User's Guide

194 HH1800 User Guide
Parameter (Continued)
Specification
Mechanical Drop
Withstands 1.2m drops (2 times)
ESD Tolerance
Up to 15kV direct air
Up to 8 kV indirect coupling plane
Sealant Rating
IP40
Image
Image Size
1280 x 800 pixels
Scan Performance
Skew Angle
+65°
Pitch Angle
+60°
Motion Tolerance
Up to 75 cm/s for 13 mil UPC at optimal focus
Symbol Contrast
25% or greater (Grade A)
Scan Angle
Horizontal: 48°; Vertical: 30°
Depth of Field Charts
Typical Performance
Symbology
Near Distance/mm
Far Distance/mm
5 mil Code 39
40
225
6.7mil PDF417
50
210
10mil Data Matrix
45
185
13mil UPC-A
35
430
20mil QR Code
20
355
Resolution (Code 39)
3mil
Resolution (PDF 417)
4mi
Resolution (QR)
6mil
Resolution (DM)
5mil