CT87N1001 Round Thermostat Manual

T87N Easy-To-See
TM
• Owner's Manual
69-1840EFS—07 2
System Types
Gas, oil, or electric heat with air
conditioning
Warm air, hot water, high-efficiency
furnaces, heat pumps, steam, gravity
Heat only
Heat only with fan
Cool only
System Settings
Heat, Off, Cool
Fan Settings
Auto, On
Specifications
Temperature Range
40° to 90°F (4.5° to 32°C)
Shipping Temperature
20° to 120°F (28.9° to 48.9°C)
Operating Relative Humidity
5% to 90% (non-condensing)
Electrical Ratings
Voltage: 2030 VAC
Running current:0.021.0 A,
50/60 Hz
Install the thermostat about 5 feet (1.5 m) above the floor in an
area with good air circulation at average temperature.
Do not install in locations where the thermostat can be affected by:
Drafts or dead spots behind doors and in corners
Hot or cold air from ducts
Sunlight or radiant heat from appliances
Concealed pipes or chimneys
Unheated/uncooled areas such as an outside wall behind the
thermostat
NO
NO
NO
Installation tips
Product application
This thermostat provides electronic control of 24 VAC single-stage heating
and cooling systems.