® ScanPal 2 Portable Data Terminal User manual Printed August 2001
ScanPal 2 The content of this manual is the property of Metrologic Instruments Inc. The information contained in this manual has been carefully checked and is considered to be accurate. Metrologic Instruments Inc. accepts no responsibility regarding any inaccuracies in this document.
Table of Contents 1. Introduction ........................................................................................................ 2 2. General characteristics...................................................................................... 3 2.1. 2.2. 2.3. 2.4. 2.5. 2.6. 2.7. 2.8. 2.9. 2.10. 2.11. 2.12. Electrical characteristics ...................................................................................... 3 Environment ...............................................................
1. Introduction The ScanPall2 is a high performance, light-weight and compact portable terminal, designed for daily intensive use. It is powered by two ‘AAA’ replaceable batteries or one Ni-MH rechargeable battery and is equipped with a comprehensive set of development tools, including a Windows based application generator, a "BASIC" compiler and a "C" compiler.
2. General characteristics The basic characteristics of the ScanPall2 are as follows: Electrical characteristics • Main battery................................ two AAA replaceable batteries or one Ni-MH rechargeable battery • Backup battery............................ 3.0 V, 7.0 mAh rechargeable lithium battery, for the static random access memory (SRAM) and the calendar • Stand-alone operation ................
• Dual clock with low-speed mode capability for saving the batteries (for further information on the Speed setting, refer to section 5.
Memory • Program...................................... 1-MB Flash-ROM, flash memory used for saving the program, character sets, constants, etc. • Data............................................ 1 MB SRAM, static random access memory Scanner The ScanPall2 is equipped with a CCD scanner. The scanners characteristics are as follows: ScanPal 2C (CCD) • Minimum bar width...................... 0.102 mm (4 mil) • Depth of field .............................. 30 mm – 160 mm (1.2” – 6.3 “) for 0.
Indicator • Buzzer ........................................ audible indicator, programmable from 1 KHz to 4 KHz, low-power transducer type • LED ............................................ dual-colour (green and red) programmable LED Communication Three types of communication are possible: standard RS232, infrared and screen/keyboard. • RS232 ........................................ transmission speed up to 115,200 bps • Infrared ....................................... standard 1.
For the references and descriptions, refer to section 7. 3. Hardware configuration Front, back and side view 63mm IrDA 33.
4. Software organization The ScanPall2 software system consists of three modules: • The Kernel module • The System (Operating System) module • The Program module Kernel Module The Kernel module forms the heart of the system. It is extremely secure and always protected by the system. Only a failure of the flash memory or incorrect switching off of the power supply, during system restart after a kernel update, can destroy the kernel.
For further information, refer to section 5.3.
Program Module The Program module operates on top of the System module. The user programs are downloaded into this module. The user program, downloaded into the Program module, is started automatically when the ScanPall2 is powered up. The user program pre-loaded into the Program module of the ScanPall2 is the application interpreter, making it possible to run an application created with the application generator.
For further information on the development tools, contact one of the Metrologic offices: Metrologic Instruments, Inc – Corporate Headquarters Tel: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com Metrologic Instruments GmbH – European, Middle East, & African Headquarters Tel: +49(0) 89 890 190 Fax: +49(0) 89 890 19 200 Email: info@europe.metrologic.com Metrologic do Brasil Ltda. – Brazil only Tel: 5511-5505-2396 Fax: 5511-5507-2301 Email: info@br.metrologic.
5. Operations Before any operation, it is advisable to make sure that the replaceable batteries are new, or that the rechargeable battery is correctly charged. Operations at the keypad The ScanPall2 keypad consists of 20 rubber keys and one key for triggering the scanner. The functions of the special keys are as follows: Enter Confirms an entry on the keypad. Back Space BS Deletes the characters situated to the left of the cursor. Space SP Inserts the space character. X Up Moves the cursor upwards.
FN Function This key cannot be used on its own, but in combination with a numeric key (1 to 9), in order to obtain a specific function, depending on the program loaded. 1 STU FN For example, pressing simultaneously on the keys activates the function #1 (up to 9 functions). X Pressing simultaneously on the FN and , or , keys makes it possible to adjust the screen contrast. and FN and Y Pressing simultaneously on the FN and keys makes it possible to activate or de-activate the screen backlighting.
Program Mode This is the default operating mode when the ScanPall2 is powered up. It depends on the user program loaded into the Program module. The application interpreter and its inventory application, loaded by default, displays the following main menu: 1.Collect data 2.Upload data 3.Utilities JUN 16, 13:30 (R) 00000 The counter, located in the bottom right-hand corner of the screen, displays the number of records collected. 1.
2. Upload data Uploads the data collected, via the selected upload port. The letter displayed on the screen, at the right of the Upload Data line, indicates the selected upload port: RS232 (R) , IR (T), IrDA (I) or Wedge (K). On the PC (under Windows), to receive the data and create a text file, use the application generator, 232_Read.EXE or IR_Read.EXE. For further information, refer to the application generator user manual. 3.
- Data Deletion Defines whether, after an upload, the data is deleted Manually, with a request for confirmation, or Automatically, with no request for confirmation. Default value: Manually. - Record Prompting Activates (Yes) or de-activates (No) the display of the record number, after confirmation of an entry. Default value: Yes. - View Settings Displays the various settings. • Browse Data Displays the data collected. The a loop, of all the data collected.
Defines the date and time.
• Download Program Downloads an application (*.ATX) created with the application generator into the ScanPall2 Portable Terminal, via the selected download port. The letter displayed on the screen, at the right of the Download Program line, indicates the selected download port: RS232 (R), IR (T) or IrDA (I). On the PC (under Windows), use the application generator or ATX_Load.EXE. For further information, refer to the application generator user manual.
System Mode Turn off the ScanPall2, and then simultaneously press the 7 ABC , 9 GHI and keys to enter System mode. System mode offers the following operations: System Menu 1 Memory 2 Setting 3 Reader 4 Battery 5 Test 6 Download 7 Version 1. Memory • Size Information Displays the size of the data memory (SRAM) and the size of the program memory (Flash ROM), in kilobytes. • Initialize Initializes the data memory (SRAM). Note: after an initialization, the data contained in the memory is deleted.
• Speed Defines the CPU operating speed. Five speeds are available: Speed Consumption Full ......................... 39 mA 1/2.......................... 22 mA 1/4.......................... 12 mA 1/8............................ 7 mA 1/16.......................... 5 mA The consumptions are given for normal operation, with no scanner reading or data transmission. If the full-speed mode is not necessary, choose the lowest speed, in order to save the batteries. Default value: Full speed.
3. Reader Tests the scanner read performance and displays the bar code read, its length, and a letter identifying the code type (symbology). The symbologies enabled by default are as follows: Symbology Identifier Code 39 ..................................... A Industrial 2/5 .............................D Interleaved 2/5 ........................... E Codabar .....................................G Code 93 .....................................H Code 128 ....................................
Tests the LCD screen and the dual-colour LED. Press the key to start or stop the test.
• KBD Tests the keypad keys. Pressing a key displays its value on the screen. The FN must be used in combination with a numeric key (1 to 9). Press the ESC function key key to stop the test. 6. Download • RS232 Downloads a user program (*.SHX) into the ScanPall2, via the RS232 port (cable or download cradle). On the PC (under Windows), use DownLoad.EXE. The speed can go up to 115,200 bps. • IR (High-speed infrared) Downloads a user program (*.
Kernel Mode Turn off the ScanPall2, and then simultaneously press the 7 ABC , 9 GHI and keys to enter System mode; next turn off the ScanPall2, and then STU 1 7 ABC simultaneously press the , and keys to enter Kernel mode. Kernel mode offers the following operations: Kernel Menu 1 Program Download 2 Update Kernel 3 Test & Calibrate 4 Version 1. Program Download Downloads a user program (*.SHX) into the ScanPall2. The download procedure is identical to that described in System mode (refer to section 5.
4. Version Displays the following information: Hardware version number .........................(H/W) Serial number............................................ (S/N) Manufacturing date ...................................(M/D) Kernel version number ..............................
Overview R232_Read.EXE To be defined by programming DLookup.EXE or or directly from AG_SP2.exe Ir_Read.EXE or directly from AG_SP2.exe To be defined by programming Data Data Data Application "BASIC" program "C" program File Ý.ATX Application created with the application generator AG_SP2.EXE ATX_Load.EXE Program Module or directly from AG_SP2.EXE ScanPal 2 off Application generator File USP2Ý.SHX Application interpreter (1) DownLoad.EXE or IrLoad.
6. Troubleshooting guide • The ScanPall2 doesn’t come on after the key has been pressed. Change the batteries or recharge the battery. • The ScanPall2 doesn’t come on after the batteries have been changed or the battery recharged. Check that the replaceable batteries are correctly installed in their compartment and that the compartment (or the rechargeable battery) is properly engaged in the terminal. If the problem persists, contact Technical Support.
If the problem persists, contact Technical Support.
The scanner doesn’t work. Check that the symbologies of the codes read are enabled. Check whether the battery icon, indicating the charge state, is empty. If this is the case, change the replaceable batteries or recharge the battery. If the problem persists, contact Technical Support.
7.