User Manual

106 Xenon XP User Guide
Preferred Symbology Time-out
Once you have enabled Preferred Symbology and entered the high and low priority
symbologies, you must set the time-out period. This is the period of time the scan-
ner will search for a high priority bar code after a low priority bar code has been
encountered. Scan the bar code below, then set the delay (from 1-3,000 millisec-
onds) by scanning digits from the Programming Chart, beginning on page 309,
then Save. Default = 500 ms.
Preferred Symbology Default
Scan the bar code below to set all Preferred Symbology entries to their default val-
ues.
Output Sequence Overview
Output Sequence Editor
This programming selection allows you to program the scanner to output data
(when scanning more than one symbol) in whatever order your application
requires, regardless of the order in which the bar codes are scanned. You can
define up to 15 bar codes in an output sequence.
Note: To make Output Sequence Editor selections, you’ll need to know the code I.D., code
length, and character match(es) your application requires. Use the alphanumeric
symbols from the Programming Chart, beginning on page 309. You must hold the
trigger while reading each bar code in the sequence.
To Add an Output Sequence
An output sequence is created using a string of serial commands that is sent to the
scanner. This string is most easily sent to the scanner using the EZConfig software
tool (see EZConfig-Scanning Introduction on page 237). You can also accomplish
this by scanning alphanumeric bar codes (see the Programming Chart, beginning
on page 309).
Preferred Symbology Time-out
Preferred Symbology Default