENA0 7-32 *On EA8ENA1 7-32 Off EA8CKX0 7-32 *On EA8CKX1 7-32 *2 Digit Addenda Off EA8AD20 7-33 2 Digit Addenda On EA8AD21 7-33 *5 Digit Addenda Off EA8AD50 7-33 5 Digit Addenda On EA8AD51 7-33 EAN/JAN-8 Addenda Required *Not Required EA8ARQ0 7-33 Required EA8ARQ1 7-33 EAN/JAN-8 Addenda Separator Off EA8ADS0 7-33 *On EA8ADS1 7-33
Preliminary Draft Selection MSI Check Character MSI Message Length GS1 DataBar Omnidirectional GS1 DataBar Limited 11 - 30 Setting Serial Command # Indicates a numeric entry Page *Validate Type 10, but Don’t Transmit MSICHK0 7-35 Validate Type 10 and Transmit MSICHK1 7-35 Validate 2 Type 10 Chars, but Don’t Transmit MSICHK2 7-35 Validate 2 Type 10 Chars and Transmit MSICHK3 7-35 Validate Type 10 then Type 11 Char, but Don’t Transmit MSICHK4 7-35 Validate Type 10 then Type 11 Char and
Preliminary Draft Selection GS1 DataBar Expanded Setting Serial Command # Indicates a numeric entry Page Default All GS1 DataBar Expanded Settings RSEDFT 7-37 Off RSEENA0 7-37 *On * Indicates default RSEENA1 7-37 GS1 DataBar Expanded Msg.
Preliminary Draft Selection PDF417 Msg. Length MicroPDF417 MicroPDF417 Msg. Length GS1 Composite Codes UPC/EAN Version GS1 Composite Codes Msg.
Preliminary Draft Selection QR Code Msg. Length Data Matrix Data Matrix Msg. Length MaxiCode MaxiCode Msg. Length Aztec Code Aztec Code Msg.
Preliminary Draft Selection Chinese Sensible (Han Xin) Code Msg.
Preliminary Draft Selection Combination 2D Postal Codes (continued) Setting Serial Command # Indicates a numeric entry Page Postal-4i and Postnet with B and B’ Fields On POSTAL19 7-52 Planet and Postnet On POSTAL12 7-52 Planet and Postnet with B and B’ Fields On POSTAL18 7-52 Planet and Postal-4i On POSTAL13 7-53 Planet and Intelligent Mail Bar Code On POSTAL15 7-53 Planet, Postnet, and Postal-4i On POSTAL21 7-53 Planet, Postnet, and Intelligent Mail Bar Code On POSTAL22 7-53 Plane
Preliminary Draft Selection Combination 2D Postal Codes (continued) Planet Code Check Digit Postnet Check Digit Setting Serial Command # Indicates a numeric entry Page Planet, Postal-4i, Intelligent Mail Bar Code, and Postnet On POSTAL28 7-53 Planet, Postal-4i, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On POSTAL29 7-53 Transmit PLNCKX1 7-54 *Don’t Transmit PLNCKX0 7-54 Transmit NETCKX1 7-54 *Don’t Transmit NETCKX0 7-54 Default All China Post (Hong Kong 2 of 5) Setti
Preliminary Draft Selection Setting Serial Command # Indicates a numeric entry Page Default all Imaging Commands IMGDFT 8-1 Imaging Style Decoding SNPSTY0 8-2 *Imaging Style Photo SNPSTY1 8-2 Imaging Style Manual SNPSTY2 8-2 Beeper On SNPBEP1 8-2 *Beeper Off SNPBEP0 8-2 *Wait for Trigger Off SNPTRG0 8-2 Wait for Trigger On SNPTRG1 8-2 *LED State - Off SNPLED0 8-2 LED State - On SNPLED1 8-2 Exposure (1-7874 microseconds) SNPEXP 8-3 *Gain - None SNPGAN1 8-3 Gain - Medi
Preliminary Draft Selection Image Ship 11 - 38 Setting Serial Command * Indicates default # Indicates a numeric entry Page *Infinity Filter - Off IMGINF0 8-5 Infinity Filter - On IMGINF1 8-5 *Compensation Off IMGCOR0 8-6 Compensation On IMGCOR1 8-6 *Pixel Depth - 8 bits/ pixel (grayscale) IMGBPP8 8-6 Pixel Depth - 1 bit/ pixel (B&W) IMGBPP1 8-6 *Don’t Sharpen Edges IMGEDG0 8-7 Sharpen Edges (023) IMGEDG## 8-7 *File Format - JPEG IMGFMT6 8-7 File Format - KIM IMGFMT0 8-7
Preliminary Draft Selection Image Ship (continued) Setting Serial Command # Indicates a numeric entry Page Invert Image around X axis IMGNVX1 8-8 Invert Image around Y axis IMGNVY1 8-8 Rotate Image none IMGROT0 8-9 Rotate Image 90° right IMGROT1 8-9 Rotate Image 180° right IMGROT2 8-9 Rotate Image 90° left IMGROT3 8-9 JPEG Image Quality (0-100) *50 IMGJQF### 8-10 *Gamma Correction Off IMGGAM0 8-10 Gamma Correction On (0-1000) IMGGAM### 8-10 Image Crop - Left (0640) *0 IMGWNL
Preliminary Draft Selection Image Ship (continued) Image Size Compatibility Intelligent Signature Capture 11 - 40 Setting Serial Command * Indicates default # Indicates a numeric entry Page Ship Every 2nd Pixel IMGSUB2 8-12 Ship Every 3rd Pixel IMGSUB3 8-12 *Document Image Filter Off IMGUSH0 8-12 Document Image Filter On (0-255) IMGUSH### 8-12 *Don’t Ship Histogram IMGHST0 8-13 Ship Histogram IMGHST1 8-13 Force VGA Resolution IMGVGA1 8-14 *Native Resolution IMGVGA0 8-14 Opti
12 Preliminary Draft Product Specifications 1900 Scanner Product Specifications Parameter Specification Dimensions (Typical): Height 6.3 inches (16 cm) Length 4.1 inches (10.41cm) Width 2.8 inches (7.11cm) Weight 5.2 ounces (147.42g) Illumination: Scan and Aiming LEDs LED output power 617nm + 18nm .339mW Image Size 838 x 640 pixels Skew Angle +65° Pitch Angle +45° Motion Tolerance: Streaming Presentation Trigger up to 240 inches per second for 13 mil UPC Symbol Contrast Grade 1.
Preliminary Draft 1902 Scanner Product Specifications Parameter Specification Dimensions (Typical): Height 6.3 inches (16 cm) Length 4.1 inches (10.41cm) Width 2.8 inches (7.11cm) Weight 7.5 ounces (212.62g) Illumination: Scan and Aiming LEDs LED output power 617nm + 18nm .339mW Image Size 838 x 640 pixels Skew Angle +65° Pitch Angle +45° Motion Tolerance: Streaming Presentation Trigger up to 240 inches per second for 13 mil UPC Symbol Contrast Grade 1.
Preliminary Draft CCB01-010BT Charge Base Product Specifications Parameter Specification Dimensions (Typical): Height 3.2 inches (8.128cm) Length 5.19 inches (13.183cm) Width 3.98 inches (10.109cm) Weight 6.3 oz (179g) Voltage: 4.5 to 5.5 volts Current Draw: Host Terminal Port 500mA Aux Power Port 1A Charge Time 5 hours Radio: Frequency 2.4 to 2.5 GHz (ISM Band) Frequency Hopping Bluetooth v.2.1 Range 33 ft.
12 - 4 Cable shield Cable select Supply ground Terminal data Terminal clock Keyboard clock Supply power input +5V power Keyboard data Note: Pin assignments are not compatible with Honeywell legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty.
Cable shield Cable select Supply ground Transmit data Receive data - serial data to scanner CTS +5V power RTS Note: Pin assignments are not compatible with Honeywell legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty.
12 - 6 +5V power Transmit Enable Cable shield Cable select Supply ground Transmit data Receive data - serial data to scanner Note: RS485 signal conversion is performed in the cable. Pin assignments are not compatible with Honeywell legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty.
1 2 3 4 5 6 7 8 9 10 Data + Data - +5V power Cable shield Cable select Supply ground Note: Pin assignments are not compatible with Honeywell legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty.
Preliminary Draft 12 - 8
13 Preliminary Draft Maintenance Repairs Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center (see Customer Support on page 14-1). Maintenance Your device provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable operation: Cleaning the Device Reading performance may degrade if the scanner’s window is not clean.
Preliminary Draft • Order replacement cables from Honeywell or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable. Replacing an Interface Cable 1. Turn the power to the host system OFF. 2. Disconnect the scanner’s cable from the terminal or computer. 3. Locate the small hole on the back of the scanner’s handle. This is the cable release. 4. Straighten one end of a paper clip. 5.
Preliminary Draft and press firmly. The connector is keyed to go in only one way, and will click into place. Changing a scanner Battery 1. Loosen the thumbwheel screw on the end cap by hand or use a hex wrench. 2. Remove the battery from the handle. 3. Insert replacement battery. 4. Replace end cap and screw. Troubleshooting a Xenon Scanner End Cap The scanner automatically performs self-tests whenever you turn it on.
Preliminary Draft If the scanner reads a bar code, but the data is not displayed correctly on the host screen: • The scanner may not be programmed for the appropriate terminal interface. For example, you scan “12345” and the host displays “@es%.” Reprogram the scanner with the correct Plug and Play bar code. See Programming the Interface beginning on page 2-1. • The scanner may not be programmed to output your bar code data properly. For example, you scan “12345” and the host displays “A12345B.
Preliminary Draft • The battery is not bad or deeply discharged. In some cases, the scanner’s battery may trickle charge to bring it into an acceptable level and then transition to a normal charge cycle. Troubleshooting a Cordless Scanner Note: Make sure that your scanner’s battery is charged. Visit the Services and Support section of our website (www.honeywellaidc.com) to check for the latest software for both the scanner and the base.
Preliminary Draft 13 - 6
14 Preliminary Draft Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 E-mail: hsmnasupport@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (11) 5185-8222 Fax: +55 (11) 5185-8225 E-mail: brsuporte@honeywell.
Preliminary Draft Online Technical Assistance You can also access technical assistance online at www.honeywellaidc.com. Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product. North America Telephone: (800) 782-4263 E-mail: hsmnaservice@honeywell.
Preliminary Draft Japan Telephone: +81-3-3839-8511 Fax: +81-3-3839-8519 E-mail: apservice@honeywell.com Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.honeywellaidc.com. Limited Warranty Honeywell International Inc. ("HII") warrants its products to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment.
Preliminary Draft HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. SOME STATES, PROVINCES, OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unenforceable, such determination shall not affect the validity of enforceability of the other provisions hereof.
A Preliminary Draft Reference Charts Symbology Chart Symbology AIM ID Possible AIM ID Modifiers ( m) All Symbologies Code ID (hex) (0x99) Australian Post ]X0 Aztec Code ]zm British Post ]X0 B (0x42) Canadian Post ]X0 C (0x43) China Post ]X0 Q (0x51) Chinese Sensible Code (Han Xin Code) ]X0 H (0x48) Codabar ]Fm 0-1 a (0x61) Codablock A ]Om 0, 1, 4, 5, 6 V (0x56) Codablock F ]Om 0, 1, 4, 5, 6 q (0x71) Code 11 ]H3 Code 128 ]Cm GS1-128 A (0x41) 0-9, A-C z (0x7A) h (0x68
Preliminary Draft Symbology EAN-8 with Add-On GS1 Composite AIM ID Possible AIM ID Modifiers ( m) ]E3 Code ID (hex) D (0x44) ]em 0-3 y (0x79) 0 y (0x79) GS1 DataBar ]em InfoMail ]X0 , (0x2c) Intelligent Mail Barcode ]X0 M (0x4D) Interleaved 2 of 5 ]Im 0, 1, 3 e (0x65) Japanese Post ]X0 J (0x4A) KIX (Netherlands) Post ]X0 K (0x4B) Korea Post ]X0 ? (0x3F) Matrix 2 of 5 ]X0 m (0x6D) MaxiCode ]Um 0-3 x (0x7 8) MicroPDF417 ]Lm 3-5 R (0x52) MSI ]Mm 0 g (0x67) NEC 2
Preliminary Draft Symbology AIM ID Possible AIM ID Modifiers (m) Code ID (hex) UPC-A with Add-On ]E3 c (0x63) UPC-A with Extended Coupon Code ]E3 c (0x63) ]E0 E (0x45) UPC-E with Add-On ]E3 E (0x45) UPC-E1 ]X0 E (0x45) UPC-E Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier character details. Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry.
Preliminary Draft ASCII Conversion Chart (Code Page 1252) Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings.
Preliminary Draft Dec Hex Char Dec Hex Char Dec Hex 160 A0 192 C0 À 224 E0 à 161 A1 ¡ 193 C1 Á 225 E1 á 162 A2 ¢ 194 C2 Â 226 E2 â ƒ 163 A3 £ 195 C3 Ã 227 E3 ã 84 „ 164 A4 ¤ 196 C4 Ä 228 E4 ä 85 … 165 A5 ¥ 197 C5 Å 229 E5 å 134 86 † 166 A6 ¦ 198 C6 Æ 230 E6 æ 135 87 ‡ 167 A7 § 199 C7 Ç 231 E7 ç 136 88 ˆ 168 A8 ¨ 200 C8 È 232 E8 è 137 89 ‰ 169 A9 © 201 C9 É 233 E9 é 138 8A Š 170 AA ª 202 CA
Preliminary Draft Code Page Mapping of Printed Barcodes Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, select the code page with which the barcodes were created. The data characters should then appear properly.
Preliminary Draft
Preliminary Draft
Preliminary Draft Sample Symbols UPC-A 0 123456 7890 Code 128 Code 128 Code 39 BC321 Code 93 123456-9$ Interleaved 2 of 5 1234567890 EAN-13 9 780330 290951 Codabar A13579B Straight 2 of 5 Industrial 123456
Preliminary Draft Sample Symbols Matrix 2 of 5 GS1 DataBar 6543210 PDF417 (01)00123456789012 Car Registration Postnet Zip Code Data Matrix QR Code Test Symbol Numbers 4-CB (4-State Customer Bar Code) 01,234,567094,987654321,01234567891 ID-tag (UPU 4-State) J18CUSA8E6N062315014880T
Preliminary Draft Sample Symbols Aztec Micro PDF417 Package Label MaxiCode Test Message Test Message
Preliminary Draft Programming Chart 0 1 2 3 4 5 6 7 8 9
Preliminary Draft Programming Chart A B C D E F Save Discard Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
Preliminary Draft Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 Xenon-UG Rev (b) 5/10