Air Coolers Portable Evaporative Air Cooler User Manual Read and save these instructions before use Scan here: www.honeywellaircoolers.com www.honeywellaircoolers.com E-mail: info@honeywellaircoolers.
PARTS DESCRIPTION (1) (10) (2) (3) (4) (9) (5) (11) (6) (8) (7) 1) 2) 3) 4) 5) Remote Control Remote Control Receptor Control Panel Handle Louvers 6) Water Level Indicator with Light 7) Detachable Water Tank 8) Castors 9) Rear Grill 10) Power Cord Inlet 11) Power Adapter & Cord WARNING -- READ AND SAVE THE AIR COOLER SAFETY & MAINTENANCE GUIDE AND USER MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY DAMAGE AND/ OR IMPAIR ITS OPERATION AND VOID THE WARRANTY.
USE & OPERATION (CONTINUED) FUNCTION BUTTONS POWER Connect the power adapter to the cooler and to the electrical outlet. Press the button to turn the unit on. The cooler will start automatically at low speed. To turn the unit off, press the button again. COOL Press the button to select Cool mode. Please make sure the water tank is filled with water above the minimum level mark. Pressing the COOL indicator light on the display screen activates evaporative cooling.
USE & OPERATION (CONTINUED) REMOTE CONTROL Power Fan Speed Swing Cool Timer QuietSleepTM / TurboBlastTM : ON / OFF : Low / Medium / High / Auto : Controls the motion of the louvers : Evaporative cooling on/off : Controls the Timer function for automatic off : QuietSleepTM / TurboBlastTMmode Note: • The remote control requires a CR2032 (1 x 3V) coin type or equivalent battery for replacement. • Open the battery compartment at the back of the remote control and insert the battery inside.
USE & OPERATION (CONTINUED) FILLING WITH WATER & ICE CAUTION: Remove the power adapter and cord from the unit and the electrical outlet before emptying or refilling the water tank. Wait for 2 minutes before removing the Water Tank to allow any excess water in the Honeycomb Cooling Media to drip into the tank before removing it. Note: After removing the tank, water from the Honeycombmay continue to drip and collect in the tank compartment. Simply wipe dry with a clean, dry cloth. Slide out the Water Tank.
USE & OPERATION (CONTINUED) LOW WATER ALARM* The unit is equipped with a low water sensor. In Cooling Mode, when water in the tank is below the minimum level, you will hear a beeping sound and the indicator light will flash continuously. The unit will automatically pause evaporative cooling. Refill the water tank to deactivate the alarm in cooling mode. First switch OFF the unit and unplug from the power outlet. Fill the water tank with water above the minimum water level mark. Plug in and switch ON again.
USE & OPERATION (CONTINUED) CLEANING THE CARBON DUST FILTER* AND HONEYCOMB COOLING MEDIA WARNING: Before cleaning the unit, switch the unit OFF and disconnect the power adapter from the unit and electrical socket. • The appliance is supplied with a Carbon Dust Filter* and Honeycomb Cooling Media. • The Carbon Dust Filter* and Honeycomb Cooling Media are located inside the Rear Grill. See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance.
TECHNICAL SPECIFICATIONS Model ES800 Cooler DC 24V, 1.5A Adaptor Input 100V-240V, 50 /60 hz, 1.5A Adaptor Output 24V, 1.5A, Class II Wattage 36 W Water Tank Capacity 7 Litres / 1.8 Gallon Cooling Media Honeycomb 250 (W) x 316 (D) x 733 (H) mm 9.8 (W) x 12.4 (D) x 28.9 (H) in Product Dimension Net Weight 5.3 kg / 11.
JMATEK Limited Manulife Financial Centre, Kwun Tong, Hong Kong Phone: 852-2559-5522 Email: info@jmatek.com Web: www.jmatek.com Made in China © 2016 JMATEK Limited. All rights reserved. The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representations or warranties with respect to this product. This product is manufactured by JMATEK Limited.