Installation Instructions

6 Step 1: Wire up the heating system
Wireless Cylinder Thermostat (CS92) continued
To fit the CS92 Insertion Sensor
1
Fit in the cylinder immersion well with suitable fittings to
provide strain relief and prevent accidental removal
2
If the sensor doesn’t fit tightly in the immersion
well fill the space with heat-conductive compound
to ensure maximum heat transfer
3
Install the CS92 Transceiver in a suitable location
close enough for the cable from the sensor to reach
4
Connect the cable from the sensor to the CS92 Transceiver.
The wires are polarity free, so can be connected
in any order. Provide appropriate strain relief
to this end of the sensor cable as well.
If this sensor is used in
an unvented hot water
storage application, the
cylinder manufacturer’s
instructions must be
followed to ensure
compliance with all
safety regulations.
If in doubt, contact the
cylinder manufacturer.
!
4
Wire to CS92 Transceiver
A x B Cy
A x B Cy