Programming Manual

Setting Schedules (Installer Code + [#] + [6] [4])
ENTER SCHED NO.
VISTA-20P: 01-16 = end-user schedules; 17-32 = installer-only schedules
VISTA-15P: 01-04 = end-user schedules; 05-08- = installer-only schedules
[] to continue.
To Quit, enter 00.
ENTER EVENT
00 = clear event
01 = Relay On/Off
02 = User Access
03 = Latch Key Report to Pager (sent to all pagers in the user’s partition;
message sent is 777-7777. User must be enabled for paging and
system must be armed before reporting can occur.)
04 = Forced Stay Arming
(
Forced bypass is automatically enabled
regardless of setting in field *23)
05 = Forced Away Arming
(
Forced bypass is automatically enabled
regardless of setting in field *23)
06 = Auto Disarm
07 = Display “Reminder”
10 = Display custom words (if selected, system displays custom words 8, 9,
and 10 at defined time. Can be used as installer’s reminder message
to the end user); programmable by installer only
11 = Periodic Test Report (see key commands in Test Report Code, data
field *64, to quickly set periodic test reporting intervals); programmable
by installer only
[] to continue.
DEVICE NUMBER (for event 1 relay on/off)
01-18; [] to continue.
GROUP NUMBER ( for event 2 user access)
1-8; [] to continue.
PARTITION ( for events 3-7,10,12)
0 = all partitions; 1 = partition 1; 2 = partition 2; 3 = common
[] to continue.
START
01-12 = hour; 00-59 = minute; 0 = AM; 1 = PM; to select days, position the
cursor under the desired days using the [] key to move forward, then press
“1” to select the day.
[] to continue.
STOP (for events 1 relay on/off; 2 user access; 3 latch key report)
See START for entries. [] to continue.
REPEAT
0 = do not repeat; 1 = repeat schedule weekly; 2 = repeat schedule biweekly
(every other week); 3 = repeat schedule every third week; 4 = repeat
schedule every fourth week
[] to continue
RANDOMIZE (for events 01 and 11)
0 = no; 1 = yes
If selected, the scheduled start and stop times will vary within 60 minutes of
the “hour” time. For example, if a schedule is set to start at 6:15pm, it will do
so the first time 6:15pm arrives, but on subsequent days it will start anytime
between 6:00 and 6:59 p.m.
NOTE: Do not use the random option if the start and stop times are within
the same “hour” setting, otherwise unpredictable results may occur (e.g., the
randomized stop time may occur before the start time).
[] to continue and return to ENTER SCHED NO. prompt to program the
next schedule.
SCHEDULES WORKSHEET(installer code + [#] + [6] [4];
master code can only access schedules 01-16 for VISTA-20P, 01-04 for
VISTA-15P, and events 00-07 for both controls; VISTA-15P supports up to 8 schedules, VISTA-20P supports up to 32 schedules
)
No. Event Device No. Group No. Partition Start Time/ Stop Time/ Repeat Random
(see list below) for “01” events: for “02” events: for “04-06” events: Days Days (1-4) (yes/no)
enter 01-18 enter 1-8 enter 1, 2, or 3
(VISTA-20P)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Events: Master/Installer Installer Only
00 = clear event 04 = forced STAY arm 10 = display custom words 8-10
01 = device on/off 05 = forced AWAY arm 11 = periodic test report
02 = user access 06 = auto disarm
03 = latch key report 07 = display “reminder”
Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week