User Manual
Table Of Contents
- Voyager 1250g User's Guide
- Table of Contents
- Getting Started
- Programming the Interface
- Introduction
- Programming the Interface - Plug and Play
- USB Serial Commands
- Verifone® Ruby Terminal Default Settings
- Gilbarco® Terminal Default Settings
- Honeywell Bioptic Aux Port Configuration
- Datalogic™ Magellan© Bioptic Aux Port Configuration
- NCR Bioptic Aux Port Configuration
- Wincor Nixdorf Terminal Default Settings
- Wincor Nixdorf Beetle™ Terminal Default Settings
- Wincor Nixdorf RS232 Mode A
- Keyboard Country Layout
- Keyboard Wedge Modifiers
- RS232 Modifiers
- NCR Modifiers
- Scanner to Bioptic Communication
- Input/Output Settings
- Data Editing
- Data Formatting
- Symbologies
- All Symbologies
- Message Length Description
- Codabar
- Code 39
- Interleaved 2 of 5
- NEC 2 of 5
- Code 93
- Straight 2 of 5 Industrial (three-bar start/stop)
- Straight 2 of 5 IATA (two-bar start/stop)
- Matrix 2 of 5
- Code 11
- Code 128
- ISBT 128
- GS1-128
- Telepen
- UPC-A
- UPC-A/EAN-13 with Extended Coupon Code
- UPC-E0
- EAN/JAN-13
- EAN-13 Beginning with 2 Addenda Required
- EAN-13 Beginning with 290 Addenda Required
- EAN-13 Beginning with 378/379 Addenda Required
- EAN-13 Beginning with 414/419 Addenda Required
- EAN-13 Beginning with 434/439 Addenda Required
- EAN-13 Beginning with 977 Addenda Required
- EAN-13 Beginning with 978 Addenda Required
- EAN-13 Beginning with 979 Addenda Required
- ISBN Translate
- ISSN Translate
- EAN/JAN-8
- MSI
- Plessey Code
- GS1 DataBar Omnidirectional
- GS1 DataBar Limited
- GS1 DataBar Expanded
- Trioptic Code
- GS1 Emulation
- Postal Codes
- Interface Keys
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance
- Customer Support
- Reference Charts
- Sample Symbols
- Programming Chart
9 - 27
Codabar Check
Char.
*No Check Char. CBRCK20 6-4
Validate Modulo 16,
But Don’t Transmit
CBRCK21 6-4
Validate Modulo 16,
and Transmit
CBRCK22 6-4
Validate Modulo 7
CD, But Don’t
Transmi t
CBRCK23 6-4
Validate Modulo 7
CD, and Transmit
CBRCK24 6-4
Validate CLSI, But
Don’t Transmit
CBRCK25 6-4
Validate CLSI, and
Transmi t
CBRCK26 6-4
Codabar
Concatenation
*Off CBRCCT0 6-5
On CBRCCT1 6-5
Require CBRCCT2 6-5
Concatenation
Timeout
DLYCCT 6-5
Codabar
Redundancy
Range (0 - 10) *0 CBRVOT## 6-5
Codabar Message
Length
Minimum (1 - 80) *3 CBRMIN## 6-6
Maximum (1 - 80)
*80
CBRMAX## 6-6
Code 39 Default All Code 39
Settings
C39DFT 6-7
Off C39ENA0 6-7
*On C39ENA1 6-7
Code 39 Start/Stop
Char.
*Don’t Transmit C39SSX0 6-7
Transmit C39SSX1 6-7
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric
entry
Page