User's Guide

174 HH1800 User Guide
Selection
Setting
* Indicates default
Serial Command # Indicates a
numeric entry
Page
Character Activation Mode
*Off
HSTCEN0
35
On
HSTCEN1
35
Activation Character (Range 0- 255) *12 [DC2]
HSTACH###
35
Do Not End Character Activation After Good
Read
HSTCGD0
35
End Character Activation After Good Read
HSTCGD1
35
Character Activation Timeout (Range 1 -
300,000) *30,000 ms
HSTCDT######
36
Character Deactivation Mode
*Off
HSTDEN0
36
On
HSTDEN1
36
Deactivation Character (Range 0- 255) *14
[DC4]
HSTDCH###
36
Illumination Lights
*Lights On
SCNLED1
36
Lights Off
SCNLED0
36
Aimer Delay
1 millisecond
SCNDLY1
37
250 milliseconds
SCNDLY250
37
500 milliseconds
SCNDLY500
37
*Off (no delay)
SCNDLY0
37
User-Specified Aimer Delay
Range 0 - 4,000 ms
SCNDLY####
37
Aimer Mode
Off
SCNAIM0
37
*On
SCNAIM3
37
Single Code Centering
Single Code Centering
DECWIN1;DECTOP49;DECBOT
51;DECRGT51;DECLFT49
38
Centering Window
Centering On
DECWIN1
39
*Centering Off
DECWIN0
39
Left of Centering Window (*40%)
DECLFT###
39
Right of Centering Window (*60%)
DECRGT###
39
Top of Centering Window (*40%)
DECTOP###
39
Bottom of Centering Window (*60%)
DECBOT###
39
Preferred Symbology
On
PRFENA1
40
*Off
PRFENA0
40
High Priority Symbology
PRFCOD##
40
Low Priority Symbology
PRFBLK##
41
Preferred Symbology Timeout (Range
100-3000) *500
PRFPTO####
41
Preferred Symbology Default
PRFDFT
41
Output Sequence Editor
Enter Output Sequence
SEQBLK
46
*Discard Partial Output Sequence
SEQTTS0
48
Default Output Sequence
SEQDFT
49