Home Security System User Manual
Table Of Contents
- ONYX®FirstVision™
- Fire Alarm System Limitations
- Installation Precautions
- FCC Warning
- Section 1 Introduction
- Section 2 FirstVision Installation Instructions
- Section 3 Enabling FirstVision to Monitor Your Building
- 3.1 Process Overview
- 3.2 Make Connections to FirstVision
- 3.3 Turn on Power to FirstVision
- 3.4 Set the FirstVision Clock and Time Zone
- 3.5 Establish Communication Between Your LAN and FirstVision
- 3.6 Establish Gateway Communication
- 3.7 Copy Your Exported Building Design to FirstVision
- 3.8 Display Your Building Design on FirstVision
- 3.9 Test Your Building Design on FirstVision
- 3.10 Touch Screen Calibration
- Section 4 Operating Basics of FirstVision
- 4.1 Normal Operation (No Events Being Reported)
- Figure 4.1 FirstVision Display Example: No Alarms
- Figure 4.2 FirstVision Display Example: Floor Number Button
- Figure 4.3 FirstVision Display Example: Building Information
- Figure 4.4 FirstVision Display Example: Zoomed Floor Plan
- Figure 4.5 FirstVision Display Example: Moving Through a Zoomed Floor Plan
- Figure 4.6 FirstVision Display Example: HAZMAT Information
- 4.2 Investigating Gateway Disconnection
- 4.3 Operation When a Fire Alarm is Received
- 4.4 Operation After a Fire Alarm Has Been Cleared
- 4.5 Accessing the Log File
- 4.1 Normal Operation (No Events Being Reported)
- Section 5 The Development of FirstVision
- 5.1 The Current Situation for a Firefighter
- 5.2 The Technology of FirstVision
- 5.3 Expected Firefighter Interaction with the FirstVision
- 5.3.1 Example Emergency Situations
- Figure 5.1 Fire Scene Scenario Floor Plan Information
- Figure 5.2 Fire Scene Scenario Roof Plan Information
- Figure 5.3 Fire Scene Scenario HAZMAT Information
- Figure 5.4 Fire Scene Scenario Building Information
- Figure 5.5 Example Building Site Plan Information
- Figure 5.6 Example HAZMAT Information
- Figure 5.7 Example Contact Information
- 5.3.1 Example Emergency Situations
- Index
![](/manual/honeywell/53034/home-security-system-user-manual/images/img-6.png)
Introduction FIRSTVISION Specifications
4 FIRSTVISION™ Installation and Operation Manual - P/N: 53034:Rev: A2 10/29/07
Table 1.2 FIRSTVISION LCD Specifications
Part Number FIRSTVISION-LCD
Product 17" Interactive Graphic Display
Display:
Size 17"
Resolution 1280 x 1024, 75 Hz, 32 Bit colors
Surface acoustic wave touchscreen USB TS controller
CPU:
Digital I/O (1) DO – Lock control, (3) DO – Brightness control
ACPI Compliant Not required
Processor Low Power VIA Fanless CPU
Speed 733MHz
Form factor Embedded
Slots NONE REQUIRED
Video Integral
Serial ports (1) RS-232
USB ports TWO
System RAM 512 MB
LAN One 10/100 Base-T interface
Peripherals:
Compact Flash Disk 2GB
Connectors (1) DB9 COM1
(1) DIN - KYBD
(1) RJ-45 10/100BT
(2) USB Ports on the front panel
(2) Speakers (2 Watts)
Operating System Windows® XP® Embedded
Other:
Motherboard Lithium Battery Battery is not field replaceable. Contact Technical Services for information.
DC to DC Converter Fuse Fuse is only replaceable by authorized personnel. Contact Technical Services for
information.
Fuse:10A, 250V, SLO BLO, 5x20mm.