Datasheet

Honeywell HumidIcon™ Digital
Humidity/Temperature Sensors:
HIH6130/6131 Series
Sensing and Control
GENERAL INFORMATION
The following associated literature is available on the Web:
Product data sheet
Product application note
Application sheets:
Humidity Sensor Performance Characteristics
Humidity Sensor Theory and Behavior
Humidity Sensor Moisture and Psychrometrics
Humidity Sensor Chemical Resistivity
Thermoset Polymer-based Capacitive Sensors
Technical Notes:
I
2
C Communication with the Honeywell HumidIcon™
Digital Humidity/Temperature Sensors
Using Alarms on the Honeywell HumidIcon™ Digital
Humidity/Temperature Sensors
Entering and Using Command Mode on the Honeywell
HumidIcon™ Digital Humidity/Temperature Sensors
Total Error Band Specification for Honeywell Digital
Humidity/Temperature Sensors
CAUTION
IMPROPER HANDLING
Do not remove the sensor from its original protective
packaging until it is ready to be installed.
Do not touch the sensor surface. Use latex finger cots.
Handle the sensor by its package edges or leads.
Do not allow objects to enter the cavity of the sensor
element.
Do not allow debris or contaminants to accumulate on
the filter.
Failure to comply with these instructions may result in
product damage.
SOLDERING AND ASSEMBLY
CAUTION
IMPROPER CLEANING
Insert and solder the sensor after the PCB cleaning
process.
Failure to comply with these instructions may result in
product damage.
CAUTION
IMPROPER SENSOR POSITIONING
Position the sensor so that its face is exposed to the
atmosphere being monitored.
Failure to comply with these instructions may result in
product damage.
CAUTION
IMPROPER SOLDERING
For better product reliability, the HIH6130/6131 Series is
factory-shipped with a protective tape on the cover
(sensing face). This tape must remain in place during
soldering.
After soldering, remove the protective tape as described
below to activate the sensor.
Failure to comply with these instructions may result in
product damage.
PROTECTIVE TAPE REMOVAL
1. Use proper ESD protection.
2. Using covered fingers or tweezers to ensure that no debris
falls into the filter, sensor cover or die, grip the
overhanging front edge of the protective tape and peel it
back from the top surface of the sensor.
3. Ensure the complete rectangle of protective tape is
removed.
Figure 1. Protective Tape Removal
SOLDERING
Process
Automated: Use a no-clean flux. Limit the contact of the
flux to the leads only. Reflow soldering profile is specified
by J-STD-020D for a small package with a peak
temperature of 260 C [500 F].
Manual: Do not exceed 350 C [662 F] for 4 s max.