User's Guide
Table Of Contents
- Voyager™ 1200g/1202g/1202g-BF User’s Guide
- Table of Contents
- Getting Started
- Programming the Interface
- Introduction
- Programming the Interface - Plug and Play
- USB Serial Commands
- Verifone® Ruby Terminal Default Settings
- Gilbarco® Terminal Default Settings
- Honeywell Bioptic Aux Port Configuration
- Datalogic™ Magellan© Bioptic Aux Port Configuration
- NCR Bioptic Aux Port Configuration
- Wincor Nixdorf Terminal Default Settings
- Wincor Nixdorf Beetle™ Terminal Default Settings
- Wincor Nixdorf RS232 Mode A
- Keyboard Country Layout
- Keyboard Wedge Modifiers
- RS232 Modifiers
- NCR Modifiers
- Scanner to Bioptic Communication
- Cordless System Operation (Voyager 1202g)
- How the Charge and Communications Base Works
- Linking the Scanner to a Base
- Communication Between the Cordless System and the Host
- RF (Radio Frequency) Module Operation
- System Conditions
- Page Button
- About the Battery
- Voyager 1202g Battery Removal
- Flash Updates
- Beeper and LED Sequences and Meaning
- Reset Scanner
- Scanning While in Base Cradle
- Base Charging Modes
- Paging
- Scanner Address
- Base Address
- Scanner Modes
- Unlinking the Scanner
- Override Locked Scanner
- Out-of-Range Alarm
- Scanner Power Time-Out Timer
- RangeGate
- Batch Mode
- Scanner Name
- Using the Scanner with Bluetooth Devices
- Minimizing Bluetooth/ISM Band Network Activity
- Reset Scanner and Base
- Cordless System Operation (Voyager 1202g-BF)
- How the Charge and Communications Base Works
- Linking the Scanner to a Base
- Communication Between the Cordless System and the Host
- RF (Radio Frequency) Module Operation
- System Conditions
- About the Instant Charge Pack
- Flash Updates
- Beeper and LED Sequences and Meaning
- Reset Scanner
- Scanning While in Base Cradle
- Paging
- Scanner Address
- Base Address
- Scanner Modes
- Unlinking the Scanner
- Override Locked Scanner
- Out-of-Range Alarm
- Using the Scanner with Bluetooth Devices
- Minimizing Bluetooth/ISM Band Network Activity
- Reset Scanner and Base
- Input/Output Settings
- Data Editing
- Data Formatting
- Symbologies
- All Symbologies
- Message Length Description
- Codabar
- Code 39
- Interleaved 2 of 5
- NEC 2 of 5
- Code 93
- Straight 2 of 5 Industrial (three-bar start/stop)
- Straight 2 of 5 IATA (two-bar start/stop)
- Matrix 2 of 5
- Code 11
- Code 128
- GS1-128
- Telepen
- UPC-A
- UPC-A/EAN-13 with Extended Coupon Code
- UPC-E0
- EAN/JAN-13
- EAN/JAN-8
- MSI
- Plessey Code
- GS1 DataBar Omnidirectional
- GS1 DataBar Limited
- GS1 DataBar Expanded
- Trioptic Code
- GS1 Emulation
- Postal Codes
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance and Troubleshooting
- Reference Charts
12 - 3
6. Replace with the new cable.
Insert the connector into the opening and press firmly. The connector is keyed to go in only one way, and will click into
place.
Troubleshooting a Voyager Scanner
The scanner automatically performs self-tests whenever you turn it on. If your scanner is not functioning properly, review
the following Troubleshooting Guide to try to isolate the problem.
Note: Visit our website (www.honeywellaidc.com) to check for the latest software for the scanner or the base.
Is the power on? Is the laser aimer on?
If the laser aimer isn’t illuminated, check that:
• The cable is connected properly.
• The host system power is on (if external power isn’t used).
• The button works.
Is the scanner having trouble reading your symbols?
If the scanner isn’t reading symbols well, check that the scanner window is clean and that the symbols:
• Aren’t smeared, rough, scratched, or exhibiting voids.
• Aren’t coated with frost or water droplets on the surface.
• Are enabled in the scanner or in the decoder to which the scanner connects.
Is the bar code displayed but not entered?
The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or
the Tab key, for example).
• You need to program a suffix. Programming a suffix enables the scanner to output the bar code data plus the key you
need (such as “CR”) to enter the data into your application. Refer to Prefix/Suffix Overview on page 6-1 for further
information.
The scanner won’t read your bar code at all.
1. Scan the sample bar codes in the back of this manual. If the scanner reads the sample bar codes, check that your bar
code is readable.
Verify that your bar code symbology is enabled (see Chapter 8).
2. If the scanner still can’t read the sample bar codes, scan All Symbologies On, page 8-1.
The cordless scanner won’t scan bar codes while it is in the base.
1. Scanning While in Cradle Off may be programmed.
2. Scan the * Scanning in Cradle On (page 3-6) bar code so the scanner will also scan bar codes while in the base.