Datasheet

Airflow Sensors AWM40000 Series
Microbridge Mass Airflow/Unamplified and Amplified
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
77
AWM40000 SERIES ORDER GUIDE (Performance Characteristics @ 10.01 ±0.01 VDC, 25°C)
Catalog Listings AWM42150VH AWM42300V AWM43300V AWM43600V
Flow Range (Full Scale) ±25 sccm ±1000 sccm +1000 sccm +6 SLPM
Output Voltage @ Trim Point 8.5 mV ±1.5 mV
@ 25 sccm
54.7 mV ±3.7 mV DC
@ 1000 sccm
5 V ±0.15 VDC
@ 1000 sccm
5 V ±0.15 VDC @ 6 SLPM
Null Voltage 0.0 ±1.0 mVDC 0.0 ±1.5 mVDC 1.0 ±0.05 VDC 1.0 ±0.05 VDC
Null Voltage Shift
+25° to 25°C, +25° to +85°C ±0.20 mVDC ±0.20 mVDC ±0.025 VDC ±0.025 VDC
Output Voltage Shift
+25° to 25°C +2.5% Reading typ. +2.5% Reading max. 5.0% Reading max. 6.0% Reading max.
+25° to +85°C 2.5% Reading typ. 2.5% Reading max. +6.0% Reading max. +6.0% Reading max.
Power Consumption (mW) 60 (Max.) 60 (Max.) 60 (Max.) 75 (Max.)
Repeatability & Hysteresis ±0.35% Reading (3) ±0.50% Reading ±0.50% Reading ±1.00% Reading
Pressure Drop @ Full Scale
(in H
2
O) 0.008N H
2
O (Typ.) 1.02 (Typ.) 1.02 (Typ.) 8.00 (Typ.)
Min. Typ. Max.
Excitation VDC 8.0 10±0.01 15
Response Time (msec) 1.0 3.0 (Note 1)
Common Mode
Pressure (psi) (max.) 150 psi (10 Bar) 25 psi (1.7 Bar)
Output Load NPN (Sinking): 10 mA
PNP (Sourcing): 20 mA
Temperature Range Operating: 40° to +125°C (40° to +251°F) Operating: 25° to +85°C (13° to +185°F)
Storage: 40° to +125°C (40° to +251°F) Storage: 40° to +90°C (40° to +194°F)
Calibration Gas Nitrogen
Ratiometricity Error ±0.30% Reading
Weight (grams) 14 g 11 g
Shock Rating 100 g peak (5 drops, 6 axes)
Termination 2,54 mm (.100N) centers, 0,635 cm (0.025N) square
Notes:
1. Response time is typically 1 msec from 10 to 90%.
2. Repeatability & Hysteresis tolerances reflect inherent inaccuracies of the measurement equipment.
3. Maximum allowable rate of flow change to prevent damage: 5.0 SLPM/1.0 sec.
MOUNTING DIMENSIONS (for reference only)
Amplified Sensors Unamplified Sensors
Note: Positive flow direction is defined as proceeding from
Port 1 (P1) to Port 2 (P2), and results in positive output.
Airflow