Datasheet
Commercial Thermostats
10 www.honeywell.com/sensing
Table 12. 2455RM/2450CM Series Specifications
Characteristic Parameter
Switch type SPST
Reset type manual
Amperage 15 A resistive at 6,000 cycles (UL); 16 A resistive at 1000 cycles (EU)
Voltage 120 Vac to 250 Vac
Operating temperature range 2455RM: 52 °C to 150 °C [125 °F to 302 °F]
2450CM: 52 °C to 232 °C [125 °F to 450 °F]
Environmental exposure range 2455RM: -20 °C to 177 °C [0 °F to 350 °F]
2450CM: -20 °C to 260 °C [0 °F to 500 °F]
Materials:
Base
Contacts
Terminals
Closure
Brackets
2455RM: phenolic; 2450CM: ceramic
silver alloy
2455RM: unplated brass, plated brass or steel; 2450CM: plated steel
aluminum, brass, or stainless steel
stainless steel
Approvals UL File E36103, CSA File LR21048
Weight 6 g [0.21 oz] (does not include brackets or wire leads)
NOTICE
• 2455RM/2450CM thermostats are intended as a manual reset control. They are not to be used on applications where a limit
thermostat is required unless back-up protection is provided. Units have been tested by UL for 1,000 cycles under load,
5,000 cycles no load, and are not considered as limit devices.
• This range of thermostats has an automatic reset function with manual override function.
• Reset pin operation should not be performed above 70% of set point temperature.
Table 13. 2450CM/2455RM Contact Ratings
Life Cycles 120 Vac 240 Vac
6,000 15 A resistive 10 A resistive
6,000 4.4 FLA 26.4 LRA
125 VA pilot duty
2.2 FLA 13.2 LRA
125 VA pilot duty
Note: Additional contact ratings are available, please consult Honeywell.
Figure 7. 2455RM/2455CM Basic Dimensions
2455RM
2450CM
A Maximum travel of reset button on contact opening
B On contact closing
C Reset button