TrueFRESH™ ERV/HRV Ventilation Systems Systèmes de ventilation VRÉ/VRC TrueFRESH™ PROFESSIONAL INSTALLATION GUIDE. GUIDE D’INSTALLATION PROFESSIONNELLE. INCLUDED IN THIS BOX A1 A2 B G1 D E C G2 G3 F ERV/HRV Ventilation Systems PROFESSIONAL INSTALLATION GUIDE. GUIDE D’INSTALLATION PROFESSIONNELLE. INCLUDED IN THIS BOX A1 A2 B G1 D E C G2 G4 G3 F ERV/HRV Ventilation Systems PROFESSIONAL INSTALLATION GUIDE. GUIDE D’INSTALLATION PROFESSIONNELLE.
Installation Checklist Included in This Box A1 ERV/HRV VNT5150H1000 or VNT5150E1000 or A2 ERV/HRV VNT5200H1000 or VNT5200E1000 B Heat/Energy Recovery Core C Filter (2) D Installation Guide E Duct Collars (4) F Installation Kit Control Options (Sold separately) G1 - Vision Pro IAQ G2 - True IAQ G3 - Dehumidistat H8908D G4 - Prestige IAQ G5 - 20/40/60 Minute Boost Control G6 - W8150 Ventilation Control Tools Required (Not Supplied) • Aluminum foil tape (UL1818) • Standard screwdriver • Crescent wrench
TrueFRESH™ ERV/HRV Balanced Ventilation Systems ABOUT YOUR NEW VENTILATION SYSTEM Benefits........................................................................ 2 Determining Your Ventilation Needs........................... 3 Specifications.............................................................. 4 External Control Options............................................. 9 INSTALLATION Install to Fit Your Application.................................... 10 Installation Steps.............................
About the ERV/HRV Ventilation System The Honeywell TrueFRESH™ ERV/HRV Balanced Ventilation System provides improved indoor air quality through its high performance and efficiency. Benefits • • • • • Ventilation with sensible heat recovery (ERV and HRV) Ventilation with latent heat recovery (ERV only) Simplified mounting (hanging) Removable duct collars for easy ducting to the unit Intuitive balancing via two variable speed motors and a speed control CAUTION: Electrical shock and fire hazard.
Determining Your Ventilation Needs How much fresh air do you need? Good air quality is based in part on the capacity of the home’s ventilation system. Usually, the unit’s capacity is measured in CFM (Cubic Feet per Minute) or L/s (Liters per second) of fresh air being distributed in the living space. Use the ASHRAE 62.2 Ventilation Standard, the Room Count Calculation Method, or the Air Change Per Hour (ACH) Method to determine your ventilation needs. ASHRAE 62.2 Ventilation Standard ASHRAE 62.
Specifications Dimensions in inches (mm): 2 1 H 1 FRONT CLEARANCE OF 25 INCHES (635 MM) IS REQUIRED FOR SERVICING UNIT. 2 ALL DUCT CONNECTIONS ARE 6 IN. (150 MM). W L VNT5150H1000 or VNT5150E1000: H = 22 1/2 in. (572 mm), W = 11 1/2 in. (295 mm), L = 29 1/2 in. (749 mm) VNT5200H1000 or VNT5200E1000: H = 22 1/2 in. (572 mm), W = 16 1/2 in. (422 mm), L = 29 1/2 in.
Specifications (continued) VNT5150H1000 Ventilation Performance External Static Pressure Gross Air Flow Net Supply Air Flow Supply Exhaust Pa in. W.C. L/s CFM L/s CFM L/s CFM 25 0.1 92 195 92 196 113 241 50 0.2 85 182 86 183 105 223 75 0.3 80 171 81 172 91 193 100 0.4 73 156 74 157 84 178 125 0.5 65 139 66 140 75 159 150 0.6 59 126 60 127 65 137 175 0.7 56 120 57 120 57 120 200 0.8 50 107 50 107 48 103 225 0.
Specifications (continued) VNT5200H1000 Ventilation Performance External Static Pressure Gross Air Flow Net Supply Air Flow Supply Exhaust Pa in. W.C. L/s CFM L/s CFM L/s CFM 25 0.1 117 248 118 250 130 277 50 0.2 108 229 109 231 119 253 75 0.3 102 218 103 220 110 234 100 0.4 94 200 95 202 101 216 125 0.5 85 181 86 183 92 197 150 0.6 77 163 78 165 82 175 175 0.7 69 146 70 148 71 151 200 0.8 61 129 61 131 60 128 225 0.
Specifications (continued) VNT5150E1000 Ventilation Performance External Static Pressure Gross Air Flow Net Supply Air Flow Supply Exhaust Pa in. W.C. L/s CFM L/s CFM L/s CFM 25 0.1 92 197 96 204 93 199 50 0.2 87 185 93 199 88 186 75 0.3 82 173 88 186 82 175 100 0.4 75 160 83 176 76 162 125 0.5 69 146 76 162 70 148 150 0.6 62 132 72 152 63 134 175 0.7 55 116 67 143 55 117 200 0.8 48 102 60 127 48 103 225 0.
Specifications (continued) VNT5200E1000 Ventilation Performance External Static Pressure Gross Air Flow Net Supply Air Flow Supply Exhaust Pa in. W.C. L/s CFM L/s CFM L/s CFM 25 0.1 98 208 102 218 99 210 50 0.2 94 200 99 210 95 202 75 0.3 87 186 93 199 88 188 100 0.4 82 175 88 188 83 176 125 0.5 74 157 78 167 75 159 150 0.6 65 138 72 152 65 139 175 0.7 60 127 64 135 60 128 200 0.8 53 112 60 127 53 113 225 0.
External Control Options The ERV/HRV unit may be used with one of the following external controls: Prestige™ (YTHX9321R5012) and Prestige™ IAQ Comfort System (YTHX9421R5028) • Controls both heating/cooling and ventilation. • Wireless sensor for displaying outdoor temperature and humidity. • Advanced ventilation programming includes economizing and extreme condition shutdown. • Maintenance and service reminders. • High definition color display.
Install to Fit Your Application NOTE: Prior to installing, serious consideration must be taken to insure this ventilation system will operate properly if integrated with any other type of mechanical system, i.e. a forced air system, or an air handling unit. To insure proper operation & compatibilities of both system, it is required that the airflows of ventilation systems be balanced, by following the procedures found in this manual. Limitations: The product is for residential applications only.
Install to Fit Your Application (continued) B Exhaust at the Source and Supply in the Return STALE AIR FROM LIVING SPACE, SUCH AS FROM BATHROOM OR KITCHEN TO LIVING SPACE ET 3 FE 6 FE ET 18 INC HE S HRV / ERV FORCED AIR SYSTEM M28984 This application uses a devoted duct system for the exhausting of stale air accumulated in the home. The fresh air is introduced into the return air duct and is distributed through the home by the existing supply air ductwork of the forced air system.
Install to Fit Your Application (continued) C Exhaust and Supply in the Return 6 FEET 3 FEET TO LIVING SPACE 6 FE ET 18 INC HE S FORCED AIR SYSTEM HRV / ERV M28985 When using this application make sure that there is a minimum of 6 feet between the fresh air and exhaust air connections of the ERV/HRV unit in the return air duct. Supply air from the ERV/HRV unit must be at least 3 feet from the forced air system.
Installation Steps 1 Installation Kit Ensure that you have all of the following installation items: 4 Duct Collars Installation Kit: • • • • • • • • • 2 2 Flexible 6 in. Vinyl Ducts 1 Condensation Drain Line (10 in.) 1 Drain Adapter with Nut 4 Tie Wraps (30 in.) 16 Hex-head screws (1/4 x 5/8 in.) 4 Hex-head screws (1/4 x 1 in.
Installation Steps (continued) 3 Hanging the ERV/HRV The ERV/HRV unit enables you to save time and effort by offering a simplified hanging system. TIP: Removing the core unit makes installation easier since the unit weighs less without the core inside. 1. Attach straps to joist using the supplied washers and four 1 in. hex-head hanging screws. 2. Pull on middle of strap while gently lifting unit upward to raise the unit. 3. Make final adjustments to ensure that the HRV/ERV is level.
Installation Steps (continued) 4 Installing the flex duct to the ERV/HRV TIP: Honeywell recommends using approximately 16 inches of flexible duct (supplied in kit) between the unit and the rigid duct for noise dampening. The flex duct is mounted to the unit the same way as the insulated flex. 1. Insert the vinyl duct over the hooks on the duct collar and seal with a supplied 30 inch tie wrap. 2. Insert insulation inside the outer ring of the duct collar. 3.
Installation Steps (continued) 5 Installing the condensation drain line Insert the threaded drain adapter through the bottom of the unit and hand tighten the plastic nut supplied with the drain kit. Use a wrench to tighten the nut another half turn to ensure a complete seal. Install the condensate tubing by pushing the clear plastic tubing over the drain adapter. Make a condensate trap by looping the clear plastic tubing. This loop will prevent foul odors from entering the unit.
Installation Steps (continued) 6 Connecting the power cord ERV/HRV Power Cord Insert the power cord on top of the unit. Press firmly to make sure the power cord is secure. IMPORTANT: Do not plug the power cord into the wall receptacle at this time. Electric Wall Outlet Honeywell recommends that the unit has a dedicated receptacle with 120 VAC. Avoid connecting the unit to the wall receptacle with an extension cord. Honeywell does not recommend the use of an extension cord.
Automated Defrost The ERV and HRV units are equipped with an automatic defrost feature to eliminate any ice build up on the core. • Automatic defrost is initiated once every hour when the fresh air supply temperature drops to 23°F (-5°C) or colder. • The defrost cycle operates by turning off the supply fan while continuing to operate the exhaust fan. • The exhaust fan speed is adjusted proportionally based on the outdoor temperature, initially operating at low speed.
Wiring (continued) Wiring with Remote Controls CONT mode - Ventilator runs continuously on low speed. A ventilation call from a control boosts the ventilator into high speed. INT mode - The ventilator is OFF until a ventilation call from a wall control turns it on in high speed.. Controls Wiring THM5421R (24 VAC) R TO C THERMOSTAT CONV Follow this diagram if using a Prestige™ 2-wire IAQ and RF EIM.
Wiring (continued) Follow this diagram if using a Prestige™ Thermostat (Interlock not shown). PRESTIGE THEROMSTAT NOT USED POWERED VENTILATOR NOT USED C C Rc Rc R R U1 U1 U1 U1 U2 U2 U2 U2 U1/U1 Configurable IAQ relay for humidifier, dehumidifier, or vent U2/U2 Configurable IAQ relay for humidifier, dehumidifier, or vent M28988 VisionPRO IAQ Equipment Interface Module Follow this diagram if using a VisionPRO IAQ.
Wiring (continued) Follow this diagram for General Ventilator Wiring THERMOSTAT POWERED VENTILATOR VENTILATION CONTACTS C Y Y W W G G R R FURNACE 24-VOLT TERMINAL BLOCK M28990 ERV/HRV is used in conjunction with a conventional HEAT/COOL thermostat or other wall control.
Wiring (continued) Follow this diagram for Alternate Interlock Wiring with Forced Air System FAN TIMER OR OTHER WALL CONTROL POWERED VENTILATOR G C Y Y W W G R R FORCED AIR SYSTEM (FURNACE) 24-VOLT TERMINAL BLOCK OLDER -STYLE THERMOSTAT FAN (G) & COOL (Y) ARE COUPLED M28992 The ERV/HRV is interlocked with the forced air system and is used in conjunction with older-style thermostats where the G and Y terminals are coupled together in the thermostat (fan and cool are simultaneously energized).
Wiring (continued) Follow this diagram if using a Dehumidistat. M28994 EARD-6 AT120 XFMR W8150A DAMPER C R Follow this diagram if using a W8150 Ventilation Control REMOTE AUX FAN TIMER M28995 B G R Follow this diagram if using the Honeywell 20/40/60 Minute Boost Control Timer.
Control Panel LED The control panel has a 3-position selector switch and “+” and “–” buttons for speed control. The color of the LED indicator indicates the current function of the selector switch. • GREEN LED = Mode Control (normal operating mode) • YELLOW LED = Balancing Control Speed Control Open for Instructions 3-POSITION SELECTOR SWITCH SPEED CONTROL BUTTONS (+ AND -) M32371 Speed Control used as a Mode Control When the LED indicator is green, the selector switch functions as a Mode Selector.
Balancing Steps NOTE: Perform the balancing steps with the HVAC equipment fan turned ON if the ERV/HRV unit is ducted into an HVAC system. 1 a. Ensure that the speed control selector switch is in either the INTER or CONT position. b. Press the (+) and (–) buttons simultaneously for 5 seconds until the LED indicator light turns yellow, which indicates that you are in balancing mode. When in balancing mode, the selector switch becomes the motor selector switch.
Balancing Reset NOTE: Once balancing is completed, balancing cannot be changed without resetting the unit. LED To reset: Speed Control 1. Press the (+) and (–) buttons simultaneously for 10 seconds. 2. Indicator light will turn yellow at 5 seconds. 3. Indicator light will turn green at 10 seconds. 4. Release both buttons. 5. Unit has been reset and can be put into balancing mode again.
Maintenance Quarterly or as Needed 1 Filters. Four times per year or as needed, vacuum the filters. Replace filters as needed. Annually or as Needed 1 2 3 Inside the Unit. Once a year or as needed, clean the interior of the unit (walls and drain pan) with a mild and non abrasive soap. It is recommended to use products that are environmentally-friendly.
Cleaning Steps 1. Disconnect the AC power from the unit or the wall. 3. Clean inside of unit with a damp cloth and wipe dry when finished. 28 2. Open the side door panel by opening the two latches on the top of the side panel and lowering the panel to its fully open position Remove both filters from the top left and right sides of the Core, then vacuum both filters. Slide out the Core, and clean according to the instructions on the previous page. 4.
Troubleshooting CAUTION: Servicing the ERV/HRV unit with its electrical circuitry can cause personal injury. Always make sure that power to the unit is disconnected prior to making any connections. Failure to disconnect the power could result in electrical shock. Service should only be performed by a qualified service technician. Problem Recommended Troubleshooting Steps ERV/HRV unit not running 1. Verify polarization of electrical receptacle. 2. Verify breaker in electrical box. 3.
Honeywell OS and Parts List Honeywell OS List Honeywell OS Number Controls Ventilator Type VNT5150H1000 No HRV VNT5150E1000 No ERV VNT5200H1000 No HRV VNT5200E1000 No ERV Parts List (see illustration on page 31 for figure number references) Figure Number Honeywell Part Number Description 50053952-001 Polypropylene 10" HRV Core - VNT5150H1000 50053952-002 Polypropylene 15" HRV Core - VNT5200H1000 50053952-003 Enthalpy 10" ERV Core - VNT5150E1000 50053952-004 Enthalpy 15" ERV Core -
Parts Illustration See the Parts List table on page 30 for items referenced by figure numbers 1 through 11 in the exploded illustration below.
5-Year Limited Warranty Honeywell warrants this product to be free from defects in the workmanship or materials, under normal use and service, for a period of five (5) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option).
Systèmes de ventilation équilibrée VRÉ/VRC TrueFRESH™ À PROPOS DE VOTRE NOUVEAU SYSTÈME DE VENTILATION Avantages.................................................................. 34 Établissement de vos besoins en matière de ventilation.................................................................. 35 Caractéristiques........................................................ 36 Commandes externes en option.............................. 41 INSTALLATION (suite) Câblage du Déshumidistat H8908D.............
À propos du système de ventilation VRE/VRC Le système de ventilation équilibrée TrueFRESH™ améliore la qualité de l’air intérieur grâce à sa haute performance et son efficacité.
Établissement de vos besoins en matière de ventilation De quelle quantité d’air frais avez-vous besoin? Une bonne qualité d’air dépend en partie de la capacité du système de ventilation de la maison. On mesure habituellement la capacité d’un appareil en pi3/min (pieds cubes par minute) ou en l/s (litres par seconde) d’air frais redistribué dans les espaces habités. Utilisez la norme de ventilation résidentielle ASHRAE 62.
Caractéristiques Dimensions en mm (pouces) : 2 1 1 UN DÉGAGEMENT DE 635 MM (25 PO) EST NÉCESSAIRE DEVANT L’APPAREIL POUR SON ENTRETIEN. 2 TOUS LES RACCORDS DE CONDUIT ONT UN DIAMÈTRE DE 150 MM (6 PO).
Caractéristiques (suite) Performance du VNT5150H1000 en matière de ventilation Pression statique externe Débit d’air fourni net Débit d’air brut Débit d’air fourni Sortie Pa po c.e. l/s pi /min l/s pi /min l/s pi3/min 25 0.1 92 195 92 196 113 241 50 0.2 85 182 86 183 105 223 75 0.3 80 171 81 172 91 193 100 0.4 73 156 74 157 84 178 125 0.5 65 139 66 140 75 159 150 0.6 59 126 60 127 65 137 175 0.7 56 120 57 120 57 120 200 0.
Caractéristiques (suite) Performance du VNT5200H1000 en matière de ventilation Pression statique externe Débit d’air brut Débit d’air fourni net Débit d’air fourni Sortie Pa po c.e. l/s pi /min l/s pi /min l/s pi3/min 25 0.1 117 248 118 250 130 277 50 0.2 108 229 109 231 119 253 75 0.3 102 218 103 220 110 234 100 0.4 94 200 95 202 101 216 125 0.5 85 181 86 183 92 197 150 0.6 77 163 78 165 82 175 175 0.7 69 146 70 148 71 151 200 0.
Caractéristiques (suite) Performance du VNT5150E1000 en matière de ventilation Pression statique externe Débit d’air brut Débit d’air fourni net Débit d’air fourni Sortie Pa po c.e. l/s pi /min l/s pi /min l/s pi3/min 25 0.1 92 197 96 204 93 199 50 0.2 87 185 93 199 88 186 75 0.3 82 173 88 186 82 175 100 0.4 75 160 83 176 76 162 125 0.5 69 146 76 162 70 148 150 0.6 62 132 72 152 63 134 175 0.7 55 116 67 143 55 117 200 0.
Caractéristiques (suite) Performance du VNT5200E1000 en matière de ventilation Pression statique externe Débit d’air brut Débit d’air fourni net Débit d’air fourni Sortie Pa po c.e. l/s pi /min l/s pi /min l/s pi3/min 25 0.1 98 208 102 218 99 210 50 0.2 94 200 99 210 95 202 75 0.3 87 186 93 199 88 188 100 0.4 82 175 88 188 83 176 125 0.5 74 157 78 167 75 159 150 0.6 65 138 72 152 65 139 175 0.7 60 127 64 135 60 128 200 0.
Commandes externes en option Le VRE/VRC peut être utilisé avec l’une des commandes externes suivantes : Prestige™ (YTHX9321R5012) et système de régulation d’ambiance Prestige™ IAQ (YTHX9421R5028) • Règle à la fois le chauffage-refroidissement et la ventilation. • Capteur sans fil pour l’affichage de la température et du taux d’humidité extérieurs. • Programme de ventilation évolué qui comprend un cycle économiseur et l’interruption en cas de conditions extrêmes.
Installation selon votre utilisation REMARQUE : Avant l’installation du système de ventilation, il est important de s’assurer qu’il fonctionnera adéquatement s’il est intégré à un autre type de système mécanique (p. ex., un système à air pulsé ou un appareil de traitement de l’air). Dans le but d’assurer la compatibilité des systèmes et leur fonctionnement adéquat, leurs débits doivent être équilibrés selon les procédures décrites dans le présent manuel.
Installation selon votre utilisation (suite) B Évacuation dans la conduite d’entrée et apport dans la conduite de retour AIR VICIÉ DES ESPACES HABITÉS (COMME LES SALLES DE BAIN ET LA CUISINE) 1,83 45, 72 cm (18 4 cm 91,4 i) (3 p VERS LES ESPACES HABITÉS m (6 po) pi) VRC / VRÉ SYSTÈME À AIR PULSÉ MF28984 Cette application est fondée sur l’utilisation d’un système de conduits destiné à l’évacuation de l’air vicié de la maison.
Installation selon votre utilisation (suite) C Installation selon votre utilisation (suite) 1,83 m (6 pi) 91,44 cm (3 pi) VERS LES ESPACES HABITÉS 1,83 45, 72 cm (18 m (6 pi) po) SYSTÈME À AIR PULSÉ VRC / VRÉ MF28985 Si vous choisissez cette configuration, assurez-vous que les raccords des conduits d’air frais et d’air vicié du VRE/VRC au conduit de retour d’air sont situés à au moins 1,83 m (6 pi) l’un de l’autre.
Procédure d’installation 1 Trousse de quincaillerie Assurez-vous d’avoir les articles suivants en main avant d’installer le produit : 4 raccords de conduit Trousse de quincaillerie : • • • • • • • • 2 gaines flexibles en vinyle de 6 po 1 tuyau d’évacuation de condensation (10 po) 1 adaptateur de tuyau d’évacuation avec écrou 4 attaches autobloquantes (76,20 cm [30 po]) 16 vis à tête hexagonale (1/4 x 5/8 po) 4 vis à tête hexagonale (1/4 x 1 po) 4 rondelles 1 bouchon de vidange (VNT5250E100 et VNT5200E
Procédure d’installation (suite) 3 Suspension du VRE/VRC Le système de suspension simplifié du VRE/VRC permet une installation rapide et facile. CONSEIL : Le fait de retirer le noyau allège l’appareil et facilite l’installation de ce dernier. 1. Fixez les courroies aux solives à l’aide des rondelles fournies et de quatre vis de suspension de 1 po à tête hexagonale. 2. Tirez le milieu de la courroie tout en soulevant doucement l’appareil. 3.
Procédure d’installation (suite) 4 CONSEIL : Installation de la gaine flexible au VRE/VRC Honeywell recommande d’utiliser 40,64 cm (16 po) de gaine flexible (fournie dans la trousse) entre l’appareil et le conduit rigide afin d’atténuer le bruit. La gaine flexible se fixe à l’appareil de la même manière que la gaine flexible isolée. 1.
Procédure d’installation (suite) 5 Installation du tuyau d’évacuation des condensats Insérez l’adaptateur de tuyau d’évacuation fileté sous l’appareil et resserrez à la main l’écrou en plastique fourni dans l’ensemble du tuyau d’évacuation. Utilisez une clé pour serrer l’écrou d’un demi-tour supplémentaire afin d’assurer l’étanchéité du raccord. Installez le tuyau d’évacuation de condensation en poussant le tube de plastique transparent autour de l’adaptateur de tuyau.
Procédure d’installation (suite) 6 Cordon d’alimentation du VRE/VRC Cordon d’alimentation Insérez le cordon d’alimentation sur le dessus de l’appareil. Appuyez fermement afin de vous assurer que la connexion est solide. IMPORTANT : Ne branchez pas encore le cordon d’alimentation dans le mur. Prise murale Honeywell recommande que l’appareil soit branché à une prise réservée de 120 V c.a. Évitez d’utiliser une rallonge électrique pour brancher l’appareil à une prise murale.
Dégivrage automatique Les appareils VRE et VRC sont munis d’une fonction de dégivrage automatique afin d’éliminer la glace susceptible de se former sur le noyau. • Lorsque la température de l’air frais qui entre dans le système est inférieure à -5 °C (23 °F) ou moins, la fonction de dégivrage automatique se met en marche une fois l’heure. • Cette fonction éteint le ventilateur d’arrivée tout en maintenant allumé le ventilateur d’évacuation.
Câblage (suite) Câblage pour un fonctionnement avec commande à distance Mode CONT (continu) : le ventilateur fonctionne en continu à basse vitesse; une commande augmente ensuite la vitesse. Mode INTER (intermittent) : le ventilateur est éteint jusqu’à ce qu’on le mette en marche en haute vitesse, à partir d’une commande murale.
Câblage (suite) Suivez ce schéma si vous utilisez un thermostat Prestige™ (verrouillage non représenté).
Câblage (suite) Suivez ce schéma pour le câblage général du ventilateur. ALIMENTATION DU VENTILATEUR THERMOSTAT CONTACTS DE VENTILATION C Y Y W W G G R R BLOC DE RACCORD 24 VOLTS POUR L’APPAREIL DE CHAUFFAGE MF28990 Le VRE/VRC est utilisé de concert avec un thermostat à commande de chauffage et de refroidissement classique ou un autre type de commande murale.
Câblage (suite) Suivez ce schéma pour l’autre option de raccord au système à air pulsé. ALIMENTATION DU VENTILATEUR MINUTERIE DU VENTILATEUR ET AUTRES COMMANDES MURALES G C Y Y W W G R R L’ANCIEN MODÈLE DE VENTILATEUR AVEC THERMOSTAT (G) ET LE SYSTÈME DE REFROIDISSEMENT (Y) SONT COUPLÉS.
Câblage (suite) Suivez ce schéma si vous utilisez un déshumidistat. M28994 EARD-6 Suivez ce schéma si vous utilisez un régulateur W8150. AT120 XFMR DAMPER C R W8150A REMOTE AUX MINUTERIE MF28995 B G R Suivez ce schéma si vous utilisez la minuterie Honeywell pour la ventilation à haute vitesse (20, 40 ou 60 minutes).
Panneau de commande DEL Le panneau de commande dispose d’un sélecteur à trois positions et de boutons « + » et « – » pour régler la vitesse. La couleur du voyant DEL indique à quelle fonction est réglé le sélecteur.
Procédure d’équilibrage REMARQUE : Avant l’équilibrage, assurez-vous que le ventilateur du système CVCA est en marche (si l’appareil VRE/VRC est connecté à un tel système). 1 a. Assurez-vous que le sélecteur de vitesse est à la position INTER ou CONT. b. Appuyez simultanément sur les boutons + et – simultanément pendant 5 secondes jusqu’à ce que le voyant DEL vire au jaune, ce qui indique que vous êtes au mode équilibrage.
Réinitialisation de l’équilibrage REMARQUE : L’appareil doit être réinitialisé avant chaque nouvelle procédure d’équilibrage. Réinitialisation : DEL 1. Appuyez simultanément sur les touches + et – pendant 10 secondes. 2. Le voyant deviendra jaune après 5 secondes. 3. Le voyant deviendra vert après 10 secondes. 4. Relâchez les deux boutons. 5. L’appareil est réinitialisé et peut être mis de nouveau au mode équilibrage.
Entretien Aux trois mois (ou selon le besoin) 1 Filtres. Nettoyez les filtres à l’aide d’un aspirateur (quatre fois par année, ou au besoin). Remplacez les filtres au besoin. Tous les ans (ou selon le besoin) 1 2 3 Intérieur de l’appareil. Une fois par an ou au besoin, nettoyez l’intérieur de l’appareil (parois et bac à récupération) avec un savon doux non abrasif. L’utilisation de produits respectueux de l’environnement est recommandée.
Procédure d’entretien 60 1. Coupez l’alimentation en c.a. en retirant la fiche enfoncée dans l’appareil ou celle qui est branchée sur la prise de courant. 2. Ouvrez le panneau de porte latérale en ouvrant les deux loquets situés en haut et en abaissant le panneau jusqu’à ce qu’il soit complètement ouvert. Retirez les deux filtres situés en haut, à gauche et à droite du noyau, puis nettoyez-les à l’aide d’un aspirateur.
Dépannage MISE EN GARDE : L’entretien du VRE/VRC et de son système électrique peut entraîner des blessures. Assurez-vous que l’alimentation électrique est débranchée avant d’effectuer toute connexion. Le non-respect de cette directive peut causer une décharge électrique. L’entretien doit être effectué seulement par un technicien qualifié. Problème Recommandations pour le dépannage L’appareil VRE/VRC ne fonctionne pas. 1. Vérifiez la polarisation de la prise de courant. 2.
Honeywell : listes de modèles et de pièces Honeywell : liste de modèles Honeywell : numéro de produit Numéro de contrôle Type de ventilateur VNT5150H1000 Non VRC VNT5150E1000 Non VRE VNT5200H1000 Non VRC VNT5200E1000 Non VRE Liste des pièces (reportez-vous à l’illustration de la page 31 pour obtenir la référence visuelle associée à chaque numéro) Numéro (illustration) Numéro de pièce Honeywell Description 50053952-001 Noyau VRC 25,4 cm en polypropylène –VNT5150H1000 50053952-002 Noyau
Illustration des pièces Voir le tableau Liste des pièces à la page 62 : les articles sont référencés par numéros (1 à 11) correspondant aux numéros de la vue éclatée ci-dessous.
64 Systèmes de ventilation VRÉ/VRC TrueFRESH™ 69-2480EF—05
Systèmes de ventilation VRÉ/VRC TrueFRESH™ 69-2480EF—05 65
Garantie limitée de 5 ans Honeywell garantit que ce produit ne présentera aucun défaut de matériaux ou de fabrication dans des conditions normales d’utilisation et d’entretien pour une période de cinq (5) ans à compter de la date de l’achat par le consommateur. Honeywell choisira de réparer ou de remplacer ce produit si celui-ci présente un défaut ou un problème de fonctionnement pendant la période de garantie.