User`s guide
6 
Cable Installation and Removal 
Installation 
1.  Insert the cable’s modular connector into the socket on the imager. 
2.  Pull gently on the cable strain relief to ensure the cable is installed. 
Note:  If the cable is not fully latched, the imager may power intermittently.
Figure 3. Installing the Cable 
Removal 
Turn the host power off and disconnect the power supply from the cable before 
attempting to disconnect the cable from the imager. 
1.  Locate the small pinhole on the imager near the cable connection point. 
2.  Bend a paperclip into the shape shown below. 
3.  Insert the paperclip into the pinhole and apply pressure to release the 
connector lock.  
4.  Pull gently on the strain-relief of the cable to remove the cable from the 
imager. 
Figure 4. Disconnecting the Cable 
MS7580-124-EAS Model Note 
See page 35 for additional cable installation/removal instructions specific to the 
MS7580-124-EAS Genesis with integrated RF EAS antenna. 