User Manual
Table Of Contents
- Hyperion 1300g User's Guide
- Getting Started
- Programming the Interface
- Input/Output Settings
- Data Editing
- Data Formatting
- Symbologies
- Introduction
- All Symbologies
- Codabar Start / Stop Characters
- Codabar Check Character
- Codabar Concatenation
- Codabar Message Length
- Code 39 Start / Stop Characters
- Code 39 Check Character
- Code 39 Message Length
- Code 39 Append
- Full ASCII
- Code 39 Code Page
- Check Digit
- Interleaved 2 of 5 Message Length
- Code 93 Message Length
- Code 93 Code Page
- Straight 2 of 5 Industrial Message Length
- Straight 2 of 5 IATA Message Length
- Matrix 2 of 5 Message Length
- Check Digits Required
- Code 11 Message Length
- ISBT 128 Concatenation
- Code 128 Message Length
- Code 128 Code Page
- Code 128 Function Code Transmit
- Telepen Output
- Telepen Message Length
- UPC A Check Digit
- UPC A Number System
- UPC A Addenda
- UPC A Addenda Required
- UPC A Addenda Separator
- UPC E0 and UPC E1
- UPC E0 and UPC E1 Expand
- UPC E0 and UPC E1 Addenda Required
- UPC E0 and UPC E1 Addenda Separator
- UPC E0 Check Digit
- UPC E0 Number System
- UPC E0 Addenda
- EAN/JAN 13 Check Digit
- EAN/JAN 13 Addenda
- EAN/JAN 13 Addenda Required
- EAN/JAN 13 Addenda Separator
- ISBN Translate
- EAN/JAN 8 Check Digit
- EAN/JAN 8 Addenda
- EAN/JAN 8 Addenda Required
- EAN/JAN 8 Addenda Separator
- MSI Check Character
- MSI Message Length
- Plessey Message Length
- GS1 DataBar Expanded Message Length
- Korea Post Message Length
- Codablock F Message Length
- Code 49 Message Length
- Interface Keys
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance
- Customer Support
2 - 27
RS232 Timeout
When using Flow Control with Timeout, you must program the length of the
delay you want to wait for CTS from the host. Set the length (in milliseconds) for
a timeout by scanning the bar code below, then setting the timeout (from 1-
65535 milliseconds) by scanning digits from the inside back cover, then scan-
ning Save. Default = 1000.
XON/XOFF
Standard ASCII control characters can be used to tell the scanner to start send-
ing data (XON/XOFF On) or to stop sending data (XON/XOFF Off). When the
host sends the XOFF character (DC3, hex 13) to the scanner, data transmission
stops. To resume transmission, the host sends the XON character (DC1, hex
11). Data transmission continues where it left off when XOFF was sent. Default
= XON/XOFF Off.
ACK/NAK
After transmitting data, the scanner waits for an ACK character (hex 06) or a
NAK character (hex 15) response from the host. If ACK is received, the commu-
nications cycle is completed and the scanner looks for more bar codes. If NAK
is received, the last set of bar code data is retransmitted and the scanner waits
RS232 Timeout
* XON/OFF Off
XON/XOFF On