Product Manual

BW Clip
2 OR 3 YEAR H
2
S, CO, O
2
, SO
2
SINGLE-GAS DETECTOR
Part Number 50115903-067 | OM-EN-PALO-A8 | BW Clip Operator Manual
BW Clip is a portable, single-gas detector manufactured by
BW Technologies by Honeywell (BW). BW Clip continuously measures the
concentration of a specific gas in the ambient environment, and activates an alarm
when concentrations exceed alarm setpoints. It is your responsibility to respond
appropriately to the alarms.
BW Clip is a member of the GasAlert family of products. It is compatible with
IntelliDoX and MicroDock II automatic test and calibration stations, as well as Fleet
Manager II software version 4.0 or higher. For more information, visit the product
website at www.honeywellanalytics.com
Safety Information: Read First
1. Substitution of components may impair Intrinsic Safety.
2. Periodically test the response of the sensor by exposing the detector to a
target gas concentration that exceeds the low alarm setpoint. Manually verify
that the audible and visual alarms are activated.
3. Detectors in hibernation mode are not functional.
1. Activate the detector before the activation date on the package.
2. This product is a gas detector, not a measurement device.
3. Ensure that the sensor grill is free of dirt, debris, and is not obstructed.
4. Clean the exterior with a soft, damp cloth.
5. Bump test the detector in a normal atmosphere that is free of hazardous gas.
6. For optimal performance, periodically zero the sensor in a normal atmosphere
(20.9% v/v O
2
) that is free of hazardous gas.
Informations de sécurité – À lire au préalable
AVERTISSEMENT
1.
2.
Le remplacement d’un composant de l’appareil peut compromettre la sécurité
intrinsèque du détecteur.
Testez périodiquement la réponse du capteur en exposant le détecteur à une
concentration de gaz supérieure au seuil d’alarme basse. Vérifiez manuellement
que les alarmes sonores et visuelles sont activées.
3. Détecteurs en mode veille prolongée ne sont pas fonctionnels.
MISE EN GARDE
1. Activez le détecteur avant la date d’activation sur l’emballage.
2. Ce produit est un détecteur de gaz, pas un dispositif de mesure.
3. Veillez à assurer que la grille du capteur est exempt de saleté, les
débris, et ne soit pas obstrué.
4. Nettoyez l’extérieur de l’appareil à l’aide d’un chiffon doux et humide.
5. Veillez à effectuer un test fonctionnel du capteur dans une atmosphère normale
qui est exempte de gaz dangereux
6. Pour des performances optimales, zéro périodiquement le capteur dans une
atmosphère normale (20,9% v/v O
2
) qui est exempte de gaz dangereux.
BW Clip Factory Calibration Certificate
This instrument was factory inspected, tested and calibrated in accordance with the conditions and
requirements of our registered Quality System, Operating Standards and Sales Agreements.
Getting Started
PushbuttonPushbutton
Sensor and
sensor grill
Sensor and
sensor grill
Bubble label
with product name
and gas type
Bubble label
with product name
and gas type
Audible
alarm
Audible
alarm
LCDLCD
LED
visual alarms
LED
visual alarms
Infrared port
Alligator
clip
Product label
LCD and Symbols
Pushbutton prompt. When this symbol is displayed, press
and hold the pushbutton until the symbol disappears.
BW Clip O
2
models only. Oxygen concentration is
measured as percent by volume.
BW Clip H
2
S, CO and SO
2
models only. Toxic gas
concentration is measured in parts per million.
Low alarm and high alarm. These symbols are
displayed when a gas concentration that exceeds alarm
setpoints is detected.
Non-compliance warning. This symbol is displayed when a
diagnostic or compliance test fails; when the operating life
countdown reaches 24 hours or less; and for up to 30 days
after operating life expiry. It is also displayed when certain
notifications are enabled through Fleet Manager II via an
IntelliDoX station.
Real-time clock. This symbol is displayed when real-time
clock is enabled through Fleet Manager II via an IntelliDoX
station.
End of operating life warning. This symbol is displayed when
the operating life countdown reaches 24 hours or less.
Peak reading. This symbol is displayed when a maximum gas
exposure event has occurred within the past 24 hours.
Operating life remaining in months (MM) or days (DD).
a WARNING
a CAUTION
Bump test reminder. If the detector is configured to
display a
bump test reminder, this symbol is displayed when a bump
test is due.
indicates a failed test.
BW Clip O
2
models only. This symbol is displayed when more
than 24 hours have elapsed since the last
successful zero
procedure was performed. indicates a failed test.

Summary of content (4 pages)