Manual

T8401C ELECTRONIC THERMOSTATS
69-1483—1 2
Fig. 2. Typical location of thermostat.
This thermostat is a precision instrument and was
carefully adjusted at the factory. Handle it carefully.
Mounting Wallplate to Wall
IMPORTANT
Level only for appearance. The thermostat func-
tions normally even when not level.
Mount wallplate, T8401C, and the screws provided (see
Fig. 3) as follows:
1. Place the wallplate at the desired location on the
wall.
2. Pull the thermostat wire through the wallplate
entrance hole.
3. Select the two mounting holes that best fit the
application.
4. Fasten the wallplate to the wall using the anchors
and screws provided.
5. After wiring the wallplate, plug the hole to prevent
drafts from affecting the thermostat; see Wiring
section
.
Fig. 3. Mounting wallplate to wall.
Table 2. Zone Panel Cross Reference.
TotalZone
(TZ-3)
MABS EZ
(EZ-2, EZ-4)
Mini Zone
(MM - 2, -3) MABS II, IIL
Independent
Zone
T8401C1031 Yes Yes One Oher One Oher
Yes N o Yes No No
5 FEET
[1.5 METERS]
YES
NO
NO
NO
M11338
M12202A
WALL
WALL
ANCHORS (2)
WALLPLATE
WHEN USING WALL ANCHORS, DRILL 3/16 INCH
HOLES FOR DRYWALL, 7/32 INCH HOLES FOR
PLASTER OR WOOD.
MOUNTING
SCREWS (2)
1
1