F300E Series Install Instructions

SPECIFICATION
DATA
Temperature Rating
Operating Ambient:
40° to 125°F (4° to 52°C).
Temperature of Airow Through Cells:
40° to 125°F (4° to 52°C).
Maximum Cell Washing Temperature:
220°F (140°C).
Storage and Shipping Ambient:
-40°F to +140°F (-40°C to +60°C).
Electrical Ratings
Voltage and Frequency:
Models available for 120V, 60 Hz., 240V, 60Hz.
120V models can be converted in the eld to
240V, 60 Hz or 220/240V, 50 Hz with the 203365A
Conversion Kit.
Power Consumption:
One cell models: 22 W maximum
Two cell models: 36 W maximum.
Current Draw: See Table 2.
Ionizer Voltage: 8150 Vdc.
Collector Voltage: 4075 Vdc.
Table 6. Current Draw
Size
No.
Cells
Max Current (A)
in. mm 120V 220/240V
16 x 25 406 x 635 2 0.4 0.2
20 x 25 508 x 635 2 0.4 0.2
16 x 20 406 x 508 2 0.4 0.2
20 x 20 508 x 508 2 0.4 0.2
20 x 12-1/2 508 x 318 1 0.4 0.2
Mounting
Mounts in any position in the return air duct, usually
next to the furnace blower compartment. Cabinet
is sturdy enough to support weight of a residential
furnace and evaporator coil.
Approvals
Underwriters Laboratories, Inc.: File E30954.
Accessories
203365A Conversion Kit for changing 120V, 60 Hz
power supply to 240V, 60 Hz or 220/240V, 50 Hz.
Repair Parts
See Replacement Parts/Exploded View section.
F300 Electronic Air Cleaner 68-0240EF—09 15