Operation Manual

Rev 1.01 18 900.0355
01/06
Troubleshooting
If this happens … Try this …
No power / LED not
lit
Check the power connections.
Verify that the power supply is
working. (Use a camera that is
known to be good.)
No video Check power connections.
Check BNC connections. (Use a
camera that is known to be
good.)
Check the lens. Remove the
lens. If video is present, the lens
is the source of problem.
Power applied but
picture is black
DC Iris. Check that the Auto Iris
lens selector switch is set to DC.
Increase DC level.
Check wiring connections.
Manual Iris. Check that iris is not
closed.
Video iris Verify that Auto Iris lens selector
switch is set to AI. Increase level
on lens.
Check wiring conditions.
Try lens on another camera or
known good lens on camera.
Dark picture Check lens iris.
Check coax termination is 75 Ω.
Picture noise /
grainy during
daylight operation
Verify lens iris level with AGC
function disabled.
Picture too bright Manual Iris. Switch AES ON.
DC Iris. Switch AI ON, adjust
ALC.
Video Iris. Switch AI ON, reduce
level on lens.
Picture not sharp
(out of focus)
Adjust focus on lens.
Adjust back focus.
Picture goes soft
(out of focus) in low
light
Adjust focus under low light
conditions or use a neutral density
filter under normal lighting
conditions.
Camera roll When operating 12 VDC, set Line
Lock (LL) switch to INT (Internal).