User Manual
Table Of Contents
- Hyperion 1300g User's Guide
- Getting Started
- Programming the Interface
- Input/Output Settings
- Data Editing
- Data Formatting
- Symbologies
- Introduction
- All Symbologies
- Codabar Start / Stop Characters
- Codabar Check Character
- Codabar Concatenation
- Codabar Message Length
- Code 39 Start / Stop Characters
- Code 39 Check Character
- Code 39 Message Length
- Code 39 Append
- Full ASCII
- Code 39 Code Page
- Check Digit
- Interleaved 2 of 5 Message Length
- Code 93 Message Length
- Code 93 Code Page
- Straight 2 of 5 Industrial Message Length
- Straight 2 of 5 IATA Message Length
- Matrix 2 of 5 Message Length
- Check Digits Required
- Code 11 Message Length
- ISBT 128 Concatenation
- Code 128 Message Length
- Code 128 Code Page
- Code 128 Function Code Transmit
- Telepen Output
- Telepen Message Length
- UPC A Check Digit
- UPC A Number System
- UPC A Addenda
- UPC A Addenda Required
- UPC A Addenda Separator
- UPC E0 and UPC E1
- UPC E0 and UPC E1 Expand
- UPC E0 and UPC E1 Addenda Required
- UPC E0 and UPC E1 Addenda Separator
- UPC E0 Check Digit
- UPC E0 Number System
- UPC E0 Addenda
- EAN/JAN 13 Check Digit
- EAN/JAN 13 Addenda
- EAN/JAN 13 Addenda Required
- EAN/JAN 13 Addenda Separator
- ISBN Translate
- EAN/JAN 8 Check Digit
- EAN/JAN 8 Addenda
- EAN/JAN 8 Addenda Required
- EAN/JAN 8 Addenda Separator
- MSI Check Character
- MSI Message Length
- Plessey Message Length
- GS1 DataBar Expanded Message Length
- Korea Post Message Length
- Codablock F Message Length
- Code 49 Message Length
- Interface Keys
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance
- Customer Support
4 - 8
To remove this delay, scan the Delay Length bar code, and set the number of
steps to 0. Scan the Save bar code using the inside the back cover of this
manual.
Interfunction Delay
An interfunction delay of up to 495 milliseconds may be placed between the
transmission of each control character in the message string. Scan the Inter-
function Delay bar code below, then scan the number of steps in 5 millisecond
increments and the Save bar code using the inside the back cover of this man-
ual.
To remove this delay, scan the Interfunction Delay bar code, then set the num-
ber of steps to 0. Scan the Save bar code using the inside the back cover of
this manual.
Intermessage Delay
An intermessage delay of up to 495 milliseconds may be placed between each
scan transmission. Scan the Intermessage Delay bar code below, then scan
the number of steps in 5 millisecond increments and the Save bar code using
the inside the back cover of this manual.
Interfunction Delays
Prefix Scanned Data Suffix
1 2345STX HT CR LF
Interfunction Delay
2nd Scan Transmission1st Scan Transmission
Intermessage Delay
Intermessage Delay