Mechanical
Dimensions (LxWxH)
133 mm x 75 mm x 195 mm (5.2” x 2.9” x 7.6”)
Electrical
Input Voltage
4.0 to 5.5 VDC
Host System Interfaces
USB and True RS232
Environmental
Operating Temperature
-30°C to 50°C (-22°F to 122°F)
Storage Temperature
-40°C to 70°C (-40°F to 158°F)
Humidity
0 to 95% relative humidity, non-condensing
Drop
Designed to withstand 50 2m (6.5’) drops to concrete at -30°C
Tumble
5,000 1m (40˝) tumbles
Environmental Sealing
IP65
Light Levels
0 to 100,000 lux (9,290 foot-candles)
ESD
±20Kv air discharge, ±8kV contact discharge
Scan Performance
Scan Pattern
Area Imager
Warranty
3 year factory warranty
Refer to the Honeywell Scanning & Mobility Compliance Center (www.honeywellaidc.com/compliance) to review and download any publicly available
documentation pertaining to the certification of this product in a given country.
Refer to the Honeywell Scanning & Mobility Supported Symbologies Datasheet (www.honeywellaidc.com/symbologies) for a complete listing of all
supported bar code symbologies.