3200 Linear Imager User’s Guide ™
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
Table of Contents Chapter 1 - Getting Started About This Manual ...................................................... 1-1 Unpacking the Imager ................................................. 1-1 3200 Linear Imager Models ........................................ 1-1 Connecting the Imager with USB ............................... 1-2 USB PC or Macintosh Keyboard ........................... 1-2 Plug and Play ..............................................................
Trigger ......................................................................... 3-1 Automatic Trigger .................................................. 3-2 Reread Delay............................................................... 3-2 Chapter 4 - Data Editing Prefix/Suffix Overview.................................................. 4-1 To Clear One or All Prefixes or Suffixes: ............... 4-3 To Add a Carriage Return Suffix to all Symbologies .........................................................
Code 39....................................................................... 6-4 Code 39 Start/Stop Characters............................. 6-4 Code 39 Check Character..................................... 6-5 Code 39 Message Length ..................................... 6-5 Full ASCII .............................................................. 6-6 Code 39 Code Page.............................................. 6-7 Interleaved 2 of 5 ........................................................
UPC E0 and UPC E1................................................. 6-18 UPC E0 and UPC E1 Expand.............................. 6-18 UPC E0 and UPC E1 Addenda Required ............ 6-18 UPC E0 Check Digit ............................................ 6-19 UPC E0 Number System ..................................... 6-19 UPC E0 Addenda ................................................ 6-19 EAN/JAN 13............................................................... 6-20 EAN/JAN 13 Check Digit .......................
Chapter 9 - Default Chart Resetting the Standard Product Defaults .................... 9-1 Menu Commands ........................................................ 9-1 Chapter 10 - Product Specifications 3200 Linear Imager Product Specifications .............. 10-1 Chapter 11 - Maintenance Repairs ...................................................................... 11-1 Maintenance.............................................................. 11-1 Cleaning the Device ......................................
vi
3200 Imager Identification Item Number, Serial Number and Compliance Information location
1 Getting Started About This Manual This User’s Guide provides installation and programming instructions for the 3200 linear imager. Product specifications, dimensions, warranty, and customer support information are also included. Honeywell barcode imagers are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the barcodes in this guide. An asterisk (*) next to an option indicates the default setting.
Connecting the Imager with USB Note: Honeywell recommends connecting the imager end of the cable first and the host end second. An imager can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the imager and to the computer. 2. The imager beeps. 3. Verify the imager operation by scanning a barcode from the Sample Symbols in the back of this manual.
Plug and Play Plug and Play barcodes provide instant imager set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Connecting the Imager When Powered by Host (Keyboard Wedge) An imager can be connected between the keyboard and PC as a “keyboard wedge,” plugged into the serial port or connected to a portable data terminal. The following is an example of a keyboard wedge connection: 1.
Keyboard Wedge Connection Scanning the barcode below allows operation of the 3200 linear imager as a keyboard wedge interface to an IBM PC AT with a U. S. keyboard. If you programmed the imager for a different terminal interface and you want to change to an IBM PC AT and compatibles keyboard wedge interface, scan the barcode below. Note: The following barcode also programs a carriage return (CR) suffix.
Note: For the imager to work properly, you must have the correct cable for your type of terminal/computer. 3. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. 4. Connect the power supply and plug into an outlet. 5. Turn the terminal/computer power back on. Note: You will not hear a power-up beep because the 3200 linear imager is factory defaulted to a USB connection.
Reading Techniques The imager has a bright red aiming beam that corresponds to its horizontal field of view. The aiming beam should be centered horizontally over the barcode; it will not read if the aiming beam is in any other direction. Good Technique Bad Technique Bad Technique The best focus point for reading most code densities is about 5 inches (12.7 cm) from the unit.
2 Terminal Interfaces Terminal ID If your interface is not a standard PC AT, refer to Terminal ID, beginning on page 2-1 and locate the Terminal ID number for your PC. Scan the Terminal ID barcode below, then scan the numeric barcode(s) from the Programming Chart inside the back cover of this manual to program the imager for your terminal ID. Scan Save to save your selection. For example, an IBM AT terminal has a Terminal ID of 003.
Supported Terminals Terminal RS-232 TTL USB PC Keyboard USB Mac Keyboard Model(s) Terminal ID 000 124 * 125 * Factory default 2-2 3200 User’s Guide
Keyboard Country Scan the appropriate country code below to program the keyboard for your country.
Please refer to Honeywell website (www.honeywellaidc.com) for complete keyboard country support information and applicable interfaces. If you need to program a keyboard for a country other than one listed above, scan the Program Keyboard Country barcode below, then scan the numeric barcode(s) for the appropriate country from the inside back cover, then the Save barcode. Program Keyboard Country Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. Default = Regular.
Control + ASCII Mode On: The imager sends key combinations for ASCII control characters for values 00-1F. Refer to Keyboard Function Relationships, page 7-1 for CTRL+ ASCII Values. Default = Off Control + ASCII Mode On * Control + ASCII Mode Off Numeric Keypad Mode: Sends numeric characters as if entered from a numeric keypad.
RS-232 Baud Rate Baud Rate sends the data from the imager to the terminal at the specified rate. The host terminal must be set for the same baud rate as the imager. Default = 38,400.
RS-232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications which require use of the full ASCII set, select 8 data bits per character. Default = 8. Stop Bits sets the stop bits at 1 or 2. Default = 1. Parity provides a means of checking character bit patterns for validity. Default = None.
RS-232 Handshaking RS-232 handshaking is a set of rules concerning the exchange of data between serially communicating devices. Default = RTS/CTS, XON/XOFF and ACK/ NAK Off.
3 Output Good Read Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = On. * On Off Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the imager emits on a good read. Default = Medium.
Automatic Trigger The imager scans continuously at full power with illumination fully on. Automatic Trigger Reread Delay This sets the time period before the imager can read the same barcode a second time. Setting a reread delay protects against accidental rereads of the same barcode. Longer delays are effective in minimizing accidental rereads at POS (point of sale). Use shorter delays in applications where repetitive barcode scanning is required. Default = Medium.
4 Data Editing Prefix/Suffix Overview When a barcode is scanned, additional information is sent to the host computer along with the barcode data. This group of barcode data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data.
To Add a Prefix or Suffix: Step 1. Scan the Add Prefix or Add Suffix symbol (page 4-3). Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the ) for the symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”. Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Step 4.
To Clear One or All Prefixes or Suffixes: You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted. Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2.
Suffix Selections Add Suffix Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the imager transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page 7-3. When the imager is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable.
Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay barcode below, then scan the number of milliseconds and the SAVE barcode using the Programming Chart inside the back cover of this manual. Prefix Scanned Data 1 2 3 4 Suffix 5 Intercharacter Delay Intercharacter Delay To remove this delay, scan the Intercharacter Delay barcode, then set the number of steps to 0.
Intermessage Delay An intermessage delay of up to 495 milliseconds may be placed between each scan transmission. Scan the Intermessage Delay barcode below, then scan the number of milliseconds and the SAVE barcode using the Programming Chart inside the back cover of this manual. 1st Scan Transmission 2nd Scan Transmission Intermessage Delay Intermessage Delay To remove this delay, scan the Intermessage Delay barcode, then set the number of steps to 0.
5 Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the imager’s output. For example, you can use the Data Format Editor to insert characters at certain points in barcode data as it is scanned. The selections in the following pages are used only if you wish to alter the output. Default Data Format setting = None.
ming Chart inside the back cover of this manual. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) Step 5. Editor Commands Refer to the Format Editor Commands Chart (page 5-2). Scan the symbols that represent the command you want to enter. 94 alphanumeric characters may be entered for each symbology data format. Step 6. Scan Save from the Programming Chart inside the back cover of this manual to save your entries.
Move Commands F5 Move the cursor ahead “nn” characters from current cursor position. Syntax = F5nn (nn stands for the numeric value (00-99) for the number of characters the cursor should be moved ahead.) F7 Move the cursor to the beginning of the data string. Syntax = F7. Miscellaneous Commands FE Compare character in current cursor position to the character “xx.” If characters are equal, increment cursor. If characters are not equal, no format match.
Data Formatter When Data Formatter is turned off, the barcode data is output to the host as read (including prefixes and suffixes). Choose one of the following options. Default = Data Formatter On. * Data Formatter On, but Not Required Data Formatter Off When Data Formatter is required, all input data must conform to an edited format or the imager does not transmit the input data to the host device.
6 Symbologies Introduction This programming section contains the following menu selections. Refer to Chapter 9 for settings and defaults.
EXAMPLE: Decode only those barcodes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those barcodes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the barcodes included in the explanation of the symbology, then scan the digit value of the message length and Save barcodes on the Programming Chart inside the back cover of this manual.
No Check Character indicates that the imager reads and transmits barcode data with or without a check character. When Check Character is set to Validate and Transmit, the imager will only read Codabar barcodes printed with a check character, and will transmit this character at the end of the scanned data. When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar barcodes printed with a check character, but will not transmit the check character with the scanned data.
Code 39 < Default All Code 39 Settings > Code 39 * On Off Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.
Code 39 Check Character No Check Character indicates that the imager reads and transmits barcode data with or without a check character. When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 barcodes printed with a check character, but will not transmit the check character with the scanned data.
Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the barcode symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off.
Code 39 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting.
When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 barcodes printed with a check digit, but will not transmit the check digit with the scanned data. When Check Digit is set to Validate and Transmit, the imager only reads Interleaved 2 of 5 barcodes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit.
Code 93 < Default All Code 93 Settings > Code 93 * On Off Code 93 Message Length Scan the barcodes below to change the message length. Refer to Message Length on page 6-1 for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 93 Code Page Code pages define the mapping of character codes to characters.
Straight 2 of 5 Industrial (three-bar start/stop) Straight 2 of 5 Industrial On * Off Straight 2 of 5 Industrial Message Length Scan the barcodes below to change the message length. Refer to Message Length on page 6-1 for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Straight 2 of 5 IATA On * Off Straight 2 of 5 IATA Message Length Scan the barcodes below to change the message length. Refer to Message Length on page 6-1 for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Matrix 2 of 5 Message Length Scan the barcodes below to change the message length. Refer to Message Length on page 6-1 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 11 Code 11 On * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 barcodes. Default = Two Check Digits.
Code 11 Message Length Scan the barcodes below to change the message length. Refer to Message Length on page 6-1 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 128 Code 128 * On Off ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood information in a uniform manner.
Code 128 Message Length Scan the barcodes below to change the message length. Refer to Message Length on page 6-1 for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 128 Code Page Code pages define the mapping of character codes to characters.
Telepen On * Off Telepen Output Using AIM Telepen Output, the imager reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the imager reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output. * AIM Telepen Output Original Telepen Output Telepen Message Length Scan the barcodes below to change the message length.
UPC A UPC A * On Off UPC A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off UPC A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On.
This selection adds 2 or 5 digits to the end of all scanned UPC A data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off UPC A Addenda Required When Addenda Required is set to on, the imager will only read UPC A barcodes that have addenda. Default = Not Required. Required * Not Required UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code.
UPC E UPC E0 and UPC E1 Most U.P.C. barcodes lead with the 0 number system. For these codes, use the UPC E0 selection. If you need to read codes that lead with the 1 number system, use the UPC E1 selection. Default = On (UPC E0) and Off (UPC E1). * UPC E0 On UPC E0 Off UPC E1 On * UPC E1 Off UPC E0 and UPC E1 Expand UPC E Expand expands the UPC E code to the 12 digit, UPC A format. Default = Off.
UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off UPC E0 Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. * On Off UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data. Default = Off for both 2 Digit and 5 Digit Addenda.
EAN/JAN 13 * On Off EAN/JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off EAN/JAN 13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 13 data. Default = Off for both 2 Digit and 5 Digit Addenda.
EAN/JAN 13 Addenda Separator When this feature is on, there is a space between the data from the barcode and the data from the addenda. When turned off, there is no space. Default = On. * On Off Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code on page 6-17. ISBN Translate This selection causes EAN-13 Bookland symbols to be translated into their equivalent ISBN number format. Default = Off.
EAN/JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off EAN/JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 8 data. Default = Off for both 2 Digit and 5 Digit Addenda.
EAN/JAN 8 Addenda Separator When this feature is on, there is a space between the data from the barcode and the data from the addenda. When turned off, there is no space. Default = On. * On Off MSI MSI On * Off MSI Check Character Different types of check characters are used with MSI barcodes. You can program the imager to read MSI barcodes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit.
MSI Message Length Scan the barcodes below to change the message length. Refer to Message Length on page 6-1 for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length Plessey Code Plessey Code On * Off Plessey Message Length Scan the barcodes below to change the message length. Refer to Message Length on page 6-1 for additional information.
RSS-14 * On Off RSS Limited < Default All RSS Limited Settings > RSS Limited * On Off RSS Expanded < Default All RSS Expanded Settings > 3200 User’s Guide 6 - 25
RSS Expanded * On Off RSS Expanded Message Length Scan the barcodes below to change the message length. Refer to Message Length on page 6-1 for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74. Minimum Message Length Maximum Message Length EAN•UCC Emulation The imager can automatically format the output from any EAN•UCC data carrier to emulate what would be encoded in an equivalent UCC/EAN-128 or RSS+Composite symbol.
China Post Code On * Off China Post Message Length Scan the barcodes below to change the message length. Refer to Message Length on page 6-1 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80.
6 - 28 3200 User’s Guide
7 Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the imager. Refer to page 2-5 enable Control + ASCII mode.
The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of these five characters for different countries. Country Codes United States [ \ ] 6 - Belgium [ < ] 6 - Scandinavia 8 < 9 6 - France ^ 8 $ 6 = Germany à + 6 - Italy \ + 6 - Switzerland < ..
Supported Interface Keys ASCII NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US HEX 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F IBM AT/XT and PS/2 Compatibles, WYSE PC/AT Supported Keys Reserved Enter (KP) Cap Lock ALT make ALT break CTRL make CTRL break CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
7-4 3200 User’s Guide
8 Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, included in the , page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D. prefix for all symbologies. This is a temporary setting that will be removed when the unit is power cycled. Add Code I.D.
8-2 3200 User’s Guide
9 Default Chart Resetting the Standard Product Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings barcode below. Standard Product Default Settings The chart on the following pages lists the factory default settings for each of the menu commands (indicated by an asterisk (*) on the programming pages).
Selection Keyboard Modifiers Setting * Indicates default Page *Control + ASCII Off 2-5 Control + ASCII On 2-5 *Numeric Keypad Off 2-5 Numeric Keypad On 2-5 *Auto Direct Conn. Off 2-5 Auto Direct Conn.
Selection RS-232 Handshaking Setting * Indicates default Page *RTS/CTS Off 2-8 RTS/CTS On 2-8 *XON/XOFF Off 2-8 XON/XOFF On 2-8 *ACK/NAK Off 2-8 ACK/NAK On 2-8 Off 3-1 *On 3-1 Off 3-1 Low 3-1 Medium 3-1 *High 3-1 Low (1600) (min 400Hz) 3-1 *Medium (2550) 3-1 High (4200) (max 9000Hz) 3-1 *Manual/Serial Trigger 3-1 Automatic Trigger 3-2 Short (500 ms) 3-2 *Medium (750 ms) 3-2 Long (1000 ms) 3-2 Extra Long (2000 ms) 3-2 Output Selections Beeper - Good Read Beeper Vo
Selection Function Code Transmit Setting * Indicates default Page *Enable 4-4 Disable 4-4 Intercharacter Delay 4-5 Interfunction Delay 4-5 Intermessage Delay 4-6 Data Formatter Selections Data Format Editor *Default Data Format (None) 5-3 Enter Data Format 5-3 Clear One Data Format 5-3 Clear All Data Formats 5-3 Off 5-4 *On, but Not Required 5-4 On, Required 5-4 All Symbologies All Symbologies Off 6-1 All Symbologies On 6-1 Codabar Default All Codabar Settings 6-2 Codabar
Selection Setting * Indicates default Page Code 39 Start/Stop Char. *Don’t Transmit 6-4 Transmit 6-4 Code 39 Check Char. *No Check Char. 6-5 Validate, But Don’t Transmit 6-5 Validate, and Transmit 6-5 Code 39 Message Length Minimum (0 - 48) *0 6-5 Maximum (0 - 48) *48 6-5 Code 32 Pharmaceutical (PARAF) *Off 6-5 On 6-5 Code 39 Full ASCII *Off 6-6 On 6-6 Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings 6-7 Interleaved 2 of 5 Off 6-7 *On 6-7 *No Check Char.
Selection Setting * Indicates default Page Straight 2 of 5 Industrial Message Length Minimum (1 - 48) *4 6-10 Maximum (1 - 48) *48 6-10 Straight 2 of 5 IATA Default All Straight 2 of 5 IATA Settings 6-11 Straight 2 of 5 IATA *Off 6-11 On 6-11 Straight 2 of 5 IATA Message Length Minimum (1 - 48) *4 6-11 Maximum (1 - 48) *48 6-11 Matrix 2 of 5 Default All Matrix 2 of 5 Settings 6-11 Matrix 2 of 5 *Off 6-11 On 6-11 Matrix 2 of 5 Message Length Minimum (1 - 80) *4 6-12 Maximum (1
Selection Setting * Indicates default Page Code 128 Function Code Transmit *Off 6-14 On 6-14 ISBT Concatenation *Off 6-13 On 6-13 Telepen Default All Telepen Settings 6-15 Telepen *Off 6-15 On 6-15 *AIM Telepen Output 6-15 Telepen Output Original Telepen Output 6-15 Telepen Message Length Minimum (1 - 60) *1 6-15 Maximum (1 - 60) *60 6-15 UPC A Default All UPC A Settings 6-16 UPC A Off 6-16 *On 6-16 UPC A Check Digit Off 6-16 *On 6-16 UPC A Number System Off 6-1
Selection UPC E Expand Setting * Indicates default Page *Off 6-18 On 6-18 Off 6-19 *On 6-19 UPC E Number System Off 6-19 *On 6-19 UPC E 2 Digit Addenda *Off 6-19 On 6-19 UPC E 5 Digit Addenda *Off 6-19 On 6-19 UPC E Addenda Required *Not Required 6-18 Required 6-18 EAN/JAN 13 Default All EAN/ JAN 13 Settings 6-20 EAN/JAN 13 Off 6-20 *On 6-20 EAN/JAN 13 Check Digit Off 6-20 *On 6-20 EAN/JAN 13 2 Digit Addenda *Off 6-20 On 6-20 EAN/JAN 13 5 Digit Addenda *Off
Selection Setting * Indicates default Page EAN/JAN 8 Check Digit Off 6-22 *On 6-21 EAN/JAN 8 2 Digit Addenda *Off 6-22 On 6-22 EAN/JAN 8 5 Digit Addenda *Off 6-22 On 6-22 EAN/JAN 8 Addenda Required *Not Required 6-22 Required 6-22 EAN/JAN 8 Addenda Separator Off 6-23 *On 6-23 Coupon Code Off 6-23 *On 6-17 MSI Default All MSI Settings 6-23 MSI *Off 6-23 On 6-23 *Validate Type 10, but Don’t Transmit 6-23 Validate Type 10 and Transmit 6-23 Minimum (4 - 48) *4 6-24
Selection RSS Limited Setting * Indicates default Page Off 6-25 *On 6-25 RSS Expanded Default All RSS-14 Expanded Settings 6-26 RSS Expanded Off 6-26 *On 6-26 RSS Expanded Msg.
10 Product Specifications 3200 Linear Imager Product Specifications Parameter Specification Dimensions (Typical): Height 3.7 inches (9.4 cm) Length 6 inches (15.2 cm) Width 2.7 inches (6.9 cm) Weight 5.1 ounces (145 g) Light Source 630 nm ± 30mn visible red LED Scan Rate 200+ scans per second in most usages Skew Angle ±55 degrees Pitch Angle ±55 degrees Scan Contrast 30% minimum Voltage Requirements 5VDC ±5% at imager Current Draw (Max): 3200 @ 4.75 - 5.
10 - 2 2 Cord shield 3 Tied to supply power 4 Supply ground 5 Terminal clock 6 Terminal data 7 Supply power input (Refer to tables on page 10-1) 8 Keyboard data 9 Keyboard clock 10 1 connects to the imager handle 10 Pin RJ41 Modular Plug Standard Cable Pinouts Keyboard Wedge 3200 User’s Guide
3200 User’s Guide 2 Cord shield 3 Prog 1 (Tied to supply power for primary cable) 4 Supply ground 5 Receive data - Serial data to imager 6 Transmit data - Serial data from imager 7 Supply power input (Refer to tables on page 10-1) 8 Request to send data 9 Clear to send data 10 1 connects to the imager handle 10 Pin RJ41 Modular Plug Standard Cable Pinouts Serial Output 10 - 3
10 - 4 10 Pin Modular Plug connects to the imager handle 1 2 Data + 3 Tied to supply power 4 Supply ground 5 6 7 5 volt supply power input 8 9 10 Data - Standard Cable Pinouts USB 3200 User’s Guide
11 Maintenance Repairs Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center. Please see Customer Support on page 12-1 for further information. Maintenance The 3200 linear imager provides reliable and efficient operation with a minimum of care.
Replacing the Interface Cable The standard interface cable is attached to the scanner with an 10-pin modular connector. When properly seated, the connector is held in the 3200 linear imager’s handle by a flexible retention tab. The interface cable is designed to be field replaceable. • Order replacement cables from an authorized distributor. • When ordering a replacement cable, specify either the 6 ft. USB cable (p/n AMCBC000800DAR0) or the 6 ft. keyboard wedge cable (p/n AMCBC000900DAR0).
Is the scanner having trouble reading your symbols? If the scanner isn’t reading symbols well, check that the symbols: • Aren’t smeared, rough, scratched, or exhibiting voids. • Aren’t coated with frost or water droplets on the surface. • Are enabled in the scanner or in the decoder to which the scanner connects. Is the barcode displayed but not entered? The barcode is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or the Tab key, for example).
11 - 4 3200 User’s Guide
12 Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 E-mail: hsmnasupport@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (21) 3535-9100 Fax: +55 (21) 3535-9105 E-mail: brsuporte@honeywell.
Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product. North America Telephone: (800) 782-4263 E-mail: hsmnaservice@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 Fax: (239) 263-9689 E-mail: laservice@honeywell.
Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.honeywellaidc.com. Limited Warranty Honeywell International Inc. ("HII") warrants its products to be free from defects in materials and workmanship and to conform to HHI’s published specifications applicable to the products purchased at the time of shipment.
BILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HII MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. SOME STATES, PROVINCES, OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
A Appendix A Symbology Chart Symbology Code AIM ID ID Hex ID Symbology Code AIM ID ID Hex ID China Post Q ]X0 51 IATA 2 of 5 f ]Rm 66 Codabar a ]Fm 61 Interleaved 2 of 5 e ]lm 65 Codablock F q ]Om 71 Korea Post ? ]X0 3F Code 2 of 5 f ]Rm 66 Matrix 2 of 5 m ]X0 6D Code 11 h ]Hm 68 MSI g ]Mm 67 Code 16K o ]Km 6F No Read 9C Code 39 b ]Am 62 Plessey Code n ]P0 6E Code 32 Pharmaceutical (PARAF) < ]X0 3C PosiCode W ]pm 57 l ]Tm 6C Reduced Spa
ASCII Conversion Chart (Code Page 1252) Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings.
Dec Hex Char Dec Hex Char Dec Hex 160 A0 192 C0 À 224 E0 à 161 A1 ¡ 193 C1 Á 225 E1 á 162 A2 ¢ 194 C2 Â 226 E2 â ƒ 163 A3 £ 195 C3 Ã 227 E3 ã 84 „ 164 A4 ¤ 196 C4 Ä 228 E4 ä 85 … 165 A5 ¥ 197 C5 Å 229 E5 å 134 86 † 166 A6 ¦ 198 C6 Æ 230 E6 æ 135 87 ‡ 167 A7 § 199 C7 Ç 231 E7 ç 136 88 ˆ 168 A8 ¨ 200 C8 È 232 E8 è 137 89 ‰ 169 A9 © 201 C9 É 233 E9 é 138 8A Š 170 AA ª 202 CA Ê 234 EA ê 1
Code Page Mapping of Printed barcodes Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, select the code page with which the barcodes were created. The data characters should then appear properly. Note: The Code Page option is available for Code 39, Code 93, and Code 128.
Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 1234567890 Code 128 Code 128 EAN 13 EAN 8 9 780330 290951 654 3210 5 UPC-E 0 456123 8
Sample Symbols Code 39 BC321 Code 93 123456-9$ Matrix 2 of 5 6543210 Codabar A13579B Straight 2 of 5 Industrial 123456 RSS-14 (01)00123456789012
Programming Chart 0 1 2 3 4 5 6 7 8 9 A B C D E F Discard Note: Save If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save.