38kW Home Standby Generator Spec Sheet

HT
4 www.honeywellgenerators .com
35 kW
LIQUID-COOLED GENERATOR SETS
CONTROL FEATURES
• 2-Line Plain Text LCD Display Simple user interface for ease of operation
• Mode Switch
-Auto Automatic Start on Utility failure. 7 day
exerciser
-Off Stops unit. Power is removed. Control and
charger still operate.
-Manual/Test (start) Start with starter control, unit stays on. If
utility fails, transfer to load takes place.
• Programmable start delay between 10-30 seconds Standard
• Engine Start Sequence Cyclic cranking: 16 sec. on, 7 rest (90 sec.
maximum duration)
• Engine Warm-up 5 seconds
• Engine Cool-Down 1 minute
• Starter Lock-out Starter cannot re-engage until 5 sec. after
engine has stopped.
• Smart Battery Charger Standard
• Automatic Voltage Regulation with Over and Under
Voltage Protection
Standard
Interconnections
• Automatic Low Oil Pressure Shutdown Standard
Overspeed Shutdown
• High Temperature Shutdown Standard
• Overcrank Protection Standard
• Safety Fused Standard
• Failure to Transfer Protectio Standard
• Low Battery Protection Standard
• 50 Event Run Log Standard
• Future Set Capable Exerciser Standard
• Incorrect Wiring Protection Standard
• Internal Fault Protection Standard
• Common External Fault Capability Standard
• Governor Failure Protection Standard
Single and three phase connections may vary , refer to the owner’s manual for specic connection information.