User Manual
Table Of Contents
- Hyperion 1300g User's Guide
- Getting Started
- Programming the Interface
- Input/Output Settings
- Data Editing
- Data Formatting
- Symbologies
- Introduction
- All Symbologies
- Codabar Start / Stop Characters
- Codabar Check Character
- Codabar Concatenation
- Codabar Message Length
- Code 39 Start / Stop Characters
- Code 39 Check Character
- Code 39 Message Length
- Code 39 Append
- Full ASCII
- Code 39 Code Page
- Check Digit
- Interleaved 2 of 5 Message Length
- Code 93 Message Length
- Code 93 Code Page
- Straight 2 of 5 Industrial Message Length
- Straight 2 of 5 IATA Message Length
- Matrix 2 of 5 Message Length
- Check Digits Required
- Code 11 Message Length
- ISBT 128 Concatenation
- Code 128 Message Length
- Code 128 Code Page
- Code 128 Function Code Transmit
- Telepen Output
- Telepen Message Length
- UPC A Check Digit
- UPC A Number System
- UPC A Addenda
- UPC A Addenda Required
- UPC A Addenda Separator
- UPC E0 and UPC E1
- UPC E0 and UPC E1 Expand
- UPC E0 and UPC E1 Addenda Required
- UPC E0 and UPC E1 Addenda Separator
- UPC E0 Check Digit
- UPC E0 Number System
- UPC E0 Addenda
- EAN/JAN 13 Check Digit
- EAN/JAN 13 Addenda
- EAN/JAN 13 Addenda Required
- EAN/JAN 13 Addenda Separator
- ISBN Translate
- EAN/JAN 8 Check Digit
- EAN/JAN 8 Addenda
- EAN/JAN 8 Addenda Required
- EAN/JAN 8 Addenda Separator
- MSI Check Character
- MSI Message Length
- Plessey Message Length
- GS1 DataBar Expanded Message Length
- Korea Post Message Length
- Codablock F Message Length
- Code 49 Message Length
- Interface Keys
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance
- Customer Support
2 - 25
RTS/CTS Off, RTS Inactive: RTS/CTS is turned off so no data flow control is
used and RTS is inactive.
Flow Control, No Timeout: The scanner asserts RTS when it has data to
send, and will wait indefinitely for CTS to be asserted by the host.
Character-Based Flow Control, No Timeout: The scanner asserts RTS when
it has a character to send, and will wait indefinitely for CTS to be asserted by the
host
Two-Direction Flow Control: The scanner asserts RTS when it is OK for the
host to transmit. The host asserts CTS when it is OK for the device to transmit.
Flow Control with Timeout: The scanner asserts RTS when it has data to
send and waits for a delay (see RS232 Timeout on page 2-27) for CTS to be
asserted by the host. If the delay time expires and CTS is not asserted, the
device transmit buffer is cleared and scanning may resume.
Character-Based Flow Control with Timeout: The scanner asserts RTS
when it has a character to send and waits for a delay (see RS232 Timeout on
page 2-27) for CTS to be asserted by the host. If the delay time expires and
CTS is not asserted, the device transmit buffer is cleared and scanning may
resume.
CTS-Based Flow Control, No Timeout: When the host asserts CTS, scan-
ning is enabled. When CTS is not asserted, scanning is disabled.
RTS On: RTS only is on during transmission. CTS is ignored.
Default = RTS/CTS Off.
* RTS/CTS Off
RTS/CTS Off, RTS Inactive
Flow Control, No Timeout