User Guide

HONEYWELL 5800 TO LORAWAN BRIDGE
COPYRIGHT © 2019, RADIO BRIDGE INC. HONEYWELL 5800 TO LORAWAN BRIDGE PAGE 5 OF 8
5.2. Uplink Messages
The uplink message (sensor to web application) specific to the bridge is defined in following
table. The common uplink messages are not included in this section (see common messages
document).
Table 5 Uplink Message 0x17: Honeywell Sensor Event
Bytes
Description
0-2
Honeywell Sensor ID (usually located on a sticker on the sensor)
3
Event identifier
4-5
Event payload
The events in byte 3 are defined in the following table.
Table 6 Honeywell Sensor Events
Event Identifier
Description
0x00
Status code
0x01
Error code
0x02
Sensor data payload
The Event Payload definitions for status codes, error codes, and sensor data payload are
described in the document “Honeywell 5800 BridgeBee User Guide” located on the Radio
Bridge website.
5.3. Downlink Messages
The only downlink messages available for the HW5800 bridge are defined in the common
messages document, and are not included in this section.