Installation Instructions

Power up and bind an Underfloor Heating
Controller (HCE80 or HCC80)
If you want to control the zone temperature with your
evohome Controller (the evohome Controller needs
to be located in that zone) press YES, otherwise press
NO and bind a sensor – either Digital Room Thermostat
(DTS92) or Room Temperature Sensor (HCW82/HCF82).
To bind the Digital Room
Temperature Sensor (DTS92)
1
Press and hold the power button for 2
seconds to put the unit into standby
2
Press the up and down arrows together for
three seconds – it should say INst
3
Press the down arrow – it should say COnt
4
Press the up arrow three times – it should say CLr
5
Press the power button once to clear
any previous binding data
6
Press the up arrow – it should say COnt
7
Press the power button once to send the
binding signal to the evohome Controller
8
You should receive a SUCCESS message on the
evohome Controller (if not go back and re-bind)
Make sure the zone
you’re adding on the
evohome Controller
corresponds to the
correct underfloor
heating zone.
!
If you are NOT
following GUIDED
CONFIGURATION
follow these steps
on your evohome
Controller display once
the underfloor heating
controller and sensors
have been fitted:
1. On the evohome
Controller press and
hold “Settings”
for
3 seconds
2. Press the green tick
3. Press ADD A ZONE
4. Press the zone
you’re adding the
controller to then
select UNDERFLOOR
HEATING
5. You need to install
a sensor (HCW82,
HCF82, DTS92) in
each zone controlled
by the underfloor
heating controller
and bind it to the
evohome Controller.
You need to repeat this
process for every zone
that uses underfloor
heating.
evohome
Controller
HOLD
3 SEC
2
Underfloor Heating Controller (HCE80 or HCC80)
24 Step 3: Power up and bind devices