Datasheet

Limit and Enclosed Switches
GLE
EN 50047 Compatible
3 Conduit Metal
standard
A22 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1F1-815-235-6847 International 1 1-800-737-3360 Canada
Technical Data
Mechanical life up to 15 million
operations
Degree of protection IP 66
NEMA/UL
type 1, 4, 12, 13
Temperature range Operating:
–25°C to +85°C
–13°F to +185°F
Storage:
–40°C to +85°C
–40°F to +185°F
Approvals IEC 947-5-1
EN60947-5-1
AC15 A300
DC13 Q300
UL & CSA
Vibration (Actuator
not fitted)
10 g conforming to
IEC 68-2-6
Shock (Actuator
not fitted)
50 g conforming to
IEC 68-2-27
Terminal marking to
EN 50013
Snap-Action Contacts
Circuit closed
* Positive opening to IEC 947-5-1-3
Slow-Action Contacts
BREAK BEFORE MAKE
(F.P.) 0°
(O.P.) 26°
(R.P.) 14,5°
(D.T.) 11,5°
(*) 54°
(O.T.) 61° to
75°
(F.P.) 0°
(O.P.) 26°
(R.P.)
(D.T.)
(O.P.2) 39°
(O.T.) 61° to
75°
* Point from which the positive opening is assured.
01 03
X
Ordering:
GLE X XX
Example: GLE B 01 B
Conduit Thread
A
= 1/2N NPT adapter
B
= PG 13,5
C
= 20 mm
D
= PF 1/2