User Manual

110 Xenon XP User Guide
SEQSUF99 separator for suffixes, 99 = all symbologies
0D carriage return
0A line feed
The whole command line would look like this:
SEQBLK62999943FF6A999954FF7299994DFFSEQSEP993C3ESEQSUF990D0
A
The data is output as:
<CODE39SMPL>
<TSTMSGCODE128>
<MSGPDF417>
Enter Output Sequence
If you are using bar codes to create your output sequence, scan Enter Output
Sequence to begin scanning your string.
Partial Sequence
If an output sequence operation is terminated before all your output sequence cri-
teria are met, the bar code data acquired to that point is a “partial sequence.” You
can define how partial sequences are output using the same types of command
strings you used to create output sequences.
Partial Sequence Example - Three Symbologies with <> Separators, but with a
Damaged Code
In this example, you are scanning PDF417, Code 128, and Code 39 bar codes, and
you want the scanner to output Code 39 first, Code 128 second, and PDF417 third,
in brackets, as shown below, but the Code 39 bar code has been damaged and can-
not be output.
Enter Output Sequence