TABLE 5. OPERATING SPECIFICATIONS
CHARACTERISTIC
ANALOG DIGITAL
UNIT
MIN. TYP. MAX. MIN. T YP. MAX.
Supply voltage (V
supply
):
1, 2, 3
3.3 Vdc
5.0 Vdc
3.0
4.75
3.3
5.0
3.6
5.25
3.0
4.75
3.3
5.0
3.6
5.25
Vdc
Supply current:
3.3 Vdc
5.0 Vdc
sleep mode option
—
—
—
2.1
2.7
—
2.8
3.8
—
—
—
—
3.1
3.7
1
3.9
4.6
10
mA
mA
uA
Operating temperature range
4
-40 [-40] — 85 [185] -40 [-40] — 85 [185] °C [°F]
Compensated temperature range
5
0 [-32] — 50 [122] 0 [-32] — 50 [122] °C [°F]
Temperature output option
6
— — — — ±4 — °C
Startup time (power up to data ready) — — 5 — — 3 ms
Response time — 1 — — 0.46 — ms
Clipping limit:
upper
lower
—
2.5
—
—
97.5
—
—
—
—
—
—
—
%Vsupply
I
2
C/SPI voltage level:
low
high
—
—
—
—
—
—
—
80
—
—
20
—
%Vsupply
Pull up on SDA/MISO, SCL/SCLK, SS — — — 1 — — kOhm
Total Error Band
7
— — ±1.5 — — ±1.5 %FSS
8
Accuracy
9
— — ±0.25 — — ±0.25 %FSS BFSL
Long term stability (1000 hr, 25°C [77°F]) — — ±0.25 — — ±0.25 %FSS
Output resolution
0.03
—
—
—
—
—
—
12
—
—
—
—
%FSS
bits
1
Sensors are either 3.3 Vdc or 5.0 Vdc based on the catalog listing selected.
2
Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified
operating voltage.
3
The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause
electrical failure.
4
Operating temperature range: The temperature range over which the sensor will produce an output proportional to pressure.
5
Compensated temperature range: The temperature range over which the sensor will produce an output proportional to
pressure within the specified performance limits.
6
Temperature output option: Typical temperature output error over the compensated temperature range of 0°C to 50°C.
Operation in Sleep Mode may affect temperature output error depending on duty cycle.
7
Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and
pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability,
thermal effect on offset, thermal effect on span, and thermal hysteresis.
8
Full Scale Span (FSS): The algebraic difference between the output signal measured at the maximum (Pmax.) and minimum
(Pmin.) limits of the pressure range. (See Figure 2.)
9
Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the
pressure range at 25°C [77°F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.
TABLE 6. SENSOR OUTPUT AT SIGNIFICANT PERCENTAGES (DIGITAL VERSIONS ONLY)
% OUTPUT
DIGITAL COUNTS
DECIMAL HEX
0 0 0x0000
10 1638 0x0666
50 8192 0x2000
90 14746 0x399A
100 16383 0x3FFF