User Manual
Table Of Contents
- Hyperion 1300g User's Guide
- Getting Started
- Programming the Interface
- Input/Output Settings
- Data Editing
- Data Formatting
- Symbologies
- Introduction
- All Symbologies
- Codabar Start / Stop Characters
- Codabar Check Character
- Codabar Concatenation
- Codabar Message Length
- Code 39 Start / Stop Characters
- Code 39 Check Character
- Code 39 Message Length
- Code 39 Append
- Full ASCII
- Code 39 Code Page
- Check Digit
- Interleaved 2 of 5 Message Length
- Code 93 Message Length
- Code 93 Code Page
- Straight 2 of 5 Industrial Message Length
- Straight 2 of 5 IATA Message Length
- Matrix 2 of 5 Message Length
- Check Digits Required
- Code 11 Message Length
- ISBT 128 Concatenation
- Code 128 Message Length
- Code 128 Code Page
- Code 128 Function Code Transmit
- Telepen Output
- Telepen Message Length
- UPC A Check Digit
- UPC A Number System
- UPC A Addenda
- UPC A Addenda Required
- UPC A Addenda Separator
- UPC E0 and UPC E1
- UPC E0 and UPC E1 Expand
- UPC E0 and UPC E1 Addenda Required
- UPC E0 and UPC E1 Addenda Separator
- UPC E0 Check Digit
- UPC E0 Number System
- UPC E0 Addenda
- EAN/JAN 13 Check Digit
- EAN/JAN 13 Addenda
- EAN/JAN 13 Addenda Required
- EAN/JAN 13 Addenda Separator
- ISBN Translate
- EAN/JAN 8 Check Digit
- EAN/JAN 8 Addenda
- EAN/JAN 8 Addenda Required
- EAN/JAN 8 Addenda Separator
- MSI Check Character
- MSI Message Length
- Plessey Message Length
- GS1 DataBar Expanded Message Length
- Korea Post Message Length
- Codablock F Message Length
- Code 49 Message Length
- Interface Keys
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance
- Customer Support
3 - 10
Output Sequence Overview
Output Sequence Editor
This programming selection allows you to program the scanner to output data
(when scanning more than one symbol) in whatever order your application
requires, regardless of the order in which the bar codes are scanned. Reading
the Default Sequence symbol programs the scanner to the Universal values,
shown below. These are the defaults. Be certain you want to delete or clear all
formats before you read the Default Sequence symbol.
Note: To make Output Sequence Editor selections, you’ll need to know the
code I.D., code length, and character match(es) your application
requires. Use the Alphanumeric symbols (inside back cover) to read
these options.
Note: You must hold the trigger while reading each bar code in a sequence.
To Add an Output Sequence
1. Scan the Enter Sequence symbol (see Require Output Sequence, page 3-
13).
2. Code I.D.
On the Symbology Charts on page A-1, find the symbology to which you
want to apply the output sequence format. Locate the Hex value for that
symbology and scan the 2 digit hex value from the Programming Chart
(inside back cover).
3. Length
Specify what length (up to 9999 characters) of data output will be acceptable
for this symbology. Scan the four digit data length from the Programming
Chart. (Note: 50 characters is entered as 0050. 9999 is a universal num-
ber, indicating all lengths.) When calculating the length, you must count any
programmed prefixes, suffixes, or formatted characters as part of the length
(unless using 9999).
4. Character Match Sequences
On the ASCII Conversion Chart (Code Page 1252), page A-3, find the Hex
value that represents the character(s) you want to match. Use the Program-
ming Chart to read the alphanumeric combination that represents the ASCII
characters. (99 is the Universal number, indicating all characters.)
5. End Output Sequence Editor
Scan F F to enter an Output Sequence for an additional symbology, or Save
to save your entries.
Other Programming Selections
•Discard
This exits without saving any Output Sequence changes.