User Manual

90 Xenon XP User Guide
Trigger Number
This sets the number of trigger preses required to activate the Trigger Toggle Mode.
Trigger Timing
This sets the timing of the trigger presses in order to qualify as a trigger toggle,
rather than a regular trigger press. After scanning the Trigger Timing bar code, set
the time-out duration (from 50-2,000 milliseconds) by scanning digits from the
Programming Chart, beginning on page 309, then Save. Default = 400ms.
Trigger Toggle Timeout
This sets the length of time the scanner stays in trigger toggle mode before revert-
ing to scan mode. After scanning the Trigger Toggle Timeout bar code, set the
time-out duration (from 0 to 65 seconds) by scanning digits from the
Programming Chart, beginning on page 309, then Save. Default = 5 seconds.
Note: If this is set to 0, you must repeat the toggle sequence to return to the default
scanning mode. For example, if 2 quick trigger presses puts the scanner into
centering mode and the Trigger Timing is 0, you would have to do 2 quick presses
again to go back to the default scanning mode.
2 Quick Triggers
3 Quick Triggers
4 Quick Triggers
Trigger Timing
Trigger Toggle Timeout