notherm IV T8600D User guide

T8600D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS
69-1409—1 6
Table 3. Thermostat Installer Setup Options.
Select
Installer Setup
Number
(Press Time
key to
change)
Factory Setting
Other Choices
(Press or key to change)
Actual
SettingDisplay Description Display Description
Not used. 1
Fan
operation
a
.
2 0 Conventional
applications
where equipment
controls fan
operation in heat
mode.
1 Heat pump or electric heat
applications where
thermostat controls fan
operation in heat mode.
Not used. 3
Heating
cycle rate.
4 6 6—6 cph used
for conventional
heat.
1, 3, or
9
1—1 cph used for radiant
floor heat, gravity
system.
3—3 cph used for hot
water systems or high
efficiency furnaces.
9—9 cph used for electric
heat systems.
Not used. 5 thru 11
System
setting
adjustment
12 1 Manual
changeover
0 or 2 0—Auto changeover.
2—Auto only
Adaptive
Intelligent
Recovery™
control.
13 0 Adaptive
Intelligent
Recovery™
control is
activated (system
starts early so
setpoint is
reached by start
of program
period).
1 Conventional recovery
(system starts recovery at
programmed time).
Degree
temperature
display
14 0 Temperature is
displayed in °F
1 Temperature is displayed
in °C
Not used. 15
Clock
format.
16 0 12-hour clock
format.
1 24-hour clock format.
Not used. 17 and 18
Extended
fan operation
in heating
a
19 0 No extended fan
operation after
the call for heat
ends.
1 Fan operation is extended
90 seconds after the call
for heat ends.
Extended
fan operation
in cooling
20 0 No extended fan
operation after
the call for cool
ends.
1 Fan operation is extended
90 seconds after the call
for cool ends.
Not used. 21 thru 23