Portable Evaporative Air Cooler for Outdoor & Indoor Use Evaporativo Portátil Enfriador De Aire para uso en el Interior y en el Exterior 0 3 OFF ON 2 OFF 1 ON COOL SPEED SWING Portatif Évaporatif Refroidisseur D'air pour usage Extérieur et Intérieur OWNER’S MANUAL Read and save these instructions before use MAX MANUAL DEL PROPIETARIO MIN Lea y guarde estas instrucciones antes de usar la unidad MANUEL DU PROPRIÉTAIRE Lire et conserver ces instructions avant utilisation Model / Modelo / Mod
QUICK START GUIDE 1 2 3 Fill with water and plug into a standard power outlet. Note: Please make sure the household power voltage matches the product specifications. Place near an open door or window. Note : Evaporative air cooler requires cross ventilation. Turn ON and enjoy the cooling breeze. Note: Start with LOW speed and gradually increase to higher speed for optimum cooling performance.
INDEX Read all instructions carefully before setting up and operating the cooler, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty. SECTION 1. 2. 3. 4. 5. PAGE THANK YOU ................................................................................................
THANK YOU Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling from your cooler, fill the water tank to maximum level and load ice inside the ice compartment before you turn on your air cooler. Cooler Location - Indoors (Important - Please Read!) Place the cooler in front of an open door or window. Ensure that there is adequate cross - ventilation in the room by leaving a door or window open opposite the cooler.
USER TIPS Energy Efficient, No Compressor Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low. Warm air is drawn into the cooler through a dust and odor-reducing carbon filter and enters the Honeycomb Cooling Media. Water pumped from the tank pours over the honeycomb media. As the warm air passes through the media, the water absorbs the heat, naturally cooling and humidifying the air. A fan propels the cooled air out into the room.
USER TIPS Indoor Use The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low. The evaporative air cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. The room should have doors and windows opened to allow free air flow.
SAFETY READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: 120V - 60 Hz SHOCK HAZARD 0 3 OFF 1 ON COOL ON OFF 2 • Your cooler runs on 120 Volt AC, 60 Hz current. Check the household voltage to ensure it matches the appliance's rate specification. • Before operating the product remove it from its packaging and check that it is in good condition. • DO NOT operate any product with a damaged cord or plug.
SAFETY • DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty. • DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. • DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause an electrical shock or fire. • DO NOT operate with the Honeycomb Cooling Media removed as this will overload and damage the motor.
SAFETY • Use Only on GFCI Protected Receptacles. • Power cords have to be contained. If they must run along the ground, make sure every inch of them is secured so they will not be tripped over. • The wiring and connections must be waterproof. Be sure the connections (to the air cooler) never get wet. Your unit is waterproof, but everything attached to it must be waterproof, too. • Set up your unit so it cannot be tripped over or wobble loose. It must rest on a solid support.
PARTS DESCRIPTION 0 3 1 ON 1 OFF 2 OFF COOL ON 9 16 SPEED SWING 15 2 13 3 14 4 10 MAX MIN 8 5 11 6 12 1 Water Inlet and Ice Loading Compartment 2 Handle 3 Left Honeycomb Panel 4 Lever for Horizontal Louvers 5 Water Tank 6 Casters 7 Horizontal Louvers 8 Water Level Indicator 8 7 9 Control Panel 10 Right Honeycomb Panel 11 Continuous Water Supply Connection 12 Drain Plug 13 Backside Honeycomb Panel 14 Power Cord & Plug 15 Rear Grill Removal Screws 16 Water Fill Door
USE & OPERATION Control Panel OFF ON 0 3 OFF ON 2 1 SWING SPEED COOL 9
USE & OPERATION Control Knobs SPEED / ON - OFF Connect to the power supply and turn the SPEED knob. The fan will start. Change the speed from 1 to 3 (1 for Low, 2 for Medium and 3 for High fan speed). To switch OFF the unit, turn the SPEED knob to 0. 0 3 1 SPEED COOL To begin cooling the desired area, turn the COOL knob to the ON position. The water pump will operate. The cooler air will be felt after the Honeycomb Cooling Media is completely wet.
USE & OPERATION CAUTION • Unplug from power when refilling. Filling With Water Water can be filled into the air cooler water tank in two ways: Water Inlet (Manual Refill) Water / Ice can be put into the tank through the top opening. There is a hole for water to flow into the tank. Continuous Water Supply (Auto Water Refill) Connect a garden hose to the Continuous Water Supply inlet.
USE & OPERATION Continuous Water Supply (Auto Water Refill) CAUTION Unplug from power source before filling water. This automated process eliminates the need to manually refill the water tank. • Connect the garden hose to the water supply connector (# 11 on Page 8). • Verify that connections are secure and turn on the water (Maximum water inlet pressure is 0.5 MPa). • The water tank will refill automatically. • Plug the unit into the power supply and turn the unit on.
CLEANING & MAINTENANCE Important • The cooler is supplied with Honeycomb Cooling Media. • The cleaning frequency for the Honeycomb Capitalize Media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water reservoir and refilling with fresh water at least once a week will help reduce mineral deposits.
CLEANING & MAINTENANCE Draining and Cleaning The Water Tank • • • • Turn the power OFF and disconnect the air cooler from the power supply. Move the unit to a location where it can be drained. Remove the drain plug and allow the tank to empty (#12 on Page 8). Refill the water tank to maximum level with clean water and drain it completely. • Fill the water tank and rinse at least 2-3 times before use. Water Drain After cleaning ensure that the drain plug is back in place.
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air Cord is not plugged in. Make sure power cord is plugged in and the supply switch is on. Power is not ON. Turn the unit ON by changing the mechanical knob position on the control panel. Pump is not turned ON. Turn on COOL function from remote or control panel. Low or no water in tank, when COOL is selected. Refill water tank. Damaged Pump or Calcium deposits on blower. Contact Customer Service Center.
TECHNICAL SPECIFICATIONS MODEL NO. Voltage Frequency Wattage Ampere Water Tank Capacity Cooling Media Product Dimension (inches) Net Weight 16 CO48PM 120 V 60 Hz 150 Watts 1.25A 10.6 Gallons Honeycomb 24.4(W) X 14.8(D) X 34.8(H) 28.
ELECTRICAL WIRING DIAGRAM 17