Portable Evaporative Air Cooler User Manual Read and save these instructions before use 0 3 OFF ON 2 OFF 1 ON COOL SPEED SWING MAX Scan here: MIN www.honeywellaircoolers.com www.jmatek.com E-mail: usinfo@jmatek.
PARTS DESCRIPTION (17) 0 OFF 3 1 ON (1) OFF ON (9) 2 (16) SWING COOL SPEED (15) (2) (13) (3) (4) (14) (10) (8) (5) (11) (6) (7) (12) 1) Water Inlet Hole 2) Handle 3) Left Side Grill 4) Lever for Horizontal Louvers 5) Water Tank 6) Casters 7) Louvers 8) Water Level Indicator 9) Control Panel 10) Right Side Grill 11) Water Inlet Valve 12) Drain Plug 13) Rear Grill 14) Power Cord & Plug 15) Rear Grill Screws 16) Water Fill Door 17) Honeycomb Cooling Media WARNING -- READ AND SAVE THE
USE & OPERATION (CONTINUED) FUNCTION BUTTONS (CONTINUED) COOL You must add water before operating the unit on Cool mode. Turn the COOL knob to the ON position to activate evaporative cooling. The water pump will operate and you will feel the cooler air after the Honeycomb Cooling Media is completely wet. SWING Turn the SWING knob to the ON position to activate the movement of the louvers. The louvers will begin to move left to right automatically.
USE & OPERATION (CONTINUED) FILLING WITH WATER (CONTINUED) Manual Water Tank Refill: t Using a portable container or a garden hose, you can refill the water tank manually by pouring water into the water tank through the water inlet hole located at the top of the air cooler. t Check the water level indicator to know when the water tank is full. Do not fill water above the "Max." water level mark to avoid water droplets collecting on the louvers.
USE & OPERATION (CONTINUED) CLEANING THE HONEYCOMB COOLING MEDIA (CONTINUED) t The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits.
TECHNICAL SPECIFICATIONS Model CO48PM Voltage 110 ~ 120V Frequency 60Hz Ampere 1.25A Wattage 150W Cooling Media Honeycomb Product Dimensio 620 (W) x 375 (D) x 883 (H) mm 24.4 (W) x 14.8 (D) x 34.8 (H) in Net Weight 14 kg / 30.9 lbs ELECTRICAL WIRING DIAGRAM For USA Outdoor Models Only. This appliance is equipped with a GFCI plug. Press the TEST button and then the RESET button once every month to ensure proper operation. Version: 110~120V/60Hz * *Low water cut-off.
JMATEK North America LLC Mahwah, New Jersey 07495 USA Phone: 1-800-474-2147 Email: usinfo@jmatek.com Web: www.jmatek.com © 2016 JMATEK Limited. All rights reserved. The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representations or warranties with respect to these products. This product is manufactured by Airtek Int'l Corp. Ltd. (subsidiary of JMATEK Ltd.