User Manual

96 Xenon XP User Guide
CodeGate
®
When CodeGate is On, the trigger is used to allow decoded data to be transmitted
to the host system. The scanner remains on, scanning and decoding bar codes, but
the bar code data is not transmitted until the trigger is pressed. When CodeGate is
Off, bar code data is transmitted when it is decoded. Default = CodeGate Off Out-of-
Stand.
Streaming Presentation™ Mode
When in Streaming Presentation mode, the scanner’s aimer goes out after a short
time, but the scan illumination remains on all the time to continuously search for
bar codes. Two modes are available, Normal and Enhanced. Normal mode offers
good scan speed and the longest working ranges (depth of field). Enhanced mode
will give you the highest possible scan speed but slightly less range than Normal
mode. Enhanced mode is best used when you require a very fast scan speed and
don’t require a long working range.
When using Preferred Symbology (page 4-104), a lower priority symbol must be
centered on the aiming pattern to be read in Streaming Presentation Mode.
Note: If you are using a cordless charge base, it must have an external power supply
plugged into the aux port for Streaming Presentation to work properly.
* CodeGate Off
Out-of-Stand
CodeGate On
Out-of-Stand
Streaming Presentation
Mode - Normal
Streaming Presentation
Mode - Enhanced