Operation Manual

Connecting devices (binding)20
Cancelling the assignment of a room
setpoint generator/sensor of a zone
1
Keep the installation button pressed
for at least 2 seconds in order to
access the installation mode.
The
l LED lights up. The LED
of zone 1 flashes green.
2
Press the installation button
repeatedly until the LED of the zone
to be removed flashes red.
3
Keep the Mode button pressed
for at least 4 seconds.
The LED of the selected
zone extinguishes.
The assignment of the room setpoint
generator/sensor has been cancelled.
Cancelling the assignment of the time
program (room setpoint) of a zone
1
Keep the installation button pressed
for at least 2 seconds in order to
access the installation mode.
The
LED lights up. The LED
of zone 1 flashes green.
2
Press the installation button
repeatedly until the LED of the zone
to be removed flashes green.
3
Keep the Mode button pressed
for at least 4 seconds.
The LED of the selected
zone extinguishes.
The assignment of the time program
(room setpoint) has been cancelled.
Cancelling the assignment of zones (rooms)