Installation Instructions

Power up and bind a Mixing Valve
Controller (HM80)
A Mixing Valve Controller should only be fitted by a qualified
fitter. Unless you’re using the evohome Controller as a sensor,
you need to install a sensor (HCW82, HCF82 or DTS92)
before binding the controller to the evohome Controller.
To bind the Digital Room
Temperature Sensor (DTS92)
1
Press and hold the power button for 2
seconds to put the unit into standby
2
Press the up and down arrows together for
three seconds – it should say INst
3
Press the down arrow – it should say COnt
4
Press the up arrow three times – it should say CLr
5
Press the power button once to clear
any previous binding data
6
Press the up arrow – it should say COnt
7
Press the power button once to send the
binding signal to the evohome Controller
8
You should receive a SUCCESS message on the
evohome Controller (if not go back and re-bind)
CONTINUED ON NEXT PAGE
If you are NOT
following GUIDED
CONFIGURATION
follow these steps
on your evohome
Controller display
once the Mixing Valve
Controller and sensor
have been installed:
1. On the evohome
Controller press and
hold “Settings”
for
3 seconds
2. Press the green tick
3. Select ADD A ZONE
4. Select the zone you’re
adding the controller
to then select MIXING
VALVE
5. If you want to control
the zone temperature
with your evohome
Controller (the
evohome Controller
needs to be located
in that zone) YES,
otherwise press NO
and bind the sensor.
evohome
Controller
HOLD
3 SEC
2
Mixing Valve Controller (HM80)
27evohome Installation Guide