METROLOGIC INSTRUMENTS, INC.
Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this document are hereby acknowledged as trademarks, registered or otherwise, of Metrologic Instruments, Inc.
TABLE OF CONTENTS Introduction Product Overview ............................................................................................. 1 Scanner and Accessories................................................................................. 2 Scanner Components....................................................................................... 4 Caution and Serial Number Labels................................................................... 5 Cable Removal......................................
TABLE OF CONTENTS Troubleshooting Guide ....................................................................................... 27 Design Specifications ......................................................................................... 31 Applications and Protocols ................................................................................. 33 Default Settings - Communication Parameters................................................... 34 Upgrading the Flash ROM Firmware .......................
INTRODUCTION ® The QuantumT is a hands-free, omnidirectional bar code scanner with optional single-line scanning capabilities. It utilizes the powerful Metrologic QuantumE ® scan engine to provide an outstanding scan performance on all standard 1D barcode symbologies, including RSS. This fully enclosed scanner includes large easily visible LEDs and a rugged protective boot with an adjustable stand. The QuantumT can be mounted to a countertop, wall or be left free standing for handheld scanning.
INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description MS3580 QuantumT Omni \ Single-Line Scanner 00-02026 QuantumT Omni \ Single-Line Scanner Installation and User’s Guide * 00-02407 MetroSelect® Configuration Guide * * Guides also available for download at www.metrologic.com. OPTIONAL ACCESSORIES Part No. Description AC to DC Power Transformer - Regulated 5.2VDC @ 1 A output.
INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 54-54002x-3 Keyboard Wedge PowerLink Cable 2.1 m (7 ft.) straight cord, short strain relief 54-54020x-3 Stand Alone Keyboard PowerLink Cable 2.1 m (7 ft.) straight cord, short strain relief 54-54213x-N-3 ™ USB Full Speed Cable, Locking Plus-Power Type A 3 m (10 ft.) straight cord, short strain relief USB Full Speed Cable, Locking Plus-Power™ Type A 5 m (17 ft.
INTRODUCTION Scanner Components Figure 1. Scanner Components ITEM NO. DESCRIPTION 1 Red Output Window (Laser Aperture) 2 Pin Hole for Cable Release 3 10-Pin RJ45, Female Socket 4 Speaker 5 Blue and White LED Indicators 6 Button Protective Boot and Stand Connection 7 Never remove the protective boot from the MS3580. Removing the protective boot will expose electrical components of the scanner that are highly susceptible to electrostatic discharge (ESD).
INTRODUCTION Caution and Serial Number Labels Figure 2. Labeling Example Caution To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet applicable performance requirements for a limited power source. Cable Removal 1.
INTRODUCTION Mounting Specifications and Stand Assembly Pedestal Stand Figure 4. Pedestal Stand Assembly Optional Flex Stand Figure 5. Assembly Components for Optional Flex Stand Item 1 2 3 4 5 Description MS3580, QuantumT Pivot Cylinder Bearing Plate Pole Mount Adapter Flexible Shaft Cover* Qty. 1 1 1 1 1 Item 6 7 8 9 10 Description Flexible Shaft* Base Plate Cover #8 x 1.
INTRODUCTION Mounting Specifications and Stand Assembly Optional Flex Stand Figure 6. Mounting Hole Detail for the Flex Stand Base Plate (Optional) Figure 7.
INSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS3580. 3. Connect the 9-pin female end of the PowerLink cable to the host device. 4. Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.
INSTALLATION IBM 46xx or OCIA 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS3580. 3. Connect the other end of the MVC cable to the host device. 4. Turn on the host device. Figure 9. When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously emit a beep and flash the white LED. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC.
INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS3580. 3. Disconnect the keyboard from the host device. 4. Connect the “Y” end of the PowerLink cable to the keyboard and the keyboard port on the host PC. If necessary use the male/female adapter cable supplied with the scanner for proper connections. 5. Plug the external power supply into the power jack on the PowerLink cable.
INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS3580. 3. Connect the other end of the PowerLink cable to the keyboard port on the host device. 4. Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible. 5.
INSTALLATION Full Speed or Low Speed USB 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the MS3580. 3. Plug the other end of the USB interface cable into the host device’s USB port. 4. Turn on the host device. Figure 12. When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously emit a beep and flash the white LED. As a default, the MS3580-38 leaves the factory with USB Keyboard Emulation Mode enabled.
SCANNER OPERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable scan pattern modes available with the MS3580. • The primary scan pattern mode is the default scan pattern active when the scanner starts. • The secondary scan pattern mode is activated by pressing the button located on the side of the scanner. This mode is also referred to as the button mode.
SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED For illustration purposes the unit’s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 5 second button click timeout configured. 14 1. The primary scan pattern is active when the scanner starts. 2. To activate the secondary scan pattern, press and release the button. 3.
SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED For illustration purposes the unit’s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 5 second button click timeout configured. 1. The primary scan pattern is active when the scanner starts. 2. To activate the secondary scan pattern, press and release the button. 3.
SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE ENABLED For illustration purposes the unit’s* primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 5 second button click timeout configured. 16 1. The primary scan pattern is active when the scanner starts. 2. To activate the secondary scan pattern, press and hold the button. 3.
SCANNER OPERATION Configurable Button Functions 5. To scan and transmit additional bar codes, repeat steps 2 through 4. 6. The primary scan pattern will automatically reactivate after the button is released and no bar code is present in the scan field.
SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the unit’s* primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 5 second button click timeout configured. 18 1. The primary scan pattern is active when the scanner starts. 2. To activate the secondary scan pattern, press and hold the button. 3.
SCANNER OPERATION Audible Indicators When the MS3580 is in operation, it provides audible feedback to indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). For instructions on how to change the tone of the beeper, refer to the MetroSelect Configuration Guide (00-02407).
SCANNER OPERATION Visual Indicators The QuantumT is equipped with a blue and white LED that indicates the scanner’s state and the status of the current scan when the unit is in operation. Figure 13. Speaker Location and LED Location No LEDs The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. They are also not illuminated when the laser is turned off for any reason. Steady Blue When the laser is active, the blue LED is illuminated.
SCANNER OPERATION Failure Mode Indicators Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsystem failure. Return the unit to an authorized service center for repair. Flashing Blue and White and Two Razzberry Tones This indicates that the scanner has experienced a motor failure. Return the unit to an authorized service center for repair.
SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. † Figure 14. MS3580 Normal Depth of Field * All specifications are subject to change without notice. † MS3580 shown with pedestal stand.
SCANNER OPERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. † Figure 15. MS3580 Reduced Depth of Field * All specifications are subject to change without notice. † MS3580 shown with pedestal stand.
SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15 .19 .25 .33 .66 mils 5.2 5.7 7.5 10 13 26 Figure 16. Normal Scan Zone by Bar Code Element Width * All specifications are subject to change without notice.
SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15 .19 .25 .33 .66 mils 5.2 5.7 7.5 10 13 26 Figure 17. Reduced Scan Zone by Bar Code Element Width * All specifications are subject to change without notice.
SCANNER OPERATION IR Activation Range* QuantumT‘s default power save mode† is Laser OFF. This power save mode turns the laser off after a configured period of non-use. Any movement detected by the IR in the activation area will cause the scanner to exit power save mode. The laser will automatically turn back on preparing the scanner for bar code recognition, decoding and transmission. Figure 18. Normal IR Activation Range * All specifications are subject to change without notice.
TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 46. Symptoms Possible Cause(s) Solution All Interfaces The unit has no LEDs, beeper or motor spin. No power is being supplied to the scanner. Check the transformer, outlet and power strip. Make sure the cable is plugged into the scanner. The unit has no LEDs and / or beeper.
TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution The unit scans a bar code, but locks up after the first scan (the white LED stays on). The scanner is configured to support some form of host handshaking but is not receiving the signal. If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly. The unit scans but the data transmitted to the host is incorrect.
TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces During power up the unit beeps 3 times. There is a non-volatile RAM failure. Contact a Metrologic service representative. During power up the unit razzes continuously. There is a RAM or ROM failure. Contact a Metrologic service representative. During power up the unit razzes once and the blue LED flashes. There is a VLD failure. Contact a Metrologic service representative.
TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The host is The scanner and host receiving data may not be configured but the data does for the same interface. not look correct. Characters are being dropped. The intercharacter delay needs to be added to the transmitted output. Check that the scanner and the host are configured for the same interface. Add some intercharacter delay to the transmitted output by using the MetroSelect Configuration Guide (MLPN 00-02407).
DESIGN SPECIFICATIONS MS3580 Operational Light Source: Laser Power: Normal Depth of Field: Reduced Depth of Field: Visible Laser Diode (VLD) @ 650 nm 1.1 mW 19 mm - 273 mm (.75"- 10.75") 19 mm - 146 mm (.75"- 5.75") 0.33 mm (13 mil) bar code Omni Scan Scan Speed: No. of Scan Lines: 1650 scan lines per second 20 Single-Line Scan Speed: No. of Scan Lines: 80 scan lines per second 1 Raster Scan Speed: No. of Scan Lines: Motor Speed: Min Bar Width: 320 scan lines per second 4 5000 RPM 0.127 mm (5.
DESIGN SPECIFICATIONS MS3580 Mechanical Width: 63 mm (2.48") Depth: 50 mm (1.97") Height: 68 mm (2.68") Weight: 6 oz (170 g) Electrical Voltage Supply: Operating Power: Standby Power: 5VDC ± 0.25V 1.375 W 1.0 W Operating Current: 275 mA typical at 5VDC Standby Current: 230 mA typical at 5VDC DC Transformers: Class II; 5.
APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol.
DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled. Every interface does not support every parameter.
DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* PARAMETER Expanded ID “]e0” DEFAULT OCIA USB OR RS232 TTL LIGHT IBM PEN 46XX KBW LASER EMULATION * RSS Limited Enable RSS Limited ID “]e0” * RSS Limited App ID “01” * RSS Limited Check Digit * Bars High as Code 39 * Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS DTS/NIXDORF * NCR F NCR S Poll Light Pen Source Beeper Tone Normal Beep/Transmit Sequence Before Transmit Communication Timeout None Razzberr
DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* PARAMETER Transmit UPC-A Check Digit DEFAULT * Transmit UPC-E Check Digit Expand UPC-E Convert UPC-A to EAN-13 Transmit Lead Zero on UPC-E Convert EAN-8 to EAN-13 Transmit UPC-A Number System * Transmit UPC-A Manufacturer ID# * Transmit UPC-A Item ID# * Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 43 Check Digit on Code 39 Transmit Code 39 Stop/Start Characters Transmit Mod 10/ITF Transmit MSI-Plessey Check Characters P
DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* PARAMETER DEFAULT OCIA USB Supplements are not Required * Two Digit Redundancy * OR RS232 TTL LIGHT IBM PEN 46XX KBW LASER EMULATION Five Digit Redundancy 100 msec to Find Supplement Configurable in 100msec steps (MAX 800 msec) * as code 39 Coupon Code 128 Configurable Code Lengths 7 avail. Configurable Prefix Characters 10 avail. Configurable Suffix Characters 10 avail.
DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* PARAMETER DEFAULT OCIA USB Supplements are not Required * Two Digit Redundancy * OR RS232 TTL LIGHT IBM PEN 46XX KBW LASER EMULATION Five Digit Redundancy 100 msec to Find Supplement Programmable in 100msec steps (MAX 800 msec) * as code 39 Coupon Code 128 Programmable Code Lengths 7 avail. Programmable Prefix Characters 10 avail. Programmable Suffix Characters 10 avail.
UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic’s new line of Flash- based scanners. This program allows the user of a Metrologic scanner to quickly upgrade to a new or custom version of firmware. It requires the use of a personal computer running Windows 95 or greater and the use of a serial port. The user merely connects the scanner to a serial port on the PC, launches the MetroSet2 program, and blasts off to new software upgrades.
SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS3580 scanner interfaces terminate to a 10-pin modular socket. The serial # label indicates the interface enabled when the scanner is shipped from the factory. Figure 19.
SCANNER AND CABLE TERMINATIONS MS3580-11 IBM 468X/469X Pin Function MS3580-9 OCIA Pin 1 2 3 4 5 6 7 Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input DTR Input IBM B-Transmit 1 2 3 4 5 6 7 8 IBM A+ Receive 8 9 10 +5VDC Shield Ground 9 10 Function Ground RS232 Transmit Output RS232 Receive Input RDATA RDATA Return Clock In Clock Out Clock in Return/ Clock out Rtrn +5VDC Shield Ground MS3580-104 RS232 TTL, Laser Emulation Pin 1 2 3 4 5 6 7 8 9 10 Function Ground RS232 Transmi
SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable MLPN 54-54000x -3 straight Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input/Light Pen Source 5 Power/Signal Ground 6 Light Pen Data 7 CTS Input 8 RTS Output 9 +5VDC 9 5 6 1 9-Pin D-Type Connector USB Power/Communication Cable MLPN 54-54213x-N-3, 54-54214x-N-3 or 54-54235x-N-3 Pin Function 1 PC +5V/V_USB 2 D- 3 D+ 4 Ground Shield Shield US
SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 54-54002x -3 Pin 1 2 3 4 5 Pin 1 2 3 4 5 6 Function Keyboard Clock Keyboard Data No Connect Power Ground +5 Volts DC Function PC Data No Connect Power Ground +5 Volts DC PC Clock No Connect 5-Pin DIN, Female 6-Pin DIN, Male Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other.
REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional.
REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Class A Devices Unintentional Radiators The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner dépassant 3 métres (9.
REGULATORY COMPLIANCE EMC Class B Devices Unintentional Radiators The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3 métres (9.8 pieds) de long en extension maximale: Folgendes trifft zu, wenn das Scannerkabel kürzer als 3 Meter ist: This device complies with Part 15 of the FCC Rules.
LIMITED WARRANTY The MS3580 QuantumT ® scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS3580 QuantumT scanners have a three (3) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS3580 QuantumT scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S.
PATENTS Patent Information This METROLOGIC product may be covered by, but is not limit to, one or more of the following U.S. Patents: U.S. Patent No.
INDEX A AC ....................................... 2, 8–12 Accessories ...............................2, 3 Adapter........................................10 Audible Indicator. 13, 19–21, 27–30, 39 B EMI ............................................. 45 emissions .................................... 45 F Failure Modes...................................... 21 Firmware ..................................... 39 Flash ROM.............................. 1, 39 Bar Code ............. 19–21, 27–30, 31 Bar Width....
INDEX Light Pen ........................... 8, 34–38 Light Source ................................31 M Maintenance..................................5 Manual............................... 2, 19, 33 MetroSet2....................................39 Mode of Operation Button ......................................18 Primary ..............................13–18 Secondary..........................13–18 Sweet Spot Mode ....................38 Motor Speed................................31 Mounting Specifications .....
51
NOTES
NOTES
November 2006 Printed in the USA 00 - 05090D