Installation Instructions

5
Section 6: HR80UK Radiator Controller
Caution!
!
When selecting the operating site of the HR80UK ensure that the dis-
tance to other wireless devices such as wireless headphones, cordless
phones etc. is at least 1-2m.
The HR80UK Radiator Controller provides local room temperature control based upon
setpoint information received from the CM67z Room Unit and sends Load Demand
signals based upon room conditions to the HC60NG Relay Module. Setpoints can be
temporarily overridden using the adjustment dial.
The HR80UK can be fitted onto Honeywell VT15, VT117, VT200 and many other manu
-
facturers TRV bodies with a M30x1.5mm thread and a 12.9 - 10.5 mm valve closing point,
adaptors may be available for manufacturers with non standard connections. For more
information contact Honeywell Technical Help Desk, details on the back page.
In the standard CM Zone Pack the HR80UK
Radiator Controllers are pre-bound to each zone as indicated by the zone number label.
To add additional HR80UK Radiator Controllers to a zone refer to Section 8: Changing the Configuration.
Turn the locking knob
a
and separate
the operating
module
from the
coupling
module.
a
1
Turn the coupling module wheel
a
anti-
clockwise (approx. 3 rotations) until the
nose
b
reaches the end stop
c
.
a
c
b
Fit the operating
module
onto the cou-
pling module and turn the locking knob
a
down to lock in place.
1
a
Install batteries into the operating
module
.
Note: Check correct polarity.
Fit the coupling module
a
to the TRV
body
b
and tighten by hand.
For Adaptors see below.
a
b
1 2 3
4 5
Note: Zone number label
a b c d e f g
When adaption is complete the room
temperature set-point is displayed.
6
HR80UK Radiator Controller
A selection of adaptors are available to suit many other TRV manufacturers. For more information please contact Honeywell
Technical Help Desk, details on the back page.